Question
Chapter 13, Problem 13.18QAP
Interpretation Introduction
Interpretation:
The reason for using the iodine inside the tungsten lamp should be determined.
Concept introduction:
The tungsten lamp is same as the other halogen lamp and these lamps have a life time double of that of the ordinary bulbs. The increased life time of the tungsten lamp is due to the presence of the iodine inside the lamp.
Expert Solution & Answer
![Check Mark](/static/check-mark.png)
Trending nowThis is a popular solution!
![Blurred answer](/static/blurred-answer.jpg)
Students have asked these similar questions
Why are metals resposbile for the production of colour upon heating
UV-Vis spectrophotometry is used to determine copper. Aside from UV-Vis spectrophotometry what other techniques can be used to determine copper. Explain the process and how it is done
How does fluorescence work in bulk semiconductors?
Chapter 13 Solutions
Principles of Instrumental Analysis, 6th Edition
Ch. 13 - Prob. 13.1QAPCh. 13 - Prob. 13.2QAPCh. 13 - Prob. 13.3QAPCh. 13 - Prob. 13.4QAPCh. 13 - Prob. 13.5QAPCh. 13 - Prob. 13.6QAPCh. 13 - Prob. 13.7QAPCh. 13 - At 580 nm, which is the wavelength of its maximum...Ch. 13 - Prob. 13.9QAPCh. 13 - Zinc(II) and the ligand L form a 1:1 complex that...
Ch. 13 - The equilibrium constant for the conjugate...Ch. 13 - The equilibrium constant for the reaction...Ch. 13 - Prob. 13.13QAPCh. 13 - Prob. 13.14QAPCh. 13 - Prob. 13.15QAPCh. 13 - Prob. 13.16QAPCh. 13 - Prob. 13.17QAPCh. 13 - Prob. 13.18QAPCh. 13 - Prob. 13.19QAPCh. 13 - Prob. 13.20QAPCh. 13 - Prob. 13.21QAPCh. 13 - Prob. 13.22QAPCh. 13 - Prob. 13.23QAPCh. 13 - Prob. 13.24QAPCh. 13 - Prob. 13.25QAPCh. 13 - Prob. 13.26QAPCh. 13 - Prob. 13.27QAP
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- This shows the spectrum of visible light. From what you have learned about excitation and emission of 'flurophores' used in fluorescence microscopy, answer this question: A fluorophore that is 'excited' by light with a wavelength of 570 nanometers (nm), would, by necessity, 'emit' light somewhere in this range ___. (There are two choices.) Light, the visible spectrum violet Indigo 675 r frequency 750 (THE) wavelength 400 photon 3.1 energy (1) Encyclopedia Britannica, Inc. 445 2.8 1 blue T 630 475 1 2.6 1 groen 500 510 24 1 yellow orange 525 510 570 590 1 2.2 21 400nm-569nm Q571nm-780nm red 460 650 1.9 380 780 1.6 in terahertz (THz: 1 THz - 1x102 cycles per second. in nanometres (nm); 1nm 1x10 metre. in electron volts (V)arrow_forwardIf you are measuring manganese (Mn) absorption using AAS, which hollow cathode lamp would you select as your source and why?arrow_forwardWhat is affinity elutionarrow_forward
- What are the advantages and disadvantages of using quantum dots for fluorescence imaging?arrow_forward3. Which property is measured in the following techniques? a) Potentiometry b) Amperometry c) Conductometry d) Electrogravimetry e) Voltammetryarrow_forwardList and describe all advantages of XRF and NAA techniquesarrow_forward
- When fusing with resorcinol and adding ammonia to the alloy, a solution with green fluorescence forms: A) Gamma-aminobutyric acid B) Piracetam C) Potassium acetate D) Glutamic acidarrow_forwardA standard iron solution was prepared by dissolving 0.0140 g of pure iron in acid then transferring to a 50.00 mL volumetric flask with orthophenanthroline as a complexing agent. At a wavelength of 540 nm, the absorbance of the standard was 0.214 in a 1.00 cm cuvette. A 0.128 g sample of an iron ore was crushed and digested in 5 mL of concentrated acid. The digested sample was then transferred to a 10.00 mL volumetric flask and diluted to the mark with water. A 1.00 mL aliquot of the sample was transferred to a 25.00 mL volumetric flask, and diluted to the mark with water. A portion of the diluted sample was then transferred to a 1.00 cm cuvette and measured at a wavelength of 540 nm. The resulting absorbance was 0.216. Determine the % w/w of Fe in the iron ore.arrow_forwardWhat is the significance of whether the fluorescent substance in fluorescent tubes has a short or long phosphorescence?arrow_forward
- TRUE OR FALSE Interstellar reddening results when stars near death become Red Giants.arrow_forwardIn optical analysis, what are the methods used to calculate the concentration ofa solution from the absorbance measurements of colorimeters?arrow_forwardWhy should absorbance be less than 2? Please explain in terms of light transmittancearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
- Principles of Modern ChemistryChemistryISBN:9781305079113Author:David W. Oxtoby, H. Pat Gillis, Laurie J. ButlerPublisher:Cengage Learning
![Text book image](https://www.bartleby.com/isbn_cover_images/9781305577213/9781305577213_smallCoverImage.gif)
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
![Text book image](https://www.bartleby.com/isbn_cover_images/9781337399692/9781337399692_smallCoverImage.gif)
![Text book image](https://www.bartleby.com/isbn_cover_images/9781305079113/9781305079113_smallCoverImage.gif)
Principles of Modern Chemistry
Chemistry
ISBN:9781305079113
Author:David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:Cengage Learning