A balanced three-phase source furnishes power to the following three loads:
Load 1: 6 kVA at 0.83 pf lagging
Load 2: unknown
Load 3: 8 kW at 0.7071 pf leading
If the line current is 84.6 A rms, the line voltage at the load is 208 V rms, and the combined load has a 0.8 pf lagging, determine the unknown load.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A balanced three-phase source furnishes power to the following three loads:Load 1: 6 kVA at 0.83 power factor laggingLoad 2: unknownLoad 3: 8 kW at 0.7071 power factor leadingIf the line current is 84.6 A rms, the line voltage at the load is 208 V rms, and the combined loadhas a 0.8 power factor lagging, determine the unknown load.
A balanced three-phase source furnishes power to the following three loads: Load 1: 7 kVAat 0.83 pf lagging
Load 2: unknown
Load 3: 9 kVAat 0.7071 pf leading
If the line current is 76 Arms, the line voltage at the load is 211 Vrms, and the combined load has a 0.8 pf lagging, determine the unknown load.
A balanced three-phase source furnishes power to the following three loads:
Load 1: 8 kVA at 0.83 pf lagging
Load 2: unknown
Load 3: "12" kVA at 0.7071 pf leading If the line current is "73" Arms, the line voltage at the load is "221" Vrms, and the combined load has a 0.8 pf lagging, determine the unknown load.
Chapter 12 Solutions
Fundamentals of Electric Circuits
Ch. 12.2 - Given that Vbn=22030V, find Van and Vcn, assuming...Ch. 12.3 - A Y-connected balanced three-phase generator with...Ch. 12.4 - One line voltage of a balanced Y-connected source...Ch. 12.5 - A positive-sequence, balanced -connected source...Ch. 12.6 - In a balanced -Y circuit, Vab=44015 and ZY = (12 +...Ch. 12.7 - For the Y-Y circuit in Practice Prob. 12.2,...Ch. 12.7 - Calculate the line current required for a 30-kW...Ch. 12.7 - Assume that the two balanced loads in Fig....Ch. 12.8 - The unbalanced -load of Fig. 12.24 is supplied by...Ch. 12.8 - Find the line currents in the unbalanced...
Ch. 12.9 - Prob. 11PPCh. 12.9 - For the unbalanced circuit in Fig. 12.32, use...Ch. 12.10 - Repeat Example 12.13 for the network in Fig. 12.24...Ch. 12.10 - Let the line voltage VL = 208 V and the wattmeter...Ch. 12.10 - If the load in Fig. 12.35 is delta-connected with...Ch. 12 - What is the phase sequence of a three-phase motor...Ch. 12 - If in an acb phase sequence, , then Vcn is:Ch. 12 - Which of these is not a required condition for a...Ch. 12 - Prob. 4RQCh. 12 - Prob. 5RQCh. 12 - In a Y-Y system, a line voltage of 220 V produces...Ch. 12 - In a - system, a phase voltage of 100 V produces a...Ch. 12 - When a Y-connected load is supplied by voltages in...Ch. 12 - Prob. 9RQCh. 12 - Prob. 10RQCh. 12 - If Vab = 400 V in a balanced Y-connected...Ch. 12 - What is the phase sequence of a balanced...Ch. 12 - Given a balanced Y-connected three-phase generator...Ch. 12 - A three-phase system with abc sequence and VL =...Ch. 12 - For a Y-connected load, the time-domain...Ch. 12 - Using Fig. 12.41, design a problem to help other...Ch. 12 - Obtain the line currents in the three-phase...Ch. 12 - In a balanced three-phase Y-Y system, the source...Ch. 12 - A balanced Y-Y four-wire system has phase voltages...Ch. 12 - For the circuit in Fig. 12.43, determine the...Ch. 12 - In the Y- system shown in Fig. 12.44, the source...Ch. 12 - Using Fig. 12.45, design a problem to help other...Ch. 12 - In the balanced three-phase Y- system in Fig....Ch. 12 - Obtain the line currents in the three-phase...Ch. 12 - The circuit in Fig. 12.48 is excited by a balanced...Ch. 12 - A balanced delta-connected load has a phase...Ch. 12 - A positive sequence wye-connected source where ,...Ch. 12 - If Van = 22060 V in the network of Fig. 12.49,...Ch. 12 - For the - circuit of Fig. 12.50, calculate the...Ch. 12 - Prob. 20PCh. 12 - Three 440-V generators form a delta-connected...Ch. 12 - Find the line currents IaA, IbB, and IcC in the...Ch. 12 - A balanced delta connected source is connected to...Ch. 12 - A balanced delta-connected source has phase...Ch. 12 - In the circuit of Fig. 12.54, if , , , find the...Ch. 12 - Using Fig. 12.55, design a problem to help other...Ch. 12 - A -connected source supplies power to a...Ch. 12 - The line-to-line voltages in a Y-load have a...Ch. 12 - A balanced three-phase Y- system has V rms and Z =...Ch. 12 - In Fig. 12.56, the rms value of the line voltage...Ch. 12 - A balanced delta-connected load is supplied by a...Ch. 12 - Design a problem to help other students better...Ch. 12 - A three-phase source delivers 4.8 kVA to a...Ch. 12 - A balanced wye-connected load with a phase...Ch. 12 - Three equal impedances, 60 + j30 each, are...Ch. 12 - A 4200-V, three-phase transmission line has an...Ch. 12 - The total power measured in a three-phase system...Ch. 12 - Given the circuit in Fig. 12.57 below, find the...Ch. 12 - Find the real power absorbed by the load in Fig....Ch. 12 - For the three-phase circuit in Fig. 12.59, find...Ch. 12 - A balanced delta-connected load draws 5 kW at a...Ch. 12 - A balanced three-phase generator delivers 7.2 kW...Ch. 12 - Refer to Fig. 12.48. Obtain the complex power...Ch. 12 - A three-phase line has an impedance of 1 + j3 per...Ch. 12 - A balanced wye-connected load is connected to the...Ch. 12 - A three-phase load consists of three 100-...Ch. 12 - The following three parallel-connected three-phase...Ch. 12 - A balanced, positive-sequence wye-connected source...Ch. 12 - Each phase load consists of a 20- resistor and a...Ch. 12 - A balanced three-phase source with VL = 240 V rms...Ch. 12 - Consider the wye-delta system shown in Fig. 12.60....Ch. 12 - A four-wire wye-wye circuit has...Ch. 12 - Using Fig. 12.61, design a problem that will help...Ch. 12 - A balanced three-phase Y-source with VP = 880 V...Ch. 12 - A three-phase supply, with the line-to-line...Ch. 12 - Using Fig. 12.63, design a problem to help other...Ch. 12 - Determine the line currents for the three-phase...Ch. 12 - Solve Prob. 12.10 using PSpice or MultiSim. For...Ch. 12 - The source in Fig. 12.65 is balanced and exhibits...Ch. 12 - Use PSpice or MultiSim to determine Io in the...Ch. 12 - Given the circuit in Fig. 12.67, use PSpice or...Ch. 12 - Using Fig. 12.68, design a problem to help other...Ch. 12 - Use PSpice or MultiSim to find currents IaA and...Ch. 12 - For the circuit in Fig. 12.58, use PSpice or...Ch. 12 - A balanced three-phase circuit is shown in Fig....Ch. 12 - A three-phase, four-wire system operating with a...Ch. 12 - As shown in Fig. 12.72, a three-phase four-wire...Ch. 12 - Meter readings for a three-phase wye-connected...Ch. 12 - A certain store contains three balanced...Ch. 12 - The two-wattmeter method gives P1=1200W and...Ch. 12 - In Fig. 12.73, two wattmeters are properly...Ch. 12 - If wattmeters W1 and W2 are properly connected...Ch. 12 - For the circuit displayed in Fig. 12.74, find the...Ch. 12 - Predict the wattmeter readings for the circuit in...Ch. 12 - Prob. 75PCh. 12 - Show that the I2R losses will be higher for a...Ch. 12 - A three-phase generator supplied 10 kVA at a power...Ch. 12 - Prob. 78CPCh. 12 - A balanced three-phase generator has an abc phase...Ch. 12 - A balanced three-phase source furnishes power to...Ch. 12 - A professional center is supplied by a balanced...Ch. 12 - A balanced three-phase system has a distribution...Ch. 12 - A commercially available three-phase inductive...Ch. 12 - Figure 12.76 displays a three-phase...Ch. 12 - Design a three-phase heater with suitable...Ch. 12 - For the single-phase three-wire system in Fig....Ch. 12 - Consider the single-phase three-wire system shown...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A three-phase line with an impedance of (0.2+j1.0)/ phase feeds three balanced three-phase loads connected in parallel. Load 1: Absorbs a total of 150 kW and 120 kvar. Load 2: Delta connected with an impedance of (150j48)/phase. Load 3: 120 kVA at 0.6 PF leading. If the line-to-neutral voltage at the load end of the line is 2000 v (rms), determine the magnitude of the line-to-line voltage at the source end of the line.arrow_forwardConsider a three-phase Y-connected source feeding a balanced- load. The phasor sum of the line currents as well as the neutral current are always zero. (a) True (b) Falsearrow_forwardA balanced three-phase 240-V source supplies a balanced three-phase Load. If the line current IA is measured to be 15 A and is in phase with the line-to-line voltage, VBC, find the per-phase load impedance if the load is (a) Y-connected, (b) -conneeted.arrow_forward
- Two balanced Y-connected loads, one drawing 10 kW at 0.8 power factor lagging and the other IS kW at 0.9 power factor leading, are connected in parallel and supplied by a balanced three-phase Y-connected, 480-V source. (a) Determine the source current. (b) If the load neutrals are connected to the source neutral by a zero-ohm neutral wire through an ammeter, what will the ammeter read?arrow_forwardA balanced three-phase source furnishes power to the following three loads:Load 1: 6 kVA at 0.83 pf laggingLoad 2: unknownLoad 3: 8 kW at 0.7071 pf leadingIf the line current is 84.6 A rms, the line voltage at the load is 208 V rms, and the combined load has a0.8 pf lagging, determine the unknown load.arrow_forwardA balanced three-phase distribution line has an impedance of 1+j8 Ω/ϕ. This line is used to supply three balanced three-phase loads that are connected in parallel. The three loads are L1=120 kVA at 0.96 pf leading, L2=180 kVA at 0.80 pf lagging, and L3=100.8 kW and 15.6 kVAR (magnetizing). The magnitude of the line voltage at the terminals of the loads is 24003 V. 1. a) What is the magnitude of the line voltage at the sending end of the line? 2. b) What is the percent efficiency of the distribution line with respect to average power?arrow_forward
- Determine the line current of a Y-connected balanced three-phase load, consuming 300 kW at power factor = 0.8 lagging and operating at 480 V. Work on PER UNIT with Sbase = 375 kVA and Vbase = 480V. Choose the best answer.arrow_forwardA balanced three-phase source is supplying 60 kVA at 0.6 lagging to two balanced Y-connected parallel loads. The distribution line connecting the source to the load has negligible impedance. Load 1 is purely resistive and absorbs 30 kW. Find the per-phase impedance of Load 2 if the line voltage is 1203 V and the impedance components are in series.arrow_forwardA balanced three-phase distribution line has an impedance of (1 +j8)ohm/phase .This line is used to supply three balanced three-phase loads that are connected in parallel. The three loads are:Load I: S1/phase = 40kVA at a power factor of 0.96 leading.Load 2: S2/phase = 60 kVA at a power factor of 0.8 lagging.Load 3: P3/phase= 33.6 kW and Q3/phase = 5.2 kVAR.The magnitude of the phase-to-neutral voltage at the terminals of the loads is2400 V (rms)and is considered as phase reference. A)find the complex apparent power per phase at the source end of the linearrow_forward
- A balanced three-phase distribution line has an impedance of (1 +j8)ohm/phase .This line is used to supply three balanced three-phase loads that are connected in parallel. The three loads are:Load I: S1/phase = 40kVA at a power factor of 0.96 leading.Load 2: S2/phase = 60 kVA at a power factor of 0.8 lagging.Load 3: P3/phase= 33.6 kW and Q3/phase = 5.2 kVAR.The magnitude of the phase-to-neutral voltage at the terminals of the loads is2400 V (rms)and is considered as phase reference.a) Find the total complex apparent power per phase STotal/phaseb)Draw the single phase equivalent circuit.c)What is the magnitude of the phase-to-neutral voltage at the sending end of the line?d)Find the complex apparent power per phase at the source end ofthe line.arrow_forwardDetermine the amplitude of the line current in a three-phase system with a line voltage of 207 V that supplies 828 W to Δ-connected load at a lagging PF of 0.55, then find the phase impedance.arrow_forwardA balanced three-phase source is supplying 60 kVA at 0.96 pf leading to two balanced Δ-connected parallel loads. The distribution line connecting the source to the load has negligible impedance. Load 1 is purely resistive and absorbs 45 kW. 1. a) Determine the types of components and their impedances in each phase of load 2 if the line voltage is 630 V and the impedance components are in series. 2. b) Repeat (a) with the impedance components in parallel.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
What is the Difference Between Single Phase and Three Phase???; Author: Electrician U;https://www.youtube.com/watch?v=FEydcr4wJw0;License: Standard Youtube License