Question
Book Icon
Chapter 30, Problem 30.6QAP
Interpretation Introduction

Interpretation:

The time taken by the analyte cation to reach the detector needs to be determined, where the osmotic flow rate is given as 0.85mm/s and detector is placed 40cm from the injection end of capillary.

Concept introduction:

The instrumentation needs for capillary electrophoresis includes electric field, cathode and anode compartments which would contain the buffer solution and small vial that contains the sample, capillary tube and detector.

INSTRUMENTAL ANALYSIS-ACCESS >CUSTOM<, Chapter 30, Problem 30.6QAP

Blurred answer
Students have asked these similar questions
A 0.0200 gram blood sample was decomposed by a microwave digestion technique followed by dilution to 100.0 mL in a volumetric flask. Aliquots of the sample solution were treated with a lead complexing reagent and water as follows: Solution 1: 10.0 ml blood sample + 20.0 mL complexing agent + 30.0 mL H20. Solution 2: 10.0 ml blood sample + 20.0 mL complexing agent + 26.0 mL H20 + 4.00 mL of 78 ppb Pb2+ standard. The resulting solutions were analyzed by UV/Vis at 375 nm. Absorbance for solution 1 = 0.155 and for solution 2 = 0.216. Calculate the concentration of lead (ppb) in the original sample.
Lead in dry river sediment was extracted with 25 wt% HNO3 at incubation temperatures for 1 hr. Then 1 mL of filtered extract was combined with other reagents to a total of 4.60 mL. Pb+2 was measured by an electrochemical method by spiking with 2.50 ppm Pb2+. added vol. of 2.50ppm Pb2 signal 0 mL 1.10 0.025 mL 1.66 .050 mL 2.20 .075 mL 2.81 what is Sx based on Sy
An anion has an electrophoretic mobility of -2.50 cm2 /kV · min on a CE system containing a 30 cm long capillary with a detector located 25.0 cm from the point of injection. If the electroosmotic mobility of the buffer is 4.10 cm- /kV · min, and the applied voltage is 15.0 kV, what are the migration time (v) and the apparent mobility (Ha)? O A. 37.5 O B. 31.3 O C. 20.0 O D. 12.2 O E. 26.1
Knowledge Booster
Background pattern image
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Text book image
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:9781285640686
Author:Skoog
Publisher:Cengage
Text book image
Appl Of Ms Excel In Analytical Chemistry
Chemistry
ISBN:9781285686691
Author:Crouch
Publisher:Cengage