To determine
The value of Vab, Vbc, and Vca for the dots are shown in Figure 10.38.
(b)
To determine
The value Vab, Vbc, and Vca for the dot near c is moved to b in Figure 10.38.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
5.65 Open PowerWorld Simulator case Example 5_10 with the series capacitive compensation at both ends of the line in service. Graph the load bus voltage as a function of load real power (assuming unity power factor at the load). What is the maximum amount of real power that can be transferred to the load at unity power factor if the load voltage is always greater than 0.85 per unit?
How did 2 + j8ohms become 2 + 2 + j8ohms and then 8.9 ∠63.4? Like what did you do and why?
The annual load duration curve of a power supply system may be considered as straight line from 40 MW to 8 MW. The load factor of the system is ?
Chapter 10 Solutions
Power System Analysis and Design (MindTap Course List)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- At the end of the 8 km overhead line given in the figure below, there are two distribution transformers, one of which is 800kVA and the other is 1200kVA, operated with power coefficients of 0.6 and 0.8, respectively. The end-of-line voltage is 6kV. Find the required rated cross section and line head voltage so that the power loss on the line is less than %pk = 10.arrow_forwardDescribe the concept of microgrids and their potential impact on decentralized power generation.arrow_forwardThe open circuit and short circuit impedance of a transmission line are 200 ohm and 50 ohm respectively. What will be the characteristic impedance of the transmission line?arrow_forward
- Two overhead lines AB (Z0 = 500 Ω, length = 300 km, attenuation factor = 0.8) and BC (Z0= 300 Ω, length = 120 km, attenuation factor = 0.9) feed a load of surge impedance 1700Ω at C. A triangular wave of peak height (875)/2 kV and duration 300 µs originates in theoverhead line AB at A and travels towards B. Using Bewley Lattice Diagram, determineand sketch the voltages at A, B and C for the first 2 ms. A to J z0=500 ohm, C to J z0 = 300 ohm B to J z0 = 400 ohm D to J z0 = 50 ohm.arrow_forwardWhat is the need to conduct power flow analysis? Discuss about data needed and bus types too.arrow_forwardDescribe the operation of HVDC (high-voltage direct current) transmission systems. What are the advantages of HVDC over HVAC (high-voltage alternating current) in long-distance power transmission?arrow_forward
- Explain the concept of dynamic line rating (DLR) and its significance in optimizing power transmission capacity.arrow_forwardFor the system in Figure 4 with given generation and load dispatch determine the voltages after two itterations of Gauss-Seidel method. Assume the initial voltage to be 1.01 at angle of 0◦ pu at bus 1, 1.015 at angle of 0◦ pu at bus 2, and 1.0 at angle of 0◦ pu at bus 3. All line impedances are in per unit on a common base, and charging is neglected. Take base power of 100 MVA.arrow_forwardThe figure below shows the one-line diagram of a simple three-bus power system withgeneration at bus 1. The voltage at bus 1 is V1 = 1.0∠0°per unit. The scheduledloads on buses 2 and 3 are marked on the diagram. Line impedances are marked inper unit on a 100 MVA base.(a) Using Gauss-Seidel method and initial estimates of ?2(0) = 1.0 + ?0, ?3(0) = 1.0 + ?0, determine V2and V3. Perform two iterations.(b) If after several iterations the bus voltages converge to?2 = 0.90 − ?0.10 pu?3 = 0.95 − ?0.05 pudetermine the line flows and line losses and the slack bus real and reactive power.arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning