![EBK THERMODYNAMICS: AN ENGINEERING APPR](https://www.bartleby.com/isbn_cover_images/8220100257056/8220100257056_largeCoverImage.jpg)
EBK THERMODYNAMICS: AN ENGINEERING APPR
8th Edition
ISBN: 8220100257056
Author: CENGEL
Publisher: YUZU
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 11.10, Problem 64P
Devise a refrigeration cycle that works on the reversed Stirling cycle. Also, determine the COP for this cycle.
Expert Solution & Answer
![Check Mark](/static/check-mark.png)
Want to see the full answer?
Check out a sample textbook solution![Blurred answer](/static/blurred-answer.jpg)
Students have asked these similar questions
An ideal refrigeration cycle that has a condenser temperature of 25°C and an evaporator temperature of -25°C. Compute for the work input to the compressor, heat absorbed by the evaporator from the cold space, heat released to the hot space, and the COP of this refrigerator for the working fluid R-410a. Use Sonntag's book for Saturated R-410a's table reference.
An ideal refrigeration cycle that has a condenser temperature of 25°C and an evaporator
temperature of -25°C. Compute for the work input to the compressor, heat absorbed by the
evaporator from the cold space, heat released to the hot space, and the COP of this refrigerator
for the working fluid R-410a.
8 Calculate the COP value for the vapor compression refrigeration cycle where Th=10C and Tc=-20C.
Chapter 11 Solutions
EBK THERMODYNAMICS: AN ENGINEERING APPR
Ch. 11.10 - Why is the reversed Carnot cycle executed within...Ch. 11.10 - Why do we study the reversed Carnot cycle even...Ch. 11.10 - 11–3 A steady-flow Carnot refrigeration cycle uses...Ch. 11.10 - Does the ideal vapor-compression refrigeration...Ch. 11.10 - Why is the throttling valve not replaced by an...Ch. 11.10 - It is proposed to use water instead of...Ch. 11.10 - In a refrigeration system, would you recommend...Ch. 11.10 - Does the area enclosed by the cycle on a T-s...Ch. 11.10 - Consider two vapor-compression refrigeration...Ch. 11.10 - The COP of vapor-compression refrigeration cycles...
Ch. 11.10 - An ice-making machine operates on the ideal...Ch. 11.10 - A 10-kW cooling load is to be served by operating...Ch. 11.10 - 11–13 An ideal vapor-compression refrigeration...Ch. 11.10 - 11–14 Consider a 300 kJ/min refrigeration system...Ch. 11.10 - 11–16 Repeat Prob. 11–14 assuming an isentropic...Ch. 11.10 - 11–17 Refrigerant-134a enters the compressor of a...Ch. 11.10 - A commercial refrigerator with refrigerant-134a as...Ch. 11.10 - 11–19 Refrigcrant-134a enters the compressor of a...Ch. 11.10 - A refrigerator uses refrigerant-134a as the...Ch. 11.10 - The manufacturer of an air conditioner claims a...Ch. 11.10 - Prob. 23PCh. 11.10 - How is the second-law efficiency of a refrigerator...Ch. 11.10 - Prob. 25PCh. 11.10 - Prob. 26PCh. 11.10 - Prob. 27PCh. 11.10 - 11–28 Bananas are to be cooled from 28°C to 12°C...Ch. 11.10 - A vapor-compression refrigeration system absorbs...Ch. 11.10 - A refrigerator operating on the vapor-compression...Ch. 11.10 - A room is kept at 5C by a vapor-compression...Ch. 11.10 - Prob. 32PCh. 11.10 - 11–33 A refrigeration system operates on the ideal...Ch. 11.10 - When selecting a refrigerant for a certain...Ch. 11.10 - Consider a refrigeration system using...Ch. 11.10 - A refrigerant-134a refrigerator is to maintain the...Ch. 11.10 - A refrigerator that operates on the ideal...Ch. 11.10 - A heat pump that operates on the ideal...Ch. 11.10 - Do you think a heat pump system will be more...Ch. 11.10 - What is a water-source heat pump? How does the COP...Ch. 11.10 - Prob. 42PCh. 11.10 - Refrigerant-134a enters the condenser of a...Ch. 11.10 - Prob. 45PCh. 11.10 - A heat pump using refrigerant-134a heats a house...Ch. 11.10 - How does the COP of a cascade refrigeration system...Ch. 11.10 - A certain application requires maintaining the...Ch. 11.10 - Consider a two-stage cascade refrigeration cycle...Ch. 11.10 - Can a vapor-compression refrigeration system with...Ch. 11.10 - Prob. 52PCh. 11.10 - Prob. 53PCh. 11.10 - Repeat Prob. 1156 for a flash chamber pressure of...Ch. 11.10 - Prob. 56PCh. 11.10 - Prob. 57PCh. 11.10 - 11–58 Consider a two-stage cascade refrigeration...Ch. 11.10 - Prob. 59PCh. 11.10 - A two-evaporator compression refrigeration system...Ch. 11.10 - A two-evaporator compression refrigeration system...Ch. 11.10 - Repeat Prob. 1163E if the 30 psia evaporator is to...Ch. 11.10 - How does the ideal gas refrigeration cycle differ...Ch. 11.10 - Devise a refrigeration cycle that works on the...Ch. 11.10 - How is the ideal gas refrigeration cycle modified...Ch. 11.10 - Prob. 66PCh. 11.10 - How do we achieve very low temperatures with gas...Ch. 11.10 - 11–68E Air enters the compressor of an ideal gas...Ch. 11.10 - Prob. 69PCh. 11.10 - Air enters the compressor of an ideal gas...Ch. 11.10 - Repeat Prob. 1173 for a compressor isentropic...Ch. 11.10 - Prob. 73PCh. 11.10 - Prob. 74PCh. 11.10 - Prob. 75PCh. 11.10 - A gas refrigeration system using air as the...Ch. 11.10 - An ideal gas refrigeration system with two stages...Ch. 11.10 - Prob. 78PCh. 11.10 - Prob. 79PCh. 11.10 - What are the advantages and disadvantages of...Ch. 11.10 - Prob. 81PCh. 11.10 - Prob. 82PCh. 11.10 - An absorption refrigeration system that receives...Ch. 11.10 - An absorption refrigeration system receives heat...Ch. 11.10 - Heat is supplied to an absorption refrigeration...Ch. 11.10 - Prob. 86PCh. 11.10 - Prob. 87PCh. 11.10 - Prob. 88PCh. 11.10 - Prob. 89PCh. 11.10 - Consider a circular copper wire formed by...Ch. 11.10 - An iron wire and a constantan wire are formed into...Ch. 11.10 - Prob. 92PCh. 11.10 - Prob. 93PCh. 11.10 - Prob. 94PCh. 11.10 - Prob. 95PCh. 11.10 - Prob. 96PCh. 11.10 - Prob. 97PCh. 11.10 - Prob. 98PCh. 11.10 - A thermoelectric cooler has a COP of 0.18, and the...Ch. 11.10 - Prob. 100PCh. 11.10 - Prob. 101PCh. 11.10 - Prob. 102PCh. 11.10 - Prob. 103RPCh. 11.10 - Prob. 104RPCh. 11.10 - Prob. 105RPCh. 11.10 - A heat pump that operates on the ideal...Ch. 11.10 - A large refrigeration plant is to be maintained at...Ch. 11.10 - Repeat Prob. 11112 assuming the compressor has an...Ch. 11.10 - A heat pump operates on the ideal...Ch. 11.10 - An air conditioner with refrigerant-134a as the...Ch. 11.10 - An air conditioner operates on the...Ch. 11.10 - Consider a two-stage compression refrigeration...Ch. 11.10 - A two-evaporator compression refrigeration system...Ch. 11.10 - Prob. 116RPCh. 11.10 - Prob. 117RPCh. 11.10 - Prob. 118RPCh. 11.10 - Consider a regenerative gas refrigeration cycle...Ch. 11.10 - Prob. 120RPCh. 11.10 - The refrigeration system of Fig. P11122 is another...Ch. 11.10 - Repeat Prob. 11122 if the heat exchanger provides...Ch. 11.10 - An ideal gas refrigeration system with three...Ch. 11.10 - Derive a relation for the COP of the two-stage...Ch. 11.10 - Prob. 129FEPCh. 11.10 - Prob. 130FEPCh. 11.10 - Prob. 131FEPCh. 11.10 - Prob. 132FEPCh. 11.10 - An ideal vapor-compression refrigeration cycle...Ch. 11.10 - Prob. 134FEPCh. 11.10 - An ideal gas refrigeration cycle using air as the...Ch. 11.10 - Prob. 136FEPCh. 11.10 - Prob. 137FEPCh. 11.10 - Prob. 138FEP
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Two methods used to power refrigeration compressors on a ship are _____and ____.arrow_forwardDefine net refrigeration effect as it applies to the refrigeration cycle.arrow_forwardA reversible refrigerator operates using a Carnot refrigeration cycle. It operates usingr-134a between 140 and 400 kPa. The refrigerant exits the compressor (and enters the condenser) assaturated vapor. It also leaves the condenser as saturated liquid.a. Sketch the P-v and T-s diagram of this cycle. Define the coordinate properties of each state oneach graph.b. Evaluate the specific heat and specific work properties of each (in kJ/kg). Indicate the sense.c. Evaluate the coefficient of performance using the specific heats and works from the previousitem. Did it match with the COPR obtained if you used the operating temperatures? Solve for states first. Then, show the solution to each of the above required in order.arrow_forward
- Q2: Two stage vapour compression refrigeration system with water intercooler uses R-22 as shown in figure 2 below. The evaporating temperature is -40 °C and condensing temperature 40 °C. The refrigeration capacity is 10 TR and the compression is adiabatic reversible process. The refrigerant leaves the water intercooler at 10 °C. Draw the cycle on p-h diagram and determine:- 1- The refrigerant mass flow rate. 2- Work done of each compressor. 3- Condenser heat load. >4- Coefficient of performance. 60 1arrow_forwardIn a R-134a based refrigeration system the cycle operates in the temperature range of 40°c and 20°c. Find COP of the system if the vapor is dry and saturated .while entering the compressor. Assume mass flow rate of refrigerant is 1 kg/s.arrow_forwardIn a R-134a based refrigeration system the cycle operates in the temperature range of 40°c and - 20°c. Find COP of the system if the vapor is dry and saturated .hile entering the compressor. Assume mass flow rate of refrigerant is 1 kg/s.arrow_forward
- Define COP of the simple vapor compression refrigeration cycle R-717. The evaporation temperature is -20°C and the condenser temperature is 40°C. COP=arrow_forwardIdea Vapor refrigeration Cycle uses R134 and operates between 70KPa and 900KPa. If the peak temperature coming out of the compressor is 40 degrees Celsius. What is the COP for this Cycle.arrow_forwardQ1: Refrigerant-134a is the working fluid in an ideal compression refrigeration cycle. The refrigerant leaves the evaporator -20°C and has a condenser pressure of 0.9 MPa. The mass flow rate is 3 kg/min. Find COPR, COPR, Carnot for same Tmax and Tmin , and the tons of refrigeration.arrow_forward
- determine the COP of the simple vapor compression refrigeration cycle R-134a. the evaporation temperature is -20 celsius and the condenser temperature is 30 celsius. COP =arrow_forwardA refrigerator operating using vapor-compression cycle uses R-134a as a working fluid. The condenser temperature is 65oC and the evaporator temperature is -15oC. The compressor operates at 80% efficiency. a. Determine the coefficient of performance of the refrigeration cycle. b. How much refrigerant is needed to deliver 3 kW of cooling? c. Sketch the vapor compression cycle indicating the states of each stream (in terms of H, P, T, and S) and showing the values of energy input/output in the system d. Suppose that we replace the expansion valve in the vapor- compression cycle with a turbine that operates at 80% efficiency. Determine the coefficient of performance of the refrigeration cycle. Provide the new state properties (i.e. H, P, T and S) for this changes Please use CATT for any values neededarrow_forwardA refrigeneration system with a capacity of 15 tons of refrigeration, operates at 150 kPa in the evaporator, while in the condenser it is 1380 kPa. If refrigerant R-717 is saturated, calculate the theoretical power required to operate the compressor. Compressor power= ... kWarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
![Text book image](https://www.bartleby.com/isbn_cover_images/9781305578296/9781305578296_smallCoverImage.gif)
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Power Plant Explained | Working Principles; Author: RealPars;https://www.youtube.com/watch?v=HGVDu1z5YQ8;License: Standard YouTube License, CC-BY