Question
Chapter 10, Problem 10.9QAP
Interpretation Introduction
Interpretation:
The advantages of plasma sources over the flame sources for emission spectrometry needs to be explained.
Concept introduction:
Plasma sources spectroscopy a kind of mass spectrometry that detects metals as well as non-metals of low concentrations as one part in 1015 (part per quadrillion, ppq) on the low-background isotopes that involves plasma. Flame emission spectroscopy is a traditional method of spectroscopy. In this method, quantitative measurement of the optical emission obtained from the stimulated atoms are used to determine the concentration of an element that is to be analyzed.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
DIfference between different types of UV spectrometers based on their advantages and disadvantages
Compare and contrast Flame Emission Spectrophotometry and Atomic Absorption Spectrophotometry
Describe the basic design difference between a spectrometer for absorption measurements and one for emission studies?
Chapter 10 Solutions
INSTRUMENTAL ANALYSIS-ACCESS >CUSTOM<
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- What are the main components of a spectrophotometer? Choose all that applies. radiation source sample compartment/holder monochromator detectorarrow_forwarddetector Answer Bank emission monochromator excitation monochromator light source sample cell ^ex A em It is typically a grating, prism, or filter that selects a narrow wavelength band of radiation and passes it to the sample. It holds the sample and has a defined pathlength. It is typically a photomultiplier tube that generates an electric signal when struck by photons. It is positioned 90° to the incident light and selects a narrow wavelength band of radiation to pass toarrow_forwardAtomic emission spectroscopy and the method of standard addition are used to determine the Na+ concentration and its uncertainty in an unknown sample. Increasing amounts of a 1.75 ug/mL standard Na+ solution are added to a series of volumetric flasks containing 15.00 mL of the unknown solution. The volumetric flasks are then diluted to a final volume of 200.0 mL. Atomic emission spectroscopy is then used to measure the emission intensity of each solution. Unknown volume Standard volume Final volume Emission (mL) (mL) (mL) intensity 15.00 0.00 200.0 351.0 15.00 5.00 200.0 494.0 15.00 10.00 200.0 642.0 15.00 15.00 200.0 807.0 15.00 20.00 200.0 948.0 Based on the data in the table, determine the original concentration of Nat and its uncertainty in the unknown sample. Report the uncertainty with three significant figures. concentration: ug/mL µg/mLarrow_forward
- show-all-working-explaining-detailly-each-step Answer should be typewritten using a computer keyboard.arrow_forwardThe maximum number of spectra that can be recorded per second by ToF-MS is limited by the time taken by the slowest ions to go from the source to the detector. If the slowest ion took 45.6 microsecond to travel, at what frequency could you record spectra if a new extraction cycle were begun each time this heaviest ion reached the detector? 30000 spectra/s 10000 spectra/s 11000 spectra/s 500 spectra/s 22000 spectra/sarrow_forwardWhat is the relationship between the excitation wavelength (λex) and emission wavelength (λem) in atomic spectrophotometry (e.g. flame or furnace atomic absorption spectrophotometry)? Why is this different from molecular spectrophotometry?arrow_forward
- Induction coupled plasma (ICP) emission spectrometry is widely used for the sensitive multi-element determinations. How does the ICP work?arrow_forwardThe equation for the calibration curve prepared with a series of standard Na + solutions (1-5 mg / L) was calculated as y = 43.5x + 11.5. Since the emission intensity of the water sample prepared by diluting 10 times under the same conditions is 80, calculate the Na + concentration of the water sample in mg / L.arrow_forwardThe validation process comprises four main steps that are : hardware validation, software validation, method validation and system suitability. To evaluate a spectrophotometer’s accuracy by measuring absorbance, a solution of 60.06 mg/L K2Cr2O7 in 0.0050M H2SO4 was carefully prepared together with a 0.0050 M H2SO4 as a reagent blank. If the spectrometer’s signal is properly calibrated, it has been reported that this solution should provide an absorbance of 0.640 +- 0.010 at wavelength 350 nm. Which one of the validations mentioned above had been involved in this process? Explain your choicearrow_forward
- Explain why the count rate from the detector straight on from the source is much greater than the detector situated in a 45 degree deflection position.What can be deduced from this observation about the structure of the atom and the properties of the nucleus of goldarrow_forwardBased on the data in the table, determine the original concentration of Na+ and its uncertainty in the unknown sample. Report the uncertainty with three significant figures.arrow_forwardIn a clinical analysis laboratory, the level of sodium in the blood is determined by atomic emission spectrometry. The method uses lithium as an internal standard, since the sample treatment is very complex and can cause ion losses. Also, the lithium signal does not interfere with that of sodium. The table below shows the results obtained after measuring different sodium standards to which a constant concentration of lithium (100 mM) has been added. Na concentration (mM) Na signal (UA) Li signal (UA) 0 0 0,180 20 0,036 0,220 50 0,066 0,160 100 0,125 0,190 150 0,200 0,210 200 0,315 0,250 a) Calculate the calibration line corresponding to the internal standard method. b) A blood sample was analyzed with said method and the following signals were obtained: 0.197 AU for sodium and 0.23 AU for lithium. What was the sodium concentration of the tested blood?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning