Chapter 10, Problem 3RQ
To determine
The size of the fuse for primary overcurrent protection.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A 4-pole shunt generator with wave-wound armature has 41 slots, each having 12 conductors. The armature resistance is 0.05 ohms and shunt field resistance s 200 ohms. The flux per pole is 25 mWb, if a load resistance of 10 ohms is connected across the armature terminals, calculate the voltage across the load when generator is driven at 1000 rpm
A long-shunt compound-wound generator gives 240 volts at F.L. output of 100A. The resistances of various windings of the machine are : armature (including brush contact) 0.1 Q, series field 0.02 Q, inter pole field 0.025 2, shunt field (including regulating 0.2 resistance) 100 2. The iron loss at F.L. is 1000 W; windage and friction losses total 500 W. Calculate F.L. efficiency of the machine.
There is an ambient temperature of 65°C with a temperature rating of the conductor as 75°C. What is the ambient temperature correction factor based on 86°F?
Chapter 10 Solutions
Electrical Transformers and Rotating Machines
Ch. 10 - Prob. 1RQCh. 10 - What size overcurrent device should be used to...Ch. 10 - Prob. 3RQCh. 10 - The secondary of the transformer in question #3...Ch. 10 - A 10 kVA transformer has a primary voltage of 208...Ch. 10 - A 10 kVA transformer has a primary voltage rating...Ch. 10 - What size conductor should be used to connect the...
Knowledge Booster
Similar questions
- A 10 kVA transformer has a primary voltage rating of 240 volts and a secondary voltage rating of 480 volts. The transformer is connected to a circuit protected by a 100 ampere circuit breaker. The secondary is protected by a 25-ampere fuse. Does the primary require separate overcurrent protection?arrow_forwardAn alternator with a line voltage of 2400 V supplies a delta-connected load. The line current supplied to the load is 40 A. Assuming the load is a balanced three-phase load, what is the impedance of each phase?arrow_forwardIf dual-element time delay fuses are to be used as the short circuit protective device, what size fuses should be used to protect the circuit in question #12? Five 5 HP, three-phase motors with NEMA code B are connected to a 240-volt line. The conductors are copper with type THWN insulation. What size conductor should be used to supply all of these motors?arrow_forward
- A 10 kVA transformer has a primary voltage of 208 volts and a secondary voltage of 120 volts. What size circuit breaker should be used to protect the primary winding?arrow_forwardWhat size conductor should be used to connect the primary of the transformer described in question #6? Assume the conductor to be copper with type THW insulation.arrow_forwardTwo transformers rated at 100 kVA each are connected in an open-delta connection. What is the total output power that can be supplied by this bank?arrow_forward
- A 3-phase, 50 Hz, 3000 V motor develops 600 H.P. (447·6 kW), the power factor being 0·75 lagging andthe efficiency 0·93. A bank of capacitors is connected in delta across the supply terminals and powerfactor raised to 0·95 lagging. Each of the capacitance units is built of five similar 600-V capacitors.Determine the capacitance of each capacitor.arrow_forwardA load impedance of 52 Ω is connected to the secondary winding of the transformer in question 3. How much current will flow in the secondary?arrow_forwardIf dual-element time-delay fuses are to be used as the short-circuit protective device, what size fuses should be used to protect the circuit in question #12?arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Electrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage LearningUnderstanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning