Given the following situation, choose the best course of action: measuring 5.0 g of volatile 99% ethanol O in weighing bottle, use analytical balance O in paper box, use analytical balance O in erlenmeyer flask, use top loading balance O in beaker, use triple beam balance
Q: Would the calculated percentage of the hydrate in a sample be too high, too low, or unaffected by…
A: Hello. Since your question has multiple sub-parts, we will solve the first three sub-parts for you.…
Q: Put the steps in order to make 100 mL of 2.00×10-4M from 2.00×10-2 M solution of NaSCN. You have…
A: In order to prepare a 100 mL of 2.00×10-4 M, the given solution, 2.00 ×10-2 M is diluted. First the…
Q: If given the option between using a P1000 and a P200 pipetter to dispense 200 uL, the P200 should be…
A: P1000 pipette measure between 200μl to 1000μl And P200 pipette measure upto 200μl
Q: accuracy of the following instruments: a. analytical balance b. top-loading balance c. serological…
A: Since you have posted a question with multiple sub-parts, we will solve first three sub-parts for…
Q: For each of the following situations, choose the best measuring apparatus that can be used.…
A: The given question discusses about the accuracy of several balance and glasswares in order to make…
Q: 1) determine the glassware that can be used to deliver 4.5mL with an absolute error: a) ≤ 0.15 mL…
A: Answer - Absolute error - The absolute value of the difference between an observed value of a…
Q: What is the primary function of the aeration step in water treatment?
A: Water treatment is such a process which helps in improvement of quality of water and becomes useful…
Q: Using the percent purity calculations, determine the percent yield of synthesis of aspirin.…
A:
Q: why do you calibrate thermometers and pipets?
A: Calibrate means correlate the result with standard instruments reading.
Q: and
A: Given data set; Mass of empty flask = 351.74 g Mass of heated flask = 354.40 g Molar mass of acetone…
Q: This is the laboratory apparatus used for liquid-liquid extraction. Florence flask Volumetric flask…
A: For liquid liquid extraction is extraction of a particular compund from a solution with the help of…
Q: A pycnometer is made of glass, with a close-fitting ground glass stopper with a capillary tube…
A:
Q: Explain two separation techniques how may be feasible for H2O vs Ethanol. One can be an industrial…
A: Separating alcohol from water may be done in a number of different ways. Heating the mixed liquid is…
Q: Which of the below statements IS TRUE/FALSE concerning hot gravity filtration as applied in…
A: 1) If a few crystals form on the filter paper during filtration they can be scraped into a flask and…
Q: Chromatography can be used as a means to purify a reaction product or to analyze a reaction mixture.…
A: Chromatography is a widely used technique for separation of mixture, it is a technique used for…
Q: Given the following situation, choose the best course of action: measuring 500.0 g of distilled…
A:
Q: Which of the satements below is/are limitations of Dumas Method? The Ideal condition is just an…
A: The statements given are,
Q: Carbon tetrachloride is highly combustible * true false O Option 3
A:
Q: Select which of the following is not a feature of carrier gas used in gas chromatography? A. It must…
A:
Q: When answering this problem, report the answer with the appropriate number of significant figures.…
A: Given : Calibration curve equation : y = 21655 x + 0.0318 where y = Absorbance x = molar…
Q: What is the ideal pressure reading (in psia) for a dead weight tester if a 0.25-lb mass is placed in…
A:
Q: The labware we used in Quant Lab is divided into “qualitative” or “quantitative” analytical purpose.…
A: The glassware used in the lab are divided into 2 types that is qualitative and quantitative. As it…
Q: Gas Chromatography can have which of the following stationery phases and/or mobile phases: O A…
A: In gas chromatography there are two phases , stationary phase and mobile phase . Mobile phase is…
Q: Which of the satements below is/are limitations of Dumas Method? i. The Ideal condition is just an…
A:
Q: . The burner gas's composition, as determined by Orsat, is devoid of SO3. true or false
A: Orsat is used to analyse a gas sample .like fuel gas ,burner gas etc
Q: 4. A student performs the HCl tests on the three solid samples as described in Step 5 of Part B and…
A: Explanation:Upon being heated, some substances undergo chemical changes, some undergo physical…
Q: A crucible and its cover weigh 65.82 grams. You add a hydrate of a salt and it now weighs 83.77 g…
A: Given : Weight of crucible + cover = 65.82 gm Weight of hydrated salt in crucible = 83.77 gm…
Q: I got a task in analytical chemistry to calibrate, standardize, verify and validate an analytical…
A: It is said that every location in the world is positioned differently in relation to magnetic…
Q: the injector is kept at higher temperature than the column so that it will move quickly. If the…
A: A multiple choice question based on analytical separations that is to be accomplished.
Q: Make a schematic diagram for the procedure below: A. Constant weighing of the crucibles Bring two…
A: A question based on analytical process that is to be accomplished.
Q: 6. The following are disadvantages of using filter paper in gravimetry, which is not included? а.…
A: 6) c is the correct answer. IN the Gravimetry we uses the ashless filter paper to achieve the…
Q: BaSO4 BaSO4 in (NH4)2SO4
A: This question is related to gravimetric analysis.
Q: Given the following situation, choose the best course of action: measuring 100.0 g of hygroscopic…
A: Concepts: hygroscopic material: such material is one that readily absorbs water (usually from the…
Q: PLEASE ANSWER ALL THE ITEMS. WILL GIVE YOU THUMBS UP AND GOOD RATING TRUE OR FALSE 1. The specific…
A: 1. The specific gravity bottle method can be used for both liquid and solid state. : True 2. The…
Q: TRUE OR FALSE __________ 11. The minimum number of centrifuge tubes in a centrifuge machine during…
A: Since you have posted multiple questions, we will solve first three only. If, you want all the…
Q: A balance high readability is necessarily equated to high accuracy. Select one: a. True b. False…
A:
Q: Caffeine, benzoate, and aspartame content of mountain dew soda was determined using reverse phase…
A: Given: Concentration of standard Caffeine used = 0.70 mg/mL Concentration of standard Benzoate used…
Q: Among the requirements for a substance to be a primary standard is low hygroscopicity. A) True False
A: True. Primary Standard should not absorb moisture from air. A substance that absorb or adsorb water…
Q: set up the chemical equation for combustion ethyl alcohol (C2HO) on 15% excess air . show the masses…
A: Chemical Equation for the combustion of Ethyl alcohol is as under C2H5OH + 3O2 --> 2CO2 + 3H2O…
Q: The amounts reported for the monitored ingredients under internal standard calibration are…
A: FALSE
Q: Hey, Can you pls help me answer all parts of this question(i, ii, iii) ASAP!! which is; (i) Find…
A: Acetylsalicylic acid(C9H8O4) is a monoprotic acid. Hence 1 mole of Acetylsalicylic acid(C9H8O4)…
Q: Suppose Megan needs to transfer 5.00 mL of a liquid with high precision and accuracy. Which of the…
A:
Q: Limitation of accuracy of the following instruments: a. analytical balance b. top-loading balance…
A: “Since you have posted a question with multiple sub-parts, we will solve first three sub-parts for…
Q: Dissolve 1.7 g in a mixture of 2 ml. of nitric acid (-130 g/l) TS and 40 ml of water, and proceed as…
A: The analyst recorded a weight of 1.8652g of sample using an analytical balance.
Q: Please help me there are multiple parts, double check your answer as previous tutors got it wrong.
A: The given illustration is the procedures for the preparation of borax solution.
Q: 1. Discuss the following: a) direct method of weighing b) indirect weighing using the analytical…
A: According to Q&A guidelines of Bartleby, we are supposed to answer only the first question out…
Q: set-up, e volatile acetc е аcet
A: Given data set: Mass of the empty flask = 351.44 g Mass of the heated flask = 355.02 g Thus, Mass of…
Q: the injector is kept at higher temperature than the column so that it will move quickly. If the…
A: In the given problem we have to check whether the given two statements are correct or not in…
Q: Q)What is used for heating small amounts of solids at a high temperature? a) Mortar and pestle b)…
A: Q)What is used for heating small amounts of solids at a high temperature? a) Mortar and pestle b)…
Q: CREATE A SCHEMATIC DIAGRAM USING THE PROCEDURE: Weighing of standard reagents 1. Make an…
A: Chemists use standard reagents to avoid worries about the purity of the chemical compounds. While…
Step by step
Solved in 2 steps with 2 images
- Explain two separation techniques how may be feasible for H2O vs Ethanol. One can be an industrial approach other can be a laboratory-scale method.Choose the one correct or one incorrect statement regarding filtration: gravity filtration uses a Buchner funnel, filtering flask and negative pressure filter paper should be wet with solvent to seal it to the funnel before filtering the solution collected in the filtering flask is called the residue vacuum filtration is most often used to remove impurities from a solution the solution to be filtered should completely fill the top of a Buchner funnelPreparation of 0.25N NaOH Objective: Apparatus and Materials: Procedure : Calculate the exact mass of NaOH needed to prepare 1.0L of 0.25N NaOH for standardization. Show your computations. Using the triple beam balance, weigh the desired amount of NaOH. Place the weighed amount of NaOH into the 500 mL volumetric flask and add distilled water until it reaches the mark. Agitate and transfer the solution into the reagent bottle. Add again distilled water to the same volumetric flask until it reaches the mark and pour it to the same reagent bottle, thus having a total volume of 1.0 L. Label the reagent bottle, 0.25N NaOH. Data and Computations: Conclusion:
- For each of the following situations, choose the best measuring apparatus that can be used. Weighing 18.00 g NaOH Top loading balance analytical balance triple- beam balance Weighing 0.7455 g KCl Top loading balance analytical balance triple- beam balance Measuring exactly 5.00 mL of 0.100 M HCl solution 5ml volumetric piptette 5ml measuring piptette Graduated cylinder Preparing a 10.0-mL 2.00 M NH3 solution 10ml volumetric flask 10ml beaker Graduated cylinderTRUE OR FALSE __________ 11. The minimum number of centrifuge tubes in a centrifuge machine during its operation is one. __________ 12. Never place reagents directly onto the weighing pan of a balance, always use weighing paper, a beaker, or some other container. __________ 13. To transfer a solution, the stirring rod touches the delivery point of the reagent vessel and the wall of the receiving vessel. __________ 14. An open flame is the heat source for heating or evaporating flammable liquids. __________ 15. Most chemicals used in experiments can be discarded into the sink.Design a procedure on how you will prepare 1.25 M table sugar (C12H22O11)solution and 1.25 M table salt (NaCl) solution diluted to 1 L water. Perform three trialseach set-up and get the average. Write/ encode your output in short bond paper withthe following parts:Title____________________I. Objectives:II. Materials:III. Procedure (including pictures/diagrams):IV. Data:V. Generalization:
- In order to carry out a highly accurate determination, usually of a valuable constituent in a material of large bulk such as gold, a chemist will carry out a_______________ Select one: Determination Assay Analysis Assessment Background checkUsing the percent purity calculations, determine the percent yield of synthesis of aspirin. Part I Synthesis of Aspirin Mass of salicylic acid used (g) 2.029g Volume of acetic anhydride used (mL) 5ml Mass of acetic anhydride used (vol. × 1.08 g/mL) 5.4g Mass of aspirin synthesized (g) 3.256g Part II Melting Temperature Data Melting temperature (°C) 133°C Part III Salicylic Acid Standard Stock Solution Initial mass of salicylic acid (g) 0.210g Moles of salicylic acid (mol) 0.0147 mol Initial molarity of salicylic acid (M) 0.724 M Part III Beer’s Law Data for Salicylic Acid Standard Solutions Trial Concentration (M) Absorbance Water (mL) 1 10 0.301 0 2 7.5 0.219 2.5 3 5.0 0.163 5.0 4 2.5 0.074 7.5 Best-fit line equation for the salicylic acid standards Test of the Purity of the Synthesized Aspirin Initial mass of aliquot of product (g)…When answering this problem, report the answer with the appropriate number of significant figures. When entering units, use proper abbreviated units with proper capitalization. A beverage drink mix sample is prepared by mixing a packet of beverage powder in a gallon (3.78 L) of water. A sample for analysis is prepared by diluting 10.00 mL of this solution in a 50.0 mL volumetric flask. When measured using a colorimeter, this diluted solution has an absorbance of 0.349. The calibration curve for the experiment yielded a linear fit of y = 21655x+0.0318 and an R2 value of 0.9911. Determine the molar concentration of food dye in the analyzed sample. Answer: _____x10____ _____units
- I got a task in analytical chemistry to calibrate, standardize, verify and validate an analytical balances, can you help me?A fly ash aerosol of monodisperse particles with a density of 2.0 g/mL and particle diameter of 10.0 mm has a concentration of 1000.0 mg/m3. Calculate the settling velocity in cm/s and the settling rate in g/m2-s. Please answer very soon will give rating surely5.00 mL of stock solution is diluted to 25.00 mL, producing solution ALPHA. 10.00 mL of solution ALPHA is diluted to 25.00 mL, resulting in solution BETA. 10.00 mL of solution BETA is then diluted to 25.00 mL, producing solution GAMMA. dilution factor for ALPHA from stock solution = 0.167 dilution factor for BETA from ALPHA solution = 0.0476 part c and d?