Plans require the installation of surface-mounted fluorescent luminaires on the ceiling of a recreation room that is finished with low-density ceiling fiberboard. What sort of mark would you look for on the label of the luminaire? ________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
Trending nowThis is a popular solution!
Chapter 7 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Additional Engineering Textbook Solutions
Electrical Engineering: Principles & Applications (7th Edition)
Fundamentals of Electric Circuits
Electric Circuits (10th Edition)
Electric Circuits. (11th Edition)
Electric Motors and Control Systems
Loose Leaf for Engineering Circuit Analysis Format: Loose-leaf
- The recessed fluorescent luminaires installed in the ceiling of the recreation room of this residence are connected with trade size flexible metal conduit. These flexible connections are commonly referred to as fixture whips. Does the flexible metal conduit provide adequate grounding for the luminaires, or must a separate equipment grounding conductor be installed? ________________arrow_forwarda. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to connect a receptacle in a dining room to one of the kitchen small-appliance circuits? _______________ What Code section applies to this situation? _______________ b. Are outdoor weatherproof receptacles permitted to be connected to a 20-ampere small-appliance circuit? _______________ c. Receptacles located above the countertops in the kitchen must be supplied by at least _______________ 20-ampere small-appliance circuits.arrow_forwardThe junction box that will be installed above the dropped ceiling near the fluorescent luminaires closest to the stairway will have ____________ (number of) 14 AWG conductors.arrow_forward
- Refer to the specifications in the back of this text following Chapter 33. a. What electrical codes must be conformed to? ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ b. What is the wiring method to be used in the workshop? ________________________________________________________________________ c. What size conductors are to be used for the lighting branch circuits? ______________________ AWG the small-appliance branch circuits? ______________________ AWG d. What section of the specifications tells us the size of the service entrance to be installed for this residence?arrow_forwardConstruction sites can be dangerous because of the manner in which extension cords, portable electrical tools, and other electrical equipment are used and abused. To reduce this hazard, 590.6(A) of the NEC requires that all 125-volt, single-phase, 15-, 20-, and 30-ampere receptacle outlets used for temporary wiring during construction must be _________________ protected.arrow_forwardAssuming that an outlet box for the entry ceiling has a fixture stud but has external cable clamps, what size box could be installed? Show calculations for both metal and nonmetallic boxes. ___________arrow_forward
- A Type NM cable carries a branch circuit to the outside of a building, where it terminates in a metal weatherproof junction box. From this box, a short length of EMT is installed upward to another metal weatherproof junction box on which is attached a cluster of outdoor floodlights. The first box is located approximately 24 in. (600 mm) above the ground. To Meet Code, do the metal boxes and metal raceway have to be grounded? Yes _______________ No _______________ NEC _______________.arrow_forwardWhere is the main service-entrance panel located in this residence?arrow_forwardWhy is it permissible to omit an electric space heater, water heater, and certain other 240-volt equipment when calculating the neutral service-entrance conductor for a residence? ____arrow_forward
- The NEC requires what type of unique protection for all 120-volt, 15- and 20-ampere branch-circuit outlets in bedrooms of residential homes? In which section of the NEC is this requirement found? _____________________arrow_forwardHow many circuit wires enter the entry ceiling box? How many equipment grounding conductors enter the entry ceiling box?arrow_forwardAssuming all terminals are rated 75 degrees Celsius, you have three (3) #10 AWG THHN/THWN conductors in a conduit and the conduit is run inside an office building, the largest size circuit breaker or fuse permitted to protect this wire?arrow_forward
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT