Assume that the two balanced loads in Fig. 12.22(a) are supplied by an 840-V rms 60-Hz line. Load 1 is Y-connected with 30 + j40 Ω per phase, while load 2 is a balanced three-phase motor drawing 48 kW at a power factor of 0.8 lagging. Assuming the abc sequence, calculate: (a) the complex power absorbed by the combined load, (b) the kVAR rating of each of the three capacitors Δ-connected in parallel with the load to raise the power factor to unity, and (c) the current drawn from the supply at unity power factor condition.
Want to see the full answer?
Check out a sample textbook solutionChapter 12 Solutions
FUNDAMENTALS OF ELECTRIC...(LL)>CUSTOM<
Additional Engineering Textbook Solutions
Engineering Electromagnetics
Electric machinery fundamentals
Principles and Applications of Electrical Engineering
Basic Engineering Circuit Analysis
Principles Of Electric Circuits
Loose Leaf for Engineering Circuit Analysis Format: Loose-leaf
- A short 3-phase transmission line connected to a 33kV, 50 Hz generating station at the sending end is required to supply a load of 10 MW at 0·8 lagging power factor at 30 kV at the receiving end. If the minimum transmission efficiency is to be limited to 96%, estimate the per phase value of resistance and inductance of the line. [2·4 Ω; 0·028 H]arrow_forwardAssume that the two balanced loads in Fig. are supplied by an 840-V rms 60-Hz line. Load I is Y-connected with 30+ j40 S2 per phase, while load 2 is a balanced three-phase motor drawing 48 kW at a power factor of 0.8 lagging. Assuming the abc sequence, calculate: (a) the complex power absorbed by the combined load, (b) the kVAR rating of each of the three capacitors A-connected in parallel with the load to raise the power factor to unity, and (c) the current drawn from the supply at unity power factor condition.arrow_forward2. A 12500 kVA load is supplied at a power factor of 0·8 lagging by a 3-phase transmission line whosevoltage is to be maintained at 33 kV at both ends. Determine the capacity of the synchronous condenserto be installed at the receiving end. The impedance of the line is (4 + j 12) ohms per phase. solution is [11490 kVAR]arrow_forward
- Exercise 1: A three-phase 3Φ transmission line has an impedance of 0.62+j35.06Ω/phase and supplies a three-phase load of 100MW with a power factor (fp) of 0.8 lagging at 200kV. Taking 100MVA and 215kV as a base, we ask: d-) Calculate the complex power consumed by the load in p.u;e-) Calculate the voltage at the emitter terminal in p.u;f-) Calculate the LT impedance taking 200MVA and 150kV as a new base. PLEASE, TYPE, HAND WRITING GETS UNDERSTANDING.arrow_forwardA single – phase transmission line supplies a reactive load at a lagging power factor. The load draws 1.2 pu current at 0.6 pu voltage while drawing 0.5 pu (true) power. If the base voltage is 20 kV and the base current is 160 A, calculate the power factor and the ohmic value of the resistance of the load.arrow_forwardEach leg of a symmetric, Y‐connected, 3Φ load has an impedance of 10∠36.87° Ω, and is connected to the 3Φ source from Problem 1 via an ideal transmission line (that is, the connection from the source to the load has zero impedance). a. Determine the line currents. That is, find Ia, Ib, and Ic. b. Determine the complex power consumed by each leg of the load. c. Determine the total complex power consumed by the entire 3Φ load. d. caclculate instantaneous power p(t) consumed by the load problem 1 : A 60 Hz, balanced, positive‐sequence, Y‐connected, 3Φ voltage source has Van = 120∠0° Vrmsarrow_forward
- A 50 Hz, 250 V single phase power line has the following loads placed across it in paralell; 4 kW at a pf of 0. 8 lagging; 6 kVA at a pf of 0.6 lagging; 5 kVA which includes 1.2 kVAR leading. Determine the overall pf of the system and the capacitance of the capacitor which, if connected across the mains restore the power factor to unity.arrow_forwardA three-phase line with an impedance of (0.2+j1.0)/ phase feeds three balanced three-phase loads connected in parallel. Load 1: Absorbs a total of 150 kW and 120 kvar. Load 2: Delta connected with an impedance of (150j48)/phase. Load 3: 120 kVA at 0.6 PF leading. If the line-to-neutral voltage at the load end of the line is 2000 v (rms), determine the magnitude of the line-to-line voltage at the source end of the line.arrow_forwardA balanced load consists of three coils with each coil having a resistance of 10Ω and an induction reactance of 15Ω The load is conneted as star to a 420 V, three-phase, 50 Hz supply as shown in the Fig.. For abc phase sequence, find (i) the line currents, and (ii) power factor.arrow_forward
- An Alternator having three-phase, 3-wire ABC system supplying an effective line voltage of 120 V, has an a three-impedances of 50 / 45 ohms in Delta connection. Assume that Vbc is the reference vector. In problem above, assuming that it is Wye connected load and VAN is the reference vector. Determine the total true power, reactive power, apparent power of the connected load. What is the capacity in Kva of synchronous generator if the connected load is 85%arrow_forwardA 12470 Vrms, 3-phase 60 Hz supply is applied to a balanced Delta-connected 3-phase load consisting of 3 identical impedances of Z=48∠ 36.87°Ω Calculate (a) The current in each line.arrow_forwardThe length of a three-phase power transmission line with a nominal operating voltage of 69 kV is 16km. The impedance of the transmission line per unit length is 0.125 + j0.4375 ohm/ km. At the end of the line, a 70 MVA star connected load with a power factor of 0.8 back under 69 kV interphase voltage is fed. Capacitive circuit element with a capacitance of 19.14 mikro F / phase is placed as shunt at the end of the transmission line. According to these given; a) Line head voltage and current, b) Calculate the active and reactive power per line.arrow_forward
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning