Textbook Question
Chapter 11, Problem 4PA
Using the above example, determine the wire size needed for the 400-ampere service in accordance with the National electrical Code. Assume that the conductors have type THWH insulation. (Note: As a general rule, for each 100 feet of conductor length the wire size is increased one standard size because of voltage drop.)
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Assuming copper, standard wire type, and normal temperature rating, what is the typical conductor size (in awg) for a 60A service in the U.S.?
The following problems refer to grounding requirements. Give the source of yourresponses.
1. What is the minimum size copper grounding electrode conductor for a service withthree sets of parallel 350 kcmil conductors (three conductors per phase)?
What is the minimum-size supply-side bonding jumper required if installed on the line side of a 300-ampere service disconnecting means if the service conductors are sized at 400-kcmil copper? a) 3 AWG copper b) 2 AWG copper c) 1/0 AWG copper d) Parallel 2 AWG copper conductors
Chapter 11 Solutions
Delmar's Standard Textbook of Electricity (MindTap Course List)
Ch. 11 - What is the maximum temperature rating of Type...Ch. 11 - 2. Name two types of conductor insulation designed...Ch. 11 - A 10 AWG copper conductor with Type THW insulation...Ch. 11 - 4. Six 1/0 aluminum conductors are to be run in a...Ch. 11 - Name five conditions that must be met for running...Ch. 11 - What is the largest solid (nonstranded) conductor...Ch. 11 - Can Type TW cable be used in an area that has an...Ch. 11 - How is the grounded conductor in a flat...Ch. 11 - What three colors are ungrounded conductors not...Ch. 11 - Twenty-five 12 AWG copper conductors are run in...
Ch. 11 - A single-hase load is located 2800 ft from its...Ch. 11 - It is decided to use parallel 0000 conductors to...Ch. 11 - A three-phase motor operates on 480 V and is...Ch. 11 - You have been hired by a company to connect an...Ch. 11 - 2. You are a journeyman electrician in an...Ch. 11 - You are an electrician working in an industrial...Ch. 11 - Using the above example, determine the wire size...Ch. 11 - 1. A 2 AWG copper conductor is 450 ft long. What...Ch. 11 - 2. An 8 AWG conductor is 500 ft long and has a...Ch. 11 - 3. Three 500-kcmil copper conductors with Type RHH...Ch. 11 - 4. Eight 10 AWG aluminum conductors with Type THWN...Ch. 11 - 5. A three-phase motor is connected to 480 V and...Ch. 11 - 6. A 50-hp DC motor is connected to 250 volts. The...Ch. 11 - 7. A bank of electric heaters has a power rating...Ch. 11 - A 15-hp squirrel-cage induction motor is connected...Ch. 11 - Determine the resistance of a 16 AWG copper...Ch. 11 - Determine the ohms-per-mil-foot of an aluminum...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 4. Eight 10 AWG aluminum conductors with Type THWN insulation are installed in a single conduit. What is the maximum current-carrying capacity of these conductors? Assume an ambient temperature of .arrow_forward14. If the total circular mil area of the largest ungrounded service-entrance conductor for a service is 2000-kcmil copper, what is the minimum size required for a wire-type main bonding jumper for the service? a) 4/0 AWG copper b) 250-kcmil copper c) 350-kcmil copper d) 500-kcmil copper 15. The minimum-size grounded conductor for a service supplied by a grounded system shall not be smaller than the minimum size required for a(n)______. a) Equipment grounding conductor b) System bonding jumper c) Ungrounded conductor d) Grounding-electrode conductor Note: answer both the questions with proper explanation. As per bartleby honor code I can submit 3 questions. So please answer botharrow_forwardwhen calculating a dwelling lighting load on the "volt-ampere per ft2" basis, the receptacle load used for floor lamps, table lamps, and so fourtharrow_forward
- 13. If the largest ungrounded service-entrance conductor for a service is 750-kcmil copper, what is the minimum size required for a wire-type main bonding jumper for the service? a) 2/0 AWG copper b) 1/0 AWG copper c) 3/0 AWG copper d) 1 AWG copper 14. If the total circular mil area of the largest ungrounded service-entrance conductor for a service is 2000-kcmil copper, what is the minimum size required for a wire-type main bonding jumper for the service? a) 4/0 AWG copper b) 250-kcmil copper c) 350-kcmil copper d) 500-kcmil copper 15. The minimum-size grounded conductor for a service supplied by a grounded system shall not be smaller than the minimum size required for a(n)______. a) Equipment grounding conductor b) System bonding jumper c) Ungrounded conductor d) Grounding-electrode conductorarrow_forwardwhat is the minimum size single conductor of copper jacketed mineral insulated cable that can for a consumer's service?arrow_forwarddefine the conductor with examplesarrow_forward
- Describe what the following conductor designation means when it is printed on the insulation; RHH/RHW,USEarrow_forward5. Identify the minimum distance requirements between network cables and power sources and identify types and location for cable supports. Note: Please do not handwritten.arrow_forward5. Identify the minimum distance requirements between network cables and power sources and identify types and location for cable supports.arrow_forward
- Which of the following statements about equipment grounding conductors (EGCs) is true?A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor.B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray.C. No current should be present in the EGC during normal operation.D. EGCs are required to be decreased in size to address voltage drop.arrow_forwardwhat is the receptacle demand load for a 9600 square foot office building with 52 receptaclesarrow_forwardPlease answer the question full sentence 5. Identify the minimum distance requirements between network cables and power sources and identify types and location for cable supports.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Delmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningEBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
Why HIGH VOLTAGE DC power Transmission; Author: ElectroBOOM;https://www.youtube.com/watch?v=DFQG9kuXSxg;License: Standard Youtube License