Chapter 12, Problem 31P
A balanced delta-connected load is supplied by a 60-Hz three-phase source with a line voltage of 480 V. Each load phase draws 24 kW at a lagging power factor of 0.8. Find:
- (a) the load impedance per phase
- (b) the line current
- (c) the value of capacitance needed to be connected in parallel with each load phase to minimize the current from the source
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
15 A of current is taken by a non-inductive load at 125 V. In order that the same current shall be generated from 240 V, 50 Hz mains. An inductor is now also then connected in series. Note: The resistance of the inductor should be ignored and also assume the waveform to be sinusoidal. Determine the phase difference between the current and the applied voltage, the impedance of the circuit and the inductance of the inductor.
low voltage systems
In the reverse phase, a 1000 kw powerful load under 0.5 power factor is fed from a 5 kv source.A capacitor is connected in parallel with the load to increase the power factor to 0.8.
a-) Find the required capacitor power.
b-) Compare the apparent power before and after compensation.
lši vl pir:10
Expert Q&A
+
1. For the circuit in Figure:
a. Determine I, VR, and Ve in phasor form.
b. Calculate the total power factor, and indicate whether it is leading or lagging.
c. Calculate the average power delivered to the circuit.
d. Draw the impedance diagram.
e. Find the voltages VR and Vcusing the voltage divider rule and compare them with the results of part(a) above.
+ Uc -
+ Ug -
30 2
L = 0.2 H
L =0.2 H
C = 4 µF
e = V2(20) sin(377t + 40°)
Expert Answer
Home
Search
More
II
Chapter 12 Solutions
EBK FUNDAMENTALS OF ELECTRIC CIRCUITS
Ch. 12.2 - Given that Vbn=22030V, find Van and Vcn, assuming...Ch. 12.3 - A Y-connected balanced three-phase generator with...Ch. 12.4 - One line voltage of a balanced Y-connected source...Ch. 12.5 - A positive-sequence, balanced -connected source...Ch. 12.6 - In a balanced -Y circuit, Vab=44015 and ZY = (12 +...Ch. 12.7 - For the Y-Y circuit in Practice Prob. 12.2,...Ch. 12.7 - Calculate the line current required for a 30-kW...Ch. 12.7 - Assume that the two balanced loads in Fig....Ch. 12.8 - The unbalanced -load of Fig. 12.24 is supplied by...Ch. 12.8 - Find the line currents in the unbalanced...
Ch. 12.9 - Prob. 11PPCh. 12.9 - For the unbalanced circuit in Fig. 12.32, use...Ch. 12.10 - Repeat Example 12.13 for the network in Fig. 12.24...Ch. 12.10 - Let the line voltage VL = 208 V and the wattmeter...Ch. 12.10 - If the load in Fig. 12.35 is delta-connected with...Ch. 12 - What is the phase sequence of a three-phase motor...Ch. 12 - If in an acb phase sequence, , then Vcn is:Ch. 12 - Which of these is not a required condition for a...Ch. 12 - Prob. 4RQCh. 12 - Prob. 5RQCh. 12 - In a Y-Y system, a line voltage of 220 V produces...Ch. 12 - In a - system, a phase voltage of 100 V produces a...Ch. 12 - When a Y-connected load is supplied by voltages in...Ch. 12 - Prob. 9RQCh. 12 - Prob. 10RQCh. 12 - If Vab = 400 V in a balanced Y-connected...Ch. 12 - What is the phase sequence of a balanced...Ch. 12 - Given a balanced Y-connected three-phase generator...Ch. 12 - A three-phase system with abc sequence and VL =...Ch. 12 - For a Y-connected load, the time-domain...Ch. 12 - Using Fig. 12.41, design a problem to help other...Ch. 12 - Obtain the line currents in the three-phase...Ch. 12 - In a balanced three-phase Y-Y system, the source...Ch. 12 - A balanced Y-Y four-wire system has phase voltages...Ch. 12 - For the circuit in Fig. 12.43, determine the...Ch. 12 - In the Y- system shown in Fig. 12.44, the source...Ch. 12 - Using Fig. 12.45, design a problem to help other...Ch. 12 - In the balanced three-phase Y- system in Fig....Ch. 12 - Obtain the line currents in the three-phase...Ch. 12 - The circuit in Fig. 12.48 is excited by a balanced...Ch. 12 - A balanced delta-connected load has a phase...Ch. 12 - A positive sequence wye-connected source where ,...Ch. 12 - If Van = 22060 V in the network of Fig. 12.49,...Ch. 12 - For the - circuit of Fig. 12.50, calculate the...Ch. 12 - Prob. 20PCh. 12 - Three 440-V generators form a delta-connected...Ch. 