A balanced Y-Y four-wire system has phase voltages
The load impedance per phase is 19 + j13 Ω, and the line impedance per phase is 1 + j2 Ω. Solve for the line currents and neutral current.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A balanced, positive-sequence, Y-connected voltage source with Eab = 480∠0o volts is applied to abalanced-∆ load with Z∆ = 30 ∠40o Ω. The line impedance between the source and load is ZL = 1 ∠850 Ω.for each phase. Calculate the line currents, the ∆ -load currents, and the voltages at the load terminals.Recall that ZY = Z∆/3
30. A 30-Y-connected load is connected between three line terminals, R, Y, B, the impedances (in ohms) of the load being: (I + 2) between R and the star point. (2+3) between Y and the star point and (3+j4) between B and the star point. The phase sequence is RYB. If the line voltage is 400 V, calculate the voltage between R and the star point. [181 V]
A balanced Y-connected load is connected to 3-phase transmission lines with line-to-line voltages of 21.5 kV. The current in each line is 75 A. What are the phase impedances of the Y-connected load?
Chapter 12 Solutions
FUNDAMENTALS OF ELEC.CIRC.(LL)-W/ACCESS
Ch. 12.2 - Given that Vbn=22030V, find Van and Vcn, assuming...Ch. 12.3 - A Y-connected balanced three-phase generator with...Ch. 12.4 - One line voltage of a balanced Y-connected source...Ch. 12.5 - A positive-sequence, balanced -connected source...Ch. 12.6 - In a balanced -Y circuit, Vab=44015 and ZY = (12 +...Ch. 12.7 - For the Y-Y circuit in Practice Prob. 12.2,...Ch. 12.7 - Calculate the line current required for a 30-kW...Ch. 12.7 - Assume that the two balanced loads in Fig....Ch. 12.8 - The unbalanced -load of Fig. 12.24 is supplied by...Ch. 12.8 - Find the line currents in the unbalanced...
Ch. 12.9 - Prob. 11PPCh. 12.9 - For the unbalanced circuit in Fig. 12.32, use...Ch. 12.10 - Repeat Example 12.13 for the network in Fig. 12.24...Ch. 12.10 - Let the line voltage VL = 208 V and the wattmeter...Ch. 12.10 - If the load in Fig. 12.35 is delta-connected with...Ch. 12 - What is the phase sequence of a three-phase motor...Ch. 12 - If in an acb phase sequence, , then Vcn is:Ch. 12 - Which of these is not a required condition for a...Ch. 12 - Prob. 4RQCh. 12 - Prob. 5RQCh. 12 - In a Y-Y system, a line voltage of 220 V produces...Ch. 12 - In a - system, a phase voltage of 100 V produces a...Ch. 12 - When a Y-connected load is supplied by voltages in...Ch. 12 - Prob. 9RQCh. 12 - Prob. 10RQCh. 12 - If Vab = 400 V in a balanced Y-connected...Ch. 12 - What is the phase sequence of a balanced...Ch. 12 - Given a balanced Y-connected three-phase generator...Ch. 12 - A three-phase system with abc sequence and VL =...Ch. 12 - For a Y-connected load, the time-domain...Ch. 12 - Using Fig. 12.41, design a problem to help other...Ch. 12 - Obtain the line currents in the three-phase...Ch. 12 - In a balanced three-phase Y-Y system, the source...Ch. 12 - A balanced Y-Y four-wire system has phase voltages...Ch. 12 - For the circuit in Fig. 12.43, determine the...Ch. 12 - In the Y- system shown in Fig. 12.44, the source...Ch. 12 - Using Fig. 12.45, design a problem to help other...Ch. 12 - In the balanced three-phase Y- system in Fig....Ch. 12 - Obtain the line currents in the three-phase...Ch. 12 - The circuit in Fig. 12.48 is excited by a balanced...Ch. 12 - A balanced delta-connected load has a phase...Ch. 12 - A positive sequence wye-connected source where ,...Ch. 12 - If Van = 22060 V in the network of Fig. 12.49,...Ch. 12 - For the - circuit of Fig. 12.50, calculate the...Ch. 12 - Prob. 20PCh. 12 - Three 440-V generators form a delta-connected...Ch. 12 - Find the line currents IaA, IbB, and IcC in the...Ch. 12 - A balanced delta connected source is connected to...Ch. 12 - A balanced delta-connected source has phase...Ch. 12 - In the circuit of Fig. 12.54, if , , , find the...Ch. 12 - Using Fig. 12.55, design a problem to help other...Ch. 12 - A -connected source supplies power to a...Ch. 12 - The line-to-line voltages in a Y-load have a...Ch. 12 - A balanced three-phase Y- system has V rms and Z =...Ch. 12 - In Fig. 12.56, the rms value of the line voltage...Ch. 12 - A balanced delta-connected load is supplied by a...Ch. 12 - Design a problem to help other students better...Ch. 12 - A three-phase source delivers 4.8 kVA to a...Ch. 12 - A balanced wye-connected load with a phase...Ch. 12 - Three equal impedances, 60 + j30 each, are...Ch. 12 - A 4200-V, three-phase transmission line has an...Ch. 12 - The total power measured in a three-phase system...Ch. 12 - Given the circuit in Fig. 12.57 below, find the...Ch. 12 - Find the real power absorbed by the load in Fig....Ch. 12 - For the three-phase circuit in Fig. 12.59, find...Ch. 12 - A balanced delta-connected load draws 5 kW at a...Ch. 12 - A balanced three-phase generator delivers 7.2 kW...Ch. 12 - Refer to Fig. 12.48. Obtain the complex power...Ch. 12 - A three-phase line has an impedance of 1 + j3 per...Ch. 12 - A balanced wye-connected load is connected to the...Ch. 12 - A three-phase load consists of three 100-...Ch. 12 - The following three parallel-connected three-phase...Ch. 12 - A balanced, positive-sequence wye-connected source...Ch. 12 - Each phase load consists of a 20- resistor and a...Ch. 12 - A balanced three-phase source with VL = 240 V rms...Ch. 12 - Consider the wye-delta system shown in Fig. 12.60....Ch. 12 - A four-wire wye-wye circuit has...Ch. 12 - Using Fig. 12.61, design a problem that will help...Ch. 12 - A balanced three-phase Y-source with VP = 880 V...Ch. 12 - A three-phase supply, with the line-to-line...Ch. 12 - Using Fig. 12.63, design a problem to help other...Ch. 12 - Determine the line currents for the three-phase...Ch. 12 - Solve Prob. 12.10 using PSpice or MultiSim. For...Ch. 12 - The source in Fig. 12.65 is balanced and exhibits...Ch. 12 - Use PSpice or MultiSim to determine Io in the...Ch. 12 - Given the circuit in Fig. 12.67, use PSpice or...Ch. 12 - Using Fig. 12.68, design a problem to help other...Ch. 12 - Use PSpice or MultiSim to find currents IaA and...Ch. 12 - For the circuit in Fig. 12.58, use PSpice or...Ch. 12 - A balanced three-phase circuit is shown in Fig....Ch. 12 - A three-phase, four-wire system operating with a...Ch. 12 - As shown in Fig. 12.72, a three-phase four-wire...Ch. 12 - Meter readings for a three-phase wye-connected...Ch. 12 - A certain store contains three balanced...Ch. 12 - The two-wattmeter method gives P1=1200W and...Ch. 12 - In Fig. 12.73, two wattmeters are properly...Ch. 12 - If wattmeters W1 and W2 are properly connected...Ch. 12 - For the circuit displayed in Fig. 12.74, find the...Ch. 12 - Predict the wattmeter readings for the circuit in...Ch. 12 - Prob. 75PCh. 12 - Show that the I2R losses will be higher for a...Ch. 12 - A three-phase generator supplied 10 kVA at a power...Ch. 12 - Prob. 78CPCh. 12 - A balanced three-phase generator has an abc phase...Ch. 12 - A balanced three-phase source furnishes power to...Ch. 12 - A professional center is supplied by a balanced...Ch. 12 - A balanced three-phase system has a distribution...Ch. 12 - A commercially available three-phase inductive...Ch. 12 - Figure 12.76 displays a three-phase...Ch. 12 - Design a three-phase heater with suitable...Ch. 12 - For the single-phase three-wire system in Fig....Ch. 12 - Consider the single-phase three-wire system shown...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A balanced three-phase 240-V source supplies a balanced three-phase Load. If the line current IA is measured to be 15 A and is in phase with the line-to-line voltage, VBC, find the per-phase load impedance if the load is (a) Y-connected, (b) -conneeted.arrow_forwardIt is stated that (i) balanced three-phase circuits can be solved in per unit on a per-phase basis after converting - load impedances to equivalent Y impedances. (ii) Base values can be selected either on a per-phase basis or on a three-phase basis. (a) Both statements are true. (b) Neither is true. (c) Only one of the above is true.arrow_forwardA three-phase line with an impedance of (0.2+j1.0)/ phase feeds three balanced three-phase loads connected in parallel. Load 1: Absorbs a total of 150 kW and 120 kvar. Load 2: Delta connected with an impedance of (150j48)/phase. Load 3: 120 kVA at 0.6 PF leading. If the line-to-neutral voltage at the load end of the line is 2000 v (rms), determine the magnitude of the line-to-line voltage at the source end of the line.arrow_forward
- Two balanced three-phase loads that are connected in parallel are fed by a three-phase line having a series impedance of (0.4j2.7) per phase. One of the loads absorbs 560 kVA at 0.707 power factor lagging, and the other 132 kW at unity power factor. The line-to-line voltage at the load end of the line is 2203V. Compute (a) the line-to-line voltage at the source end of the line. (b) the total real and reactive power losses in the three-phase line, and (c) the total three-phase real and reactive power supplied at the sending end of the line. Check that the total three-phase complex power delivered by the source equals the total three-phase comp lex power absorbed by the line and loads.arrow_forwardA balanced Y-Y four-wire system has phase voltages ??? = 120∠0° V, ??? = 120∠ − 120° V, ??? = 120∠120° V The load impedance per phase is 19 + ?13 Ω and the line impedance per phase is 1 + ?2 Ω, Solve for the line currents and neutral currentarrow_forwardA 3 phase 13-KV transmission line delivers 8 MVA of load. The per phase impedance of the line is (0.01 + j 0.05 ) p.u. referred to a 13 – KV, 8 – MVA base. What is the voltage drop across the line?arrow_forward
- single circuit three-phase line, 60 Hz, 18 km has a total resistance and inductive reactance of 4.242 ohm and7.451 ohm per phase respectively. The line delivers 2500 kW to a balanced load at 11 kV. (1) determine the sending-end voltage when the power factor is (i) 80% lagging, (i) unity, and (ii) 90 % leading, (2) draw the phasor diagrams of the line at the above (3) determine the voltage regulation of the line at the above power factors.arrow_forward1. A 69-kV, three-phase short transmission line is 16 km long. The line has a per phase series impedance of 0.125+j0.4375 Ω per km. Determine the sending end voltage, voltage regulation, the sending end power, and the transmission efficiency when the line delivers (a) 70 MVA, 0.8 lagging power factor at 64 kV. (b) 120 MW, unity power factor at 64 kV. Use lineperf program to verify your results. 2. A three-phase, 765-kV, 60-Hz transposed line is composed of four ACSR, l,431,000-cmil, 45/7 Bobolink conductors per phase with flat horizontal spacing of 14 m. The conductors have a diameter of 3.625 cm and a GMR of 1.439 cm. The bundle spacing is 45 cm. The line is 400 km long, and for the purpose of this problem, a lossless line is assumed. (a) Determine the transmission line surge impedance Zc, phase constant ß, Wavelength, the surge impedance loading SIL, and the ABCD constant. b) The line delivers 2000 MVA at 0.8 lagging power factor at 735 kV. Determine the sending end quantities and…arrow_forwardA Y-Y three-phase system has a source of 380 V and a load of impedance of 6+j5 Ohm/phase through a transmission line of 2+j 1 Ohm/phase.Plot this Y-Y three-phase system then calculate complex power supplied by the source.arrow_forward
- A three-phase 6OO-V circuit has two balanced loads connected in parallel, one Δ impedance 9?∠40 ° Ω and the other Y impedance 5? ∠30 ° Ω. Find the total current of the effective line and the total average power absorbed.arrow_forwardl. A single-phase distributor AB has a total impedance 0f (0.1+j0.2) ohms. At the far end B, a current of 80A at 0.8 pf lagging and at mid-point C a current of 100A at 0.6 pf lagging are tapped. If the voltage at B is maintained at 200V, determine the sending end voltage.arrow_forwardA balanced delta-connected load has phase impedances of 4+j3 Ohms. It is connected to balanced transmission lines, with Vab = 1.5kV @ 15 degrees. a) What is the current through each of the load phases? b) What is the current through each of the transmission lines? c) Which ACSR cable should be used for these transmission lines to give a 20% current rating margin for this load?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
What is the Difference Between Single Phase and Three Phase???; Author: Electrician U;https://www.youtube.com/watch?v=FEydcr4wJw0;License: Standard Youtube License