Given a 25 hp, three-phase, 230-volt, squirrel cage induction motor. The ambient temperature of the place ofinstallation is 40°C. Use TW wires
A 30- hp squirrel cage induction motor is connected to a 240-volt three phase feeder. The motor is to be replaced with a 50-hp squirrel cage induction motor connected to 480 volts. The motor has a nema code b, a full load current of 49.8 amps, and an sf of 1.10. the present conductors are 3 awg copper with thwn insulation. Are these conductors sufficient to connect to the 50-hp motor or will they have to be replaced
Consider a induction motor (slip-ring) having a three-phase star-connected rotor. When the stator is supplied with rated voltage, slip ring being open circuit, the induced emf value is 65 Volts. The value of 0.6 ohm and 5.5 ohm are the resistance and stand still reactance of rotor per phase. Determine the following:
1. Rotor current per phase when the rotor is at stand still and connected to rheostat of 5.5 ohm (star-connected) and reactance 0.6 ohm per phase.
2. Rotor current per phase when motor is running at slip of 4% while rheostat is short circuited.
Chapter 34 Solutions
Delmar's Standard Textbook Of Electricity
Ch. 34 - Which NEC table is used to determine the full...Ch. 34 - A 5-HP single-phase motor is connected to 208...Ch. 34 - A 10-HP single-phase motor is connected to 240...Ch. 34 - A 75-HP synchronous motor is connected to a...Ch. 34 - A squirrel-cage induction motor has a nameplate...Ch. 34 - A squirrel-cage motor has a nameplate current...Ch. 34 - A 100-HP three-phase squirrel-cage induction motor...Ch. 34 - A 60-HP synchronous motor is connected to 240...Ch. 34 - Prob. 9RQCh. 34 - Both the motors and the feeder in Question 9 are...
Ch. 34 - A 30-HP squirrel-cage induction motor is connected...Ch. 34 - Refer to the preceding Practical Application. When...Ch. 34 - Refer to the first Practical Application in this...Ch. 34 - A 10-HP single-phase motor is connected to 240...Ch. 34 - A 500-HP synchronous motor is connected to 2300...Ch. 34 - A 30-HP three-phase squirrel-cage induction motor...Ch. 34 - A 75-HP synchronous motor is connected to a...Ch. 34 - Prob. 5PPCh. 34 - A 350-HP squirrel-cage induction motor is...Ch. 34 - Three squirrel-cage motors are connected to a...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A 350-HP squirrel-cage induction motor is connected to a 480-volts three-phase feeder. The nameplate lists the following: HP 350, Service factor 1.10, Full-load amps 408, NEMA Code B. The conductors are to be copper with THWN insulation, and 600:5 current transformers are used to reduce the current supplied to the overload heaters. The motor circuit is protected with dual-element time delay fuses. Determine the conductor size, overload heater size using the chart shown in Figure 34-7, the NEMA and IEC starter sizes, and the fuse size for this installation.arrow_forward- Reconnecting Induction Motors 6.a. The voltage in a 460-volt motor is changed to 425 volts. If the original torque was 125 lb-ft, the newtorque isA. 135 lb-ft.B. 117 lb-ft.C. 115 lb-ft.D. 107 lb-ft.6.b. If a 575-volt three-phase motor originally connected in 3-parallel △ is reconnected in 5-parallel Y, thenew voltage isA. 501 volts.B. 794 volts.C. 598 volts.D. 747 volts.arrow_forwardA 460VAC rated, 60 Hz, 125-Hp Three-phase induction type motor is to be connected for across-the-line starting. The nameplate indicates the motor’s maximum ampere rating, 160A. It has a NEMA code letter B. The ambient temp of the installation place is and TW copper will be used. Short-circuit protection device that will be used is Inverse Time Breaker. Calculate the Thermal Overload Protection.arrow_forward
- A 25-horsepower, 230V, 60Hz, 3-phase induction motor has a Nameplate Rating of 58amperes. The nameplate also shows a temperature rise of 30°C. a) Determine the locked rotor current if the motor is Code J.b) Determine the Dual-element, time-delay fuses to be used for the motor’s branch circuit.arrow_forwardA 230VAC rated, 60 Hz, 10-Hp Single-phase AC motor is to be connected for across-the-line starting. Determine its conductor size if the ambient temp 40℃ and RHW copper-clad aluminum will be used.arrow_forwardA 40 hp Squirrel cage Induction-type, 230 volts rated 3 phase motor. It has a code rating of "B" and an ambient temperature of 40 degree celcius. Conductor code RHW copper will be used. Determine its conductor size.arrow_forward
- A 460VAC rated, 60 Hz, 125-Hp Three-phase induction type motor is to be connected for across-the-line starting. The nameplate indicates the motor’s maximum ampere rating, 160A. It has a NEMA code letter B. The ambient temp of the installation place is and TW copper will be used. Short-circuit protection device that will be used is Inverse Time Breaker. Calculate the Motor Starter Size.arrow_forwardA 50-horsepower, 460V, 60Hz, 3-phase induction motor has a Nameplate Rating of 60 amperes. The nameplate also shows a temperature rise of 30°C. Determine the Dual-element, time-delay fuses to be used for the motor’s branch circuit.arrow_forwardThe series winding resistance of the compound generator below is 2 Ohms and the shunt winding resistance is 88 Ohms. If the armature resistance = 0.4 Ohm, the generator voltage and load voltage are 225 Volts and 200 Volts respectively and the generator load is 2 kW, calculate the current flowing in the load.arrow_forward
- A TRIAC phase control circuit has a load resistance of 70 and is powered by an AC source of 155 VRMS. With asymmetrical switching, determine the average load voltage in Volts. Assume α+ = 58 degrees and α- = 65 degrees. Express your answer in three decimal places.arrow_forwardA Y- connected, 10-KVA, 230- has a field winding resistance of 4.59. At an operation of 0.85 lagging power factor, the excitation current is recorded at 10A. the core loss is 300W, and the mechanical loss is 200W. If the corresponding efficiency is 84.9%. calculate the per- phase armature winding resistance.arrow_forward1. What is the use of a synchronous motor in a power system network? Explain in detail with a diagram.(350words)arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Delmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage Learning
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
How Electric Motors Work - 3 phase AC induction motors ac motor; Author: The Engineering Mindset;https://www.youtube.com/watch?v=59HBoIXzX_c;License: Standard Youtube License