12 - Find the line currents IaA, IbB, and IcC in the...Ch. 12 - A balanced delta connected source is connected to...Ch. 12 - A balanced delta-connected source has phase...Ch. 12 - In the circuit of Fig. 12.54, if , , , find the...Ch. 12 - Using Fig. 12.55, design a problem to help other...Ch. 12 - A -connected source supplies power to a...Ch. 12 - The line-to-line voltages in a Y-load have a...Ch. 12 - A balanced three-phase Y- system has V rms and Z =...Ch. 12 - In Fig. 12.56, the rms value of the line voltage...Ch. 12 - A balanced delta-connected load is supplied by a...Ch. 12 - Design a problem to help other students better...Ch. 12 - A three-phase source delivers 4.8 kVA to a...Ch. 12 - A balanced wye-connected load with a phase...Ch. 12 - Three equal impedances, 60 + j30 each, are...Ch. 12 - A 4200-V, three-phase transmission line has an...Ch. 12 - The total power measured in a three-phase system...Ch. 12 - Given the circuit in Fig. 12.57 below, find the...Ch. 12 - Find the real power absorbed by the load in Fig....Ch. 12 - For the three-phase circuit in Fig. 12.59, find...Ch. 12 - A balanced delta-connected load draws 5 kW at a...Ch. 12 - A balanced three-phase generator delivers 7.2 kW...Ch. 12 - Refer to Fig. 12.48. Obtain the complex power...Ch. 12 - A three-phase line has an impedance of 1 + j3 per...Ch. 12 - A balanced wye-connected load is connected to the...Ch. 12 - A three-phase load consists of three 100-...Ch. 12 - The following three parallel-connected three-phase...Ch. 12 - A balanced, positive-sequence wye-connected source...Ch. 12 - Each phase load consists of a 20- resistor and a...Ch. 12 - A balanced three-phase source with VL = 240 V rms...Ch. 12 - Consider the wye-delta system shown in Fig. 12.60....Ch. 12 - A four-wire wye-wye circuit has...Ch. 12 - Using Fig. 12.61, design a problem that will help...Ch. 12 - A balanced three-phase Y-source with VP = 880 V...Ch. 12 - A three-phase supply, with the line-to-line...Ch. 12 - Using Fig. 12.63, design a problem to help other...Ch. 12 - Determine the line currents for the three-phase...Ch. 12 - Solve Prob. 12.10 using PSpice or MultiSim. For...Ch. 12 - The source in Fig. 12.65 is balanced and exhibits...Ch. 12 - Use PSpice or MultiSim to determine Io in the...Ch. 12 - Given the circuit in Fig. 12.67, use PSpice or...Ch. 12 - Using Fig. 12.68, design a problem to help other...Ch. 12 - Use PSpice or MultiSim to find currents IaA and...Ch. 12 - For the circuit in Fig. 12.58, use PSpice or...Ch. 12 - A balanced three-phase circuit is shown in Fig....Ch. 12 - A three-phase, four-wire system operating with a...Ch. 12 - As shown in Fig. 12.72, a three-phase four-wire...Ch. 12 - Meter readings for a three-phase wye-connected...Ch. 12 - A certain store contains three balanced...Ch. 12 - The two-wattmeter method gives P1=1200W and...Ch. 12 - In Fig. 12.73, two wattmeters are properly...Ch. 12 - If wattmeters W1 and W2 are properly connected...Ch. 12 - For the circuit displayed in Fig. 12.74, find the...Ch. 12 - Predict the wattmeter readings for the circuit in...Ch. 12 - Prob. 75PCh. 12 - Show that the I2R losses will be higher for a...Ch. 12 - A three-phase generator supplied 10 kVA at a power...Ch. 12 - Prob. 78CPCh. 12 - A balanced three-phase generator has an abc phase...Ch. 12 - A balanced three-phase source furnishes power to...Ch. 12 - A professional center is supplied by a balanced...Ch. 12 - A balanced three-phase system has a distribution...Ch. 12 - A commercially available three-phase inductive...Ch. 12 - Figure 12.76 displays a three-phase...Ch. 12 - Design a three-phase heater with suitable...Ch. 12 - For the single-phase three-wire system in Fig....Ch. 12 - Consider the single-phase three-wire system shown...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- The instantaneous power absorbed by the load in a single-phase ac circuit, for a general R LC load under sinusoidal-steady-state excitation. is (a) Nonzero constant (b) Zero (c) Containing double-frequency componentsarrow_forward)Two complex loads Z1 and Z2 are connected in parallel and powered by a value voltage effective 7.2 kV and frequency 60 Hz. The first load has a power of 50 kVA and a factor of rear power of 0.9. The second charge has a power of 45 kW and a rear power factorof 0.91. Determine in steady state the kVAR power and the capacity required to correct the Total power factor to a value of 0.97 rear.arrow_forwardThe values of the elements for the given circuit are given below.The maximum average power that can be transferred to the ZL load iswhich one?R1 = 400 OhmsL = 1000j OhmsR2 = 500 Ohmsarrow_forward
- An impedance load consisting of 12 ohms resistance and 16 ohms inductance reactance is connected across a 60 Hz, 100 V source. Find the capacitance of the condenser which may be paralleled with this load to bring the power factor to 0.80 lagging.arrow_forwardIn the circuit in the figure; L1 load draws 15 kVA with lagging power factor 0.6. The L2 load draws 6 kVA with a leading power factor of 0.8. According to this; What is the value of the complex power for the L2 load?arrow_forwardTwo impedances consist of resistance of (15 ohms and series connectedinductance of 0.04 henry) and (resistance of 10 ohms, inductance of 0.1 henryand a capacitance of 100 microfarad, all in series) are connected in series andare connected to 230 volts, 50 – Hz AC source. Find: (a) current drawn, (b) voltageacross each impedance, (c) individual and total power factor. Draw the phasordiagram.arrow_forward
- For the system in the figure: Find the total average power, total reactive power, total apparent power, and total power factor. Find the current Is (in phasor form). If the loads can be modeled as a resistance in series with a reactive element (capacitor or inductor), find the impedance of each load. Confirm the result of part B using the input voltage and the result of part C. ..arrow_forwardImpedances Z2 and Z3 in parallel are in series with impedance Z1 across a 100 V, 50 Hz ac supply. Z1 =6.25 + j1.25 ohm; Z2 = 5+ j0 ohm and Z3 = 5-jXc ohm. Determine the value of capacitance of Xc such that the total curent of the circuit will be in phase with the total voltage. When is then the circuit current and power.arrow_forwardThere are two loads connected in parallel and powered from a 7200-V source. The first load is 50-kVA at 0.9 power factor lagging, and the second load is 45-kW at 0.85 power factor lagging. Determine the kind of KVAR and capacitance required to correct the overall power factor to 0.96 lagging.arrow_forward
- Two impedances are connected in parallel to the supply, the first takes a current of 40 A at a lagging phase angle of 30°, and the second a current of 30 A at a leading phase angle of 45°. Draw a phasor diagram to scale to represent the supply voltage and these currents. From this diagram, by construction, determine the total current taken from the supply and its phase angle.arrow_forward8. The total power supplied to a balance delta load is found in the same way as for a balance wye load. True False Either Neither 12. A load of 20 + j35 ohms is connected across a 220 V, 60 Hz supply. Find the reactive power of the load in var. 595 2420 1042 1382 13. A type of DC source where the characteristic output voltage has perfect unidirectional waveform and is based on electrochemical principle. Generator Inverter Converter Battery 14. Calculate the Rf of a circuit whose impedance is 20+j35 and current of 2A. 0.86 0.91 0.50 0.71 15. What capacitor shall be installed in parallel with a circuit to achieve a unity power factor if the reactive power of a circuit is 200VARS and the voltage is 100V. 80.45 microfarad 53.05 microfarad It's already in unity 62.45 microfaradarrow_forwardExample: A balanced positive-sequence wye-connected 60 Hz three-phase source has line-to- line voltages of V,=1000 V. This source is connected to a balanced wye-connected load. Each phase of the load consists of a 0.2 H inductance in series with a 100 0 resistance. Find the line-to-neutral voltages, the line currents, the power, and the reactive power delivered to the load. Assume that the phase of Van is zero.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
What is the Difference Between Single Phase and Three Phase???; Author: Electrician U;https://www.youtube.com/watch?v=FEydcr4wJw0;License: Standard Youtube License