A Dubosq colorimeter consists of a cell of fixed path length and a cell of variable path length. By adjusting the length of the latter until the transmission through the two cells is the same. the concentration of the second solution can be inferred from that of the former. Suppose that a plantdye of concentration 25 μg dm-3 is added to the fixed cell. the length of which is 1.55 em. Then a solution of the same dye. but of unknown concentration. is added to the second cel l. It is found that the same t ransmittance is obtained when the length of the second cel l is adjusted to 1.18 em. What is the concentration of the second solution?
For a drift length of 200 cm, in a time-of-flight mass spectrometer, what is the difference in arrival time between singly charged ions of m/z 66 and m/z 43 when the accelerating voltage is 3800V?
A 20 ppm solution of a DNA molecule (unknown molecular weight) isolated from Escherichia coli was found to an absorbance of 0.80 in a 2-cm cell. Calculate the absorptivity of the molecule.
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- Calculate the effect that increasing the overpotential from 0.50 V to 0.60 V has on the current density in the electrolysis of 1.0 m NaOH(aq), which is 1.22 mA cm−2 at 0.50 V and 25 °C. Take α = 0.50.arrow_forwardThe molar absorptivity for aqueous solutions of phenol at 211 nm is 6.17 × 103 L cm-1 mol-1. Calculate the permissible range of phenol concentrations if the transmittance is to be less than 85% and greater than 7% when the measurements are made in 1.00-cm cells.arrow_forwardWhat accelerating voltage would be needed to analyze for C6H6+ (MW = 78.11) using a magnetic sector mass spectrometer, if it required 1144V to detect CO2+ (MW = 44.00)?arrow_forward
- Calculate the specific absorbance ratio (SAR), where A620 = 0.136 and A280 = 1.392. Enter your result with 3 decimal places.arrow_forwardIf the concentration of Sn2+ ions in a solution of Sn(OH)2 was measured to be (1.60x10^-3), what is the Ksp value for Sn(OH)2? Note: Your answer is assumed to be reduced to the highest power possible.arrow_forwardAn amino acid on the surface of a protein was labelled covalently with 1.5-I AEDANS and another was labelled covalently with FITC. The fluorescence quantum yield of 1.5-I AEDANS decreased by 10 per cent due to quenching by FITC. What is the distance between the amino acids? (Refer to Table 17G.3 for the appropriate value of R0.)arrow_forward
- 4c. Calculate the values of Mn, Mw, Mz and polydispersity index for a polymer mixture having equivalent moles of two polymers with exact molecular weight being 2,000 Dalton and 10,000 Dalton.arrow_forwardCalculate % transmittance if 85% of light was absorbed by an analyte sample in an UV-Vis spetrophotometric experimentarrow_forwardThe absorbances of solutions containing K2CrO4 in 0.05 M KOH were measured in a 1.0-cm cell of 375 nm. The following results were obtained: Calculate the linear equation of the calibration curve.arrow_forward
- The molar absorptivity for Blue #1 dye is 1.30105 M‒1 ·cm‒1 at 629 nm. Calculate the expected absorbance of solution of Blue #1 with a concentration of 4.50×10–6M when measured at 629 nm in a 1.50 cm cell.arrow_forward5.4.5 Chemical microanalysis5.4.5.1 Exploitation of characteristic X-raysElectron probe microanalysis (EPMA) of bulk samples is now a routine technique for obtaining rapid, accurate analysis of alloys. A small electron probe (100 nm diameter) is used to generate X-rays from a defined area of a polished specimen and the intensity of the various characteristic X-rays measured usingeither wavelength-dispersive spectrometers (WDS) or energy-dispersive spectrometers (EDS). Typically the accuracy of the analysis is š0.1%. One of the limitations of EPMA of bulk samples is that the volume of the sample which contributes to the X-ray signal is relatively independent of the size of theelectron probe, because high-angle elastic scattering of electrons within the sample generates X-rays. The consequence of this is that the spatial resolution of EPMA is no better than ¾2 µm. In the last few years EDX detectors have been interfaced totransmission electron microscopes which are capable of operating…arrow_forwardThe absorbance of a 1.05x10-5 M Fe+3 determined at 580 nm using a 2.50-cm cell was said to be 0.200. What is the molar absorptivity of this solution in liters/mole cm?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning