A six-pole lap wound armature rotating at 350 rpm is required to generate 260 V. The effective flux per pole is about 0.05 Wb. If the armature has 120 slots, determine the suitable number of conductors per slot and hence determine the actual value of flux required to generate the same voltage
A balanced star-connected load of (8 + j6) Q per phase is connected to a Balanced 3- phase 400-V supply. Find the line current, power factor, power
18/. In a dc machine design, if a wave winding with 8 poles is used, then the parallel path C must be equal to ______.
8
4
2
1
Chapter 9 Solutions
Electrical Transformers and Rotating Machines
Ch. 9 - How does the National Electrical Code specify that...Ch. 9 - An open-delta three-phase transformer system has...Ch. 9 - If a single-phase load is connected across the two...Ch. 9 - Prob. 4RQCh. 9 - A three-phase transformer connection has a...Ch. 9 - A three-phase transformer bank has the secondary...Ch. 9 - A three-phase transformer bank has the primary and...Ch. 9 - Prob. 8RQ
Knowledge Booster
Similar questions
- A three-phase transformer connection has a delta-connected primary and a wye-connected secondary. The center tap of the wye is used as a neutral conductor. If the line-to-line voltage is 480 volts, what is the voltage between any one phase conductor and the neutral conductor?arrow_forwardAn open-delta three-phase transformer system has one transformer center-tapped to provide a neutral for single-phase voltages. If the voltage from line to center tap is 277 volts, what is the high-leg voltage?arrow_forwardA three-phase transformer bank has the secondary connected in a wye configuration. The center tap is used as a neutral conductor. If the voltage across any phase conductor and neutral is 120 volts, how much voltage would be applied to a three-phase load connected to the secondary of this transformer bank?arrow_forward
- A current transformer has a ratio of 600:5. If three loops of wire are wound through the transformer core, how much primary current is required to produce 5 amperes of current in the secondary winding?arrow_forwardIf a single-phase load is connected across the two line conductors and neutral of the transformer in question #2, and one line has a current of 80 amps and the other line has a current of 68 amps, how much current is flowing in the neutral conductor?arrow_forwardIf the secondary of the transformer in question 5 supplies a current of 9.6 amperes to a load, what is the primary current? (Disregard excitation current.)arrow_forward
- Two transformers rated at 100 kVA each are connected in an open-delta connection. What is the total output power that can be supplied by this bank?arrow_forwardA load impedance of 52 Ω is connected to the secondary winding of the transformer in question 3. How much current will flow in the secondary?arrow_forwardAn alternator with a line voltage of 2400 V supplies a delta-connected load. The line current supplied to the load is 40 A. Assuming the load is a balanced three-phase load, what is the impedance of each phase?arrow_forward
- A three-phase transformer bank has the primary and secondary windings connected in a wye configuration. The secondary center tap is being used as a neutral to supply single-phase loads. Will connecting the center-tap connection of the secondary to the center-tap connection of the primary permit the secondary voltage to stay in balance when a single-phase load is added to the secondary?arrow_forwardA current transformer has 4 turns of wire in its primary winding. How many turns of wire are needed in the secondary winding to produce a current of 2 amperes when a current of 60 amperes flows in the primary winding?arrow_forwardAn AC power source is connected across 325 turns of an autotransformer, and the load is connected across 260 turns. What is the turns ratio of this transformer?arrow_forward