(a)
Interpretation:
The maximum uncertainty needs to be calculated, if 1.2-V is digitized with the same three ADCs and input signal is not amplified.
Concept introduction:
Digitization process is defined as conversion of any analog information into a digital form. This digital form can be named as any digitization process of electronic devices and computer systems. The information can be in the form of text, voice, image or sound which is then converted into a binary code. The information in the digitized form is easier to store, transmit or access.
(b)
Interpretation:
Need to calculate maximum uncertainty, if 1.2-V is digitized with the same three ADCs and input signal is amplified by 10 to bring to full scale.
Concept introduction:
Digitization process is defined as conversion of any analog information into a digital form. This digital form can be named as any digitization process of electronic devices and computer systems. The information can be in the form of text, voice, image or sound which is then converted into a binary code. The information in the digitized form is easier to store, transmit or access.
Want to see the full answer?
Check out a sample textbook solution- 10.Which of the following statements regarding double beam spectrophotometers is NOT true? Why? a.The reference beam allows for automatic correction for source intensity fluctuations. b. Comparison of the power emerging from the sample and reference beams determines absorbance and transmittance. c. The reference beam allows for automatic correction for detector drift d. The reference beam is created using a stationary mirror. e. The reference beam is created using a rotating mirror.arrow_forwardExpress the following absorbances (A) in terms of transmittance (T) and percent transmittance (%T) Note that: T = 10-A; %T = T x 100 Show solutionarrow_forwardA solution with a “true” absorbance [A=-log(P0/P)] of 2.10 was placed in a spectrophotometer with a stray light percentage (Ps/P0) of 0.75. What absorbance A' would be measured? What percentage error would result?arrow_forward
- Internal standard. A solution was prepared by mixing 10.00 mL of unknown (X) with 5.00 mL of standard (S) containing 8.24 mg S/mL and diluting to 50.0 mL. The measured signal quotient (signal due to X/signal due to S) was 1.69. In a separate experiment, it was found that, for equal concentrations of X and S, the signal due to X was 0.930 times as intense as the signal due to S. Find the concentration of X in the unknown.arrow_forwardDerive the Scatchard equation for a reaction system 2P + X ↔ P2X, in which only P and P2X have measurable absorbances at the chosen wavelength. Based on this equation and the data given below, determine the values of Keq and ??2? (epsilon P2X). Assume the width of the cuvet used in all of these measurements to be 1cm, i.e., b = 1cm,and the absorbance of the blank solution to be zero. Sample# P0 (M) X0 (M) A 1 4×10-4 0 0.31 2 2×10-4 2×10-2 0.37 3 4×10-4 4×10-2 0.79arrow_forwardCan I have some help with this chart Calculate Absorbance from % Transmittance for each Standard and the Unknown Solution using A = - log T. • Calculate the concentration of each standard based on dilution using C1V1 = C2V2 .arrow_forward
- How to find the signal-to-noise ratio from data given? How many measurements would have to be averaged to obtain a S/N of 500? Explanation for each step will be greatly appreciated.arrow_forwardCalculate the specific absorbance ratio (SAR), where A620 = 0.285 and A280 = 0.795. Enter your result with 3 decimal places.arrow_forwardBelow is given the FT-IR (Fourier Transform Infra Red) data of a 1:1 (by weight) mixture of ethylene carbonate (EC) and dimethyl carbonate (DMC). Absorbance Pis given as a function of wavenumber, m. Regress the above data to a second order polynomial P = a, + a, m+ az m? Find the absorbance at m = 1000 cm-1 Wavenumber, m Absorbance, P (arbitrary unit) ( cm-1) 804.184 0.1591 827.326 0.0439 846.611 0.0050 869.753 0.0073 889.038 0.0448 892.895 0.0649 900.609 0.1204arrow_forward
- What percent transmittance range and what absorbance range are considered to be the optimum working ranges for spectrochemical measurements?arrow_forwardIf two signals differ by 90 Hz in a 300 MHz spectrometer, by how much do they differ in a 500 MHzspectrometer?arrow_forwardAn aqueous solution whose concentration is 0.00356 M was analyzed using spectrophotometer with a molar absorptivity of 412 cm-1 mol-1 L in a cell with a 2.00 cm pathlength. Calculate the absorbance and transmittance for the above solution.arrow_forward
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningChemistry & Chemical ReactivityChemistryISBN:9781337399074Author:John C. Kotz, Paul M. Treichel, John Townsend, David TreichelPublisher:Cengage Learning