EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN: 9781337516549
Author: Simmons
Publisher: CENGAGE LEARNING - CONSIGNMENT
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 17, Problem 13R
To determine
Find the article in NEC that defines the given statement.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
You are asked to replace an ungrounded receptacle (two wire) and there is not a source of ground available.
1. It is permissible to replace the receptacle with a GFCI receptacle?
2. If so, how must the receptacle plate be marked.
Be sure and cite code references.
QUESTION 25
Type TC cable shall not be _____.
a.
installed where it will be exposed to physical damage
b.
all of these
c.
installed outside of a race-way or cable tray system, unless permitted in 336.10(4), 336.10(7), 336.10(9), and 336.10(10)
d.
used where exposed to direct rays of the sun, unless identified as sunlight resistant
What is the NEC code for a receptacle by a pool
Chapter 17 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 17 - What is the total current draw when all six...Ch. 17 - The junction box that will be installed above the...Ch. 17 - Why is it important that the hot conductor in a...Ch. 17 - In the diagram, Load A is rated at 10 amperes, 120...Ch. 17 - Calculate the watts loss and voltage drop in each...Ch. 17 - Unless specifically designed, all recessed...Ch. 17 - Where in the NEC would you look for the...Ch. 17 - What is the current draw of the recessed...Ch. 17 - Prob. 9RCh. 17 - Calculate the total current draw for Circuit B9,...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- True or False: Receptacles used on the job site should be protected with a GFCI.arrow_forwardWhen installing GFCI and AFCI circuit breakers in a panelboard, it is permissible to connect them to a multiwire branch circuit. (True) (False). (Circle the correct answer.)arrow_forwardAssuming that an outlet box for the entry ceiling has a fixture stud but has external cable clamps, what size box could be installed? Show calculations for both metal and nonmetallic boxes. ___________arrow_forward
- A Type NM cable carries a branch circuit to the outside of a building, where it terminates in a metal weatherproof junction box. From this box, a short length of EMT is installed upward to another metal weatherproof junction box on which is attached a cluster of outdoor floodlights. The first box is located approximately 24 in. (600 mm) above the ground. To Meet Code, do the metal boxes and metal raceway have to be grounded? Yes _______________ No _______________ NEC _______________.arrow_forwardIs a GFCI receptacle permitted be installed as a replacement in an old installation where the 2-wire circuit has no equipment grounding conductor? _________________arrow_forward_______ type receptacles must be installed on all 15- and 20-ampere branch circuits except for replacement receptacles as permitted by 406.4(D). Select one: a. AFCI b. GFCI c. Duplex d. Groundingarrow_forward
- For installing directly in a concrete slab, (armored cable), (non metallic-sheated cable), (rigid metal conduit) may be used. (Circle the correct method of installation.)arrow_forwardPlans require the installation of surface-mounted fluorescent luminaires on the ceiling of a recreation room that is finished with low-density ceiling fiberboard. What sort of mark would you look for on the label of the luminaire? ________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________arrow_forwardThe receptacle outlets in the garage are required to have both GFCI and AFCI protection. (True) (False) (Circle the correct answer.)arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning