Chapter 3, Problem 39R
To determine
Explain exemptions of the GFCI protection for receptacle outlets installed in unfinished basements.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Determine the minimum number of cubic inches required for two 10 AWG conductors passing through a box, four 14 AWG conductors spliced in the box, two 12 AWG conductors terminating to a receptacle, and one 12 AWG equipment bonding jumper from the receptacle to the box.
What is the estimated demand load for general lighting and general-use receptacles in a 24-room motel, where each unit has an area of 700 square feet?
You are asked to replace an ungrounded receptacle (two wire) and there is not a source of ground available.
1. It is permissible to replace the receptacle with a GFCI receptacle?
2. If so, how must the receptacle plate be marked.
Be sure and cite code references.
Chapter 3 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 3 - Prob. 1RCh. 3 - How are branch circuits rated? See NEC 210.3._____Ch. 3 - Prob. 3RCh. 3 - Prob. 4RCh. 3 - What spaces are not included in the floor area...Ch. 3 - What is the unit load per square foot for dwelling...Ch. 3 - According to NEC 210.50(C), a laundry equipment...Ch. 3 - How is the total load in volt-amperes for lighting...Ch. 3 - How is the total lighting load in amperes...Ch. 3 - How is the required number of branch circuits...
Ch. 3 - What is the minimum number of 15-ampere lighting...Ch. 3 - How many lighting branch circuits are provided in...Ch. 3 - Prob. 13RCh. 3 - How is the load determined for outlets supplying...Ch. 3 - What type of circuits must be provided for...Ch. 3 - Prob. 16RCh. 3 - In a single-family dwelling, how is overcurrent...Ch. 3 - Prob. 18RCh. 3 - The minimum number of outdoor receptacles for a...Ch. 3 - The Code indicates the rooms in a dwelling that...Ch. 3 - Prob. 21RCh. 3 - Prob. 22RCh. 3 - Prob. 23RCh. 3 - Prob. 24RCh. 3 - Prob. 25RCh. 3 - Although the Code contains many exceptions to the...Ch. 3 - The rating of a branch circuit is based on (Circle...Ch. 3 - a. A 25-ampere branch-circuit conductor is derated...Ch. 3 - Prob. 29RCh. 3 - Prob. 30RCh. 3 - Prob. 31RCh. 3 - Prob. 32RCh. 3 - A split-level home has one stairway that has six...Ch. 3 - Prob. 34RCh. 3 - Prob. 35RCh. 3 - Prob. 36RCh. 3 - In the past, it was common practice to connect the...Ch. 3 - If a residence has two bathrooms, the Code states:...Ch. 3 - Prob. 39RCh. 3 - Prob. 40RCh. 3 - Prob. 41RCh. 3 - Prob. 42RCh. 3 - Prob. 43R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- a. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to connect a receptacle in a dining room to one of the kitchen small-appliance circuits? _______________ What Code section applies to this situation? _______________ b. Are outdoor weatherproof receptacles permitted to be connected to a 20-ampere small-appliance circuit? _______________ c. Receptacles located above the countertops in the kitchen must be supplied by at least _______________ 20-ampere small-appliance circuits.arrow_forwardWhere must GFCI receptacles be installed in residential garages?arrow_forwardA Type NM cable carries a branch circuit to the outside of a building, where it terminates in a metal weatherproof junction box. From this box, a short length of EMT is installed upward to another metal weatherproof junction box on which is attached a cluster of outdoor floodlights. The first box is located approximately 24 in. (600 mm) above the ground. To Meet Code, do the metal boxes and metal raceway have to be grounded? Yes _______________ No _______________ NEC _______________.arrow_forward
- _______ type receptacles must be installed on all 15- and 20-ampere branch circuits except for replacement receptacles as permitted by 406.4(D). Select one: a. AFCI b. GFCI c. Duplex d. Groundingarrow_forwardWhat's the general lighting and general-use receptacle demand load for a 24-room motel where each unit is 700 sq ft?arrow_forwardTrue or False: Receptacles used on the job site should be protected with a GFCI.arrow_forward
- Is a GFCI receptacle permitted be installed as a replacement in an old installation where the 2-wire circuit has no equipment grounding conductor? _________________arrow_forwardAnswer the queations in the attached photo. Thank youarrow_forwardPlans require the installation of surface-mounted fluorescent luminaires on the ceiling of a recreation room that is finished with low-density ceiling fiberboard. What sort of mark would you look for on the label of the luminaire? ________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________arrow_forward
- When installing GFCI and AFCI circuit breakers in a panelboard, it is permissible to connect them to a multiwire branch circuit. (True) (False). (Circle the correct answer.)arrow_forward18. Which of the following would help avoid the choke effect in grounding electrode conductors?A. Installing a main bonding jumperB. Using an approved polyvinyl chloride conduitC. Applying solder to the connectionD. Using bonding bushes on the ends of the racewayarrow_forwardwhen calculating a dwelling lighting load on the "volt-ampere per ft2" basis, the receptacle load used for floor lamps, table lamps, and so fourtharrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning