The following 3-phase loads are connected to a 3- phase 400 V, 50 Hz power supply: Load 1: Lighting load of P kW at unity P.F where P = 100 + NN and NN is the last two digits (from right) of your registration number. Load 2: A 3-ph induction motor that draws 400 A at 0.8 lagging power factor. Find: 1- The total line current supplied by the source to feed these loads. 2- The leading power factor of the 300 kW synchronous motor that should be connected in parallel www with these loads in order to to improve the nower factor to be 0 96

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

plz ans it

NN=65

QUESTION 2:
The following 3-phase loads are connected to a 3- phase 400 V, 50 Hz power supply:
Load 1: Lighting load of P kW at unity P.F where P = 100 + NN and NN is the last two digits (from
right) of your registration number.
Load 2: A 3-ph induction motor that draws 400 A at 0.8 lagging power factor.
Find:
1- The total line current supplied by the source to feed these loads.
2- The leading power factor of the 300 kW synchronous motor that should be connected in parallel
with these loads in order to to improve the power factor to be 0.96.
3- The line current supplied by the source to feed these loads after connecting the synchronous motor.
4- Does the synchronous motor supply or consume reactive power in this case of operation. Verify
your answer.
Transcribed Image Text:QUESTION 2: The following 3-phase loads are connected to a 3- phase 400 V, 50 Hz power supply: Load 1: Lighting load of P kW at unity P.F where P = 100 + NN and NN is the last two digits (from right) of your registration number. Load 2: A 3-ph induction motor that draws 400 A at 0.8 lagging power factor. Find: 1- The total line current supplied by the source to feed these loads. 2- The leading power factor of the 300 kW synchronous motor that should be connected in parallel with these loads in order to to improve the power factor to be 0.96. 3- The line current supplied by the source to feed these loads after connecting the synchronous motor. 4- Does the synchronous motor supply or consume reactive power in this case of operation. Verify your answer.
Expert Solution
steps

Step by step

Solved in 2 steps with 3 images

Blurred answer
Knowledge Booster
Magnetically Coupled Circuit
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,