Question
Chapter 11, Problem 11.11QAP
Interpretation Introduction
Interpretation:
The process of glow-discharge mass spectrometry and its advantages over other processes needs to be explained.
Concept introduction:
Glow discharge process of atomization for the purpose of analysis in a mass spectrometer is one of the multiple such processes, each with its own capabilities and limits of analysis.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
What are the differences between a mass spectrometer and a IR spectrometer?
Briefly explain the principles of APCI mass spectrometry
What is the difference between mass spectroscopy and mass spectrometry?
Chapter 11 Solutions
Principles of Instrumental Analysis
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- Give an advantage and disadvantage of the spectra obtained from an electron impact(EI) mass spectrometer?arrow_forwardTrue or False 1. Photodiode arrays are devices within the instrument that help amplify the signal of a sample. 2. Atomic spectroscopy requires the atomization of a sample, which involves nebulization and eventually volatilization to form an elemental vapor. 3. Organic compounds are normally analyzed in atomic spectroscopy despite their small electronic transition range.arrow_forwardExplain why the count rate from the detector straight on from the source is much greater than the detector situated in a 45 degree deflection position.What can be deduced from this observation about the structure of the atom and the properties of the nucleus of goldarrow_forward
- How can we use the observed colors to determine quantities and identities of materials? I am highly confused by spectrometry.arrow_forwardIf a TOF mass spectrometer needs to scan an m/z of 600, what is the speed of this ion if it is accelerated through 4000 volts? How long will this ion (at the speed calculated) take to drift 2.00 m through the spectrometer? How many mass spectra can be taken each second if a new cycle begins each time this ion reaches the detector?arrow_forwardWhen LC is coupled with mass spectrometry (MS), what are the advantages (compared to LC only) in terms of analyte identification and quantitation in the sample?arrow_forward
- 2) In a laboratory study, a calibration was performed using NH4C1 to analyze ammonium spectrophotometrically. The results of the study are given below. According to this, when the 5.0 mL sample containing ammonium is completed to 50 mL with pure water, find the amount of NH4 in the sample whose absorbance was found as 0.12 according to the table. (N: 14 g / mol, H: 1 g / mol, Cl: 35.5 g / mol). Concentration (mg/L) Absorbance 0.01 5 0.05 7.5 0.1 10 0.15 12 0.18arrow_forwardThe maximum number of spectra that can be recorded per second by ToF-MS is limited by the time taken by the slowest ions to go from the source to the detector. If the slowest ion took 45.6 microsecond to travel, at what frequency could you record spectra if a new extraction cycle were begun each time this heaviest ion reached the detector? 30000 spectra/s 10000 spectra/s 11000 spectra/s 500 spectra/s 22000 spectra/sarrow_forwardBromine has two naturally occuring isotopes, Br-79 and Br-81, approximately 50% of each. Bromomethane will contain approximately 50% Br-79 and 50% Br-81. The mass spectrum peak for methane containing Br-79 will be referred to as the M+ (molecular ion) peak, and the peak for Br-81 will be called the M+2 peak, as Br-81 weighs two more amu than Br-79. What will be the locations of the two bromomethane peaks on the mass spectrum and what will be the approximate ratio of their heights?arrow_forward
- What are some of the advantages and limitations of mass spectroscopy?arrow_forwardThe mass spectrum of Copper is shown Which species could be responsible for the peak at m/z 32.5?arrow_forwardName two advantages of performing a mass spectrometry imaging experiment at high mass resolution (R.P. > 120000)arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning