(a)
Interpretation:
The name of a laser diffraction instrument, its operation and uses is to be stated.
Concept introduction:
The size of particle is measured by laser diffraction technique. Laser diffraction investigation is utilized here to contrast molecule size dispersions with the help in this case just as discover cycles of progress in estuaries that happen due to various particles. soil and its steadiness when wet.
Answer to Problem 34.15QAP
The instrument Partica LA-950 Laser Diffraction Particle size Distribution Analyzer. is built up by Horiba. Have very close tolerances. It is quite automatic in terms of functioning. The accuracy of the instrument is
Explanation of Solution
There is a instrument in the market developed by the company Horiba named as Partica LA-950 Laser Diffraction Particle size Distribution Analyzer.
The material for which test has to be performed, placed in the sample cell. The two laser beams, depending upon the size of the test sample are scattered at an angle. This angle is proportional to the particle size. The scattered light is detected by the photodiode.
The software which controls the instrument correlates the scattered light with particle size.
The instrument is consisting of
(b)
Interpretation:
The range of particle size which instrument can measure is to be stated.
Concept introduction:
The size of particle is measured by laser diffraction technique. Laser diffraction investigation is utilized here to contrast molecule size dispersions with the help in this case just as discover cycles of progress in estuaries that happen due to various particles. soil and its steadiness when wet.
Answer to Problem 34.15QAP
The instrument can measure particle size from
Explanation of Solution
The instrument has wide range of measurement of particle size. The range of the instrument is
(c)
Interpretation:
The sampling accessories of Partica LA-950 Laser Diffraction Particle size Distribution Analyzeris to be stated.
Concept introduction:
The size of particle is measured by laser diffraction technique.Laser diffraction investigation is utilized here to contrast molecule size dispersions with the help in this case just as discover cycles of progress in estuaries that happen due to various particles. soil and its steadiness when wet.
Answer to Problem 34.15QAP
The instrument has powder jet dry feeder, miniflow and slurry sampler as the accessories.
Explanation of Solution
The sampling accessories are used for preparation of sample. They had pre-defined dimensions of sample like particle size etc. In the Partica LA-950 Laser Diffraction Particle size Distribution Analyzer there are following sampling accessories are available.
- Powder jet dry feeder
- Miniflow
- Slurry sampler
(d)
Interpretation:
The size of the Partica LA-950 Laser Diffraction Particle size Distribution Analyzer is to be stated.
Concept introduction:
The size of particle is measured by laser diffraction technique.Laser diffraction investigation is utilized here to contrast molecule size dispersions with the help in this case just as discover cycles of progress in estuaries that happen due to various particles. soil and its steadiness when wet.
Answer to Problem 34.15QAP
The dimensions of Partica LA-950 Laser Diffraction Particle size Distribution Analyzer is
Explanation of Solution
The size of the instrument is small comparatively.The dimensions of Partica LA-950 Laser Diffraction Particle size Distribution Analyzer is
(e)
Interpretation:
The model used by the software for measurement of particle size is to be stated.
Concept introduction:
The size of particle is measured by laser diffraction technique.Laser diffraction investigation is utilized here to contrast molecule size dispersions with the help in this case just as discover cycles of progress in estuaries that happen due to various particles. soil and its steadiness when wet.
Answer to Problem 34.15QAP
The models followed for analysis of particle size are as mentioned below.
- Mie scattering theory
- Fraunhofer diffraction theory
Explanation of Solution
The software helps to correlate the particle size with the scattering angle. There are numerous models available for analysis of particle size. The Partica LA-950 Laser Diffraction Particle size Distribution Analyzer uses the following two models based on the following theories.
- Mie scattering theory
- Fraunhofer diffraction theory
(f)
Interpretation:
The method of automation of particle size analysis is to be stated.
Concept introduction:
The size of particle is measured by laser diffraction technique.Laser diffraction investigation is utilized here to contrast molecule size dispersions with the help in this case just as discover cycles of progress in estuaries that happen due to various particles soil and its steadiness when wet.
Answer to Problem 34.15QAP
The method of automation of particle size analysis is fully automated.
Explanation of Solution
The automated analysis makes the particle size measurement more accurate. The Partica LA-950 Laser Diffraction Particle size Distribution Analyzer has auto sampler and built in automation. The slurry sampler is also there which is equipped with a robotic arm sampling system. Therefore in this instrument the analysis of particle size is fully automated.
(g)
Interpretation:
The research paper in which technique of laser diffraction is used for determination of particle size is to be stated.
Concept introduction:
The size of particle is measured by laser diffraction technique.Laser diffraction investigation is utilized here to contrast molecule size dispersions with the help in this case just as discover cycles of progress in estuaries that happen due to various particles soil and its steadiness when wet.
Answer to Problem 34.15QAP
In the paper G.Eshel, et al “2 Critical Evaluation of the use of Laser Diffraction for Particle size distribution Analysis” Soil Sci.Soc. Am. J.
Explanation of Solution
The reference of the paper in the literature is given below
G.Eshel, et al “2 Critical Evaluation of the use of Laser Diffraction for Particle size distribution Analysis” Soil Sci.Soc. Am. J.
In this work the relation between the particle size distribution obtained by the combined sieve-pipette method and similar obtained with laser diffraction method was studied. They used Beckam-Coutler LS-230.
Two different particle sizes were analysed. One set has shown good correlation and another set has shown poor correlation.
Want to see more full solutions like this?
Chapter 34 Solutions
Principles of Instrumental Analysis
- (a) Three components in a mixture have varying distribution constants between the mobile phase and the stationary phase. One of the components has a very high distribution constant. Would this component likely elute first or last and how would you design an experiment or modify the components of the separation to make it perform in the opposite manner? (b) One way to dramatically increase the sensitivity of a quadrupole mass spectrometer is to use a technique called selected ion monitoring (SIM). Explain how this technique works and why it improves sensitivity. Explain what dwell time means. Be sure to draw a diagram and describe how this analysis scheme works. Also, is there a compromise between a wide range of masses scanned and SIM? Explain in easy details.arrow_forwardInstrumentation of IR spectroscopy? Please answer at your own words.arrow_forwardWould you use a tungsten or a deuterium lamp as a source of 300-nm radiation?arrow_forward
- What are the advantages of using the KBr in IR spectroscopic sample preparation? Please shortly write at your own words. (4-5 lines maximum ).arrow_forwardWrite the Instrumentation of FT-IR spectroscopy? Please shortly answer at your own words. Answer should be to the point (specific 4-5 lines).arrow_forwardIt is usually recommended to clean the glass surfaces of a refractometer with ethanol or isopropyl alcohol rather than acetone or water. Why?arrow_forward
- When analyzing a selution component by UV-visible spectrophotometry. we prepare solutions with a range of concentrations by serial dilution. Why do we need to analyze a range of solutions? To allow multiple determinations of absorbance at different wavelengths and different concentrations To provide more than one determination of absorbance for a given concentration To see how absorbance varies with concentration To ensure that the linear relationship between absorbarce and concentrasion is velid for a range of concentrations.arrow_forwardAs a forensic toxicologist, you have been given a task on determining amount of cadmium, mercury, chromium, copper and lead metal contents in medicinal herbs using flame atomic absorption spectroscopy (AAS). Hollow cathode lamp (HCL) was selected as radiation source for this analysis. The highest concentration came from lead element followed by chromium and copper, however cadmium and mercury were not detected in the sample. a) Based on your knowledge, conclude whether the above result is valid or not. b) If you are given an option of electrothermal or flame atomizer for above case study, determine which one is suitable and justify your answer.arrow_forwardState the difference between transmittance, absorbance, and molar absorptivity. Which one is proportional to concentration?arrow_forward
- Why is the monochromator not placed after the TCH lamp when performing an absorbance or transmittance measurement in AAS?arrow_forwardGive the rationale behind major steps in the analysis such as blending, filtration, heating of the sample or standard with DNS, dilution, and absorbance measurement.arrow_forwardBriefly compare the advantages and disadvantages of Nujol mulls and KBr pellets for the analysis of solid samples by IR spectrometry.arrow_forward
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningChemistry for Engineering StudentsChemistryISBN:9781285199023Author:Lawrence S. Brown, Tom HolmePublisher:Cengage Learning