Textbook Question
Chapter 18, Problem 11R
Adjustment factors for conductor ampacities must always be taken into consideration when (a) _____________ are contained in one raceway.
Correction factors are applied when (b) ___________________
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
The frames of ranges, wall-mounted ovens, counter-mounted cooking units, and clothes dryers under the conditions permitted for existing installations, ___ permitted to be connected to the grounded circuit conductor.
Select one:
a. shall not be
b. can not
c. may be
d. shall be
Are double locknuts an acceptable bonding method for Class 1, Division 1 Hazardous locations?
If not, list an acceptable method, backing up your answer with a code citation.
10.a. Which of the following is a condition of the exception that allows the grounded conductor of feeders tobe used for grounding at separate buildings or structures?A. There are common electrically continuous metallic paths between the feeder source and the destination at the structure served.B. There are common electrically continuous nonmetallic paths between the equipment grounding conductor and the destinationat the structure served.C. An equipment grounding conductor isn't included with the supply circuit to the separate structure.D. Ground-fault protection of equipment is provided on the supply side of the feeder.10.b. A service disconnection means must be installed adjacent to, within sight of, and no more than_______ feet from a mobile home.A. 20B. 30C. 10D. 50
Chapter 18 Solutions
Electrical Wiring Residential
Ch. 18 - a. What circuit supplies the workshop lighting?...Ch. 18 - Prob. 2RCh. 18 - a. How is EMT fastened to masonry? _______________...Ch. 18 - What type of luminaires are installed on the...Ch. 18 - Prob. 5RCh. 18 - To what circuit are the smoke detectors connected?...Ch. 18 - Is it a Code requirement to connect smoke...Ch. 18 - Prob. 8RCh. 18 - Prob. 9RCh. 18 - Prob. 10R
Ch. 18 - Adjustment factors for conductor ampacities must...Ch. 18 - Prob. 12RCh. 18 - Prob. 13RCh. 18 - Calculate the total current draw of Circuit A17 if...Ch. 18 - Prob. 15RCh. 18 - A conduit body may contain splices if marked with...Ch. 18 - What size box would you use where Circuit A17...Ch. 18 - List the proper trade size of electrical metallic...Ch. 18 - According to the Code, what trade size EMT is...Ch. 18 - a. When more than three current-carrying...Ch. 18 - Prob. 21RCh. 18 - For laundry equipment in basements, what sort of...Ch. 18 - Prob. 23RCh. 18 - A Type NM cable carries a branch circuit to the...Ch. 18 - Prob. 25RCh. 18 - The following is a layout of the lighting circuits...Ch. 18 - Prob. 27RCh. 18 - Prob. 28R
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
The current source in the circuit shown generates the current pulse
Find (a) v (0); (b) the instant of time gr...
Electric Circuits. (11th Edition)
Identify the type of input and output configuration for each diff-amp in Figure 18-35.
Electronics Fundamentals: Circuits, Devices & Applications
With respect to the circuit in Fig. 5.90, (a) employ Thévenin’s theorem to determine the equivalent network see...
Loose Leaf for Engineering Circuit Analysis Format: Loose-leaf
What is the color code for a 365- five-band precision resistor with a tolerance of 5 percent?
ELECTRICITY FOR TRADES (LOOSELEAF)
A constant voltage of 10V is applied to a 50H inductance, as shown in Figure P3.51 Figure P3 51 The current in ...
Electrical Engineering: Principles & Applications (7th Edition)
Design an ideal inverting op-amp circuit such that the voltage gain is Av=25 . The maximum current in any resis...
Microelectronics: Circuit Analysis and Design
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- If you use 600-volt rated conductors for Class 2 wiring, does the Code permit pulling these conductors through the same raceway as the power conductors? (Yes) (No) (Circle the correct answer.) Give the NEC section number. ____________arrow_forwardDoes the NEC allow metal raceways to be used with nonmetallic boxes? Yes __________ No __________, NEC __________arrow_forwardThe point of attatchment of the service drop conductors to a building must not be less than ______ ft above finish gradearrow_forward
- Which of the following is a term missing from the National Electrical Code but used by manufacturers of equipment that's suitable for use as service equipment? Micro-grid Selective coordination Neutral disconnect link Grounding triad The _______ is required to be connected to the grounded conductor of the sensitive electronic system on the line side of the separately derived system disconnecting means. main bonding jumper equipment grounding terminal bus neutral ground strap neutral disconnect linkarrow_forwardwhat section of the code prohibits supporting telephone wires from raceways that contain light or power conductors.arrow_forwardComplete the wiring diagram for the Recreation Room. Follow the suggested cable layout. Use colored pencils or pens to identify the various colors of the conductor insulation.arrow_forward
- 6. Which of the following is a condition that a liquidtight flexible metal conduit must meet in order to be suitable as an equipment grounding conductor? A. The conduit is terminated in listed fittings.B. For trade sizes 3/4 through 1 1/4, the conduit conductors contained in the conduit are protected by overcurrent devices rated at 20 amperes or less.C. The combined length of the conduit and other tubing and conduit in the same ground-fault path exceeds six feet. D. For trade sides 3/8 through 1/2, the circuit conductors contained in the conduit are protected by overcurrent devices rated not more than 60 amperes. 7. You're going to connect a surge protection device to a separately derived electrical system. In this situation, the surge protection device should be connected at A. the load side of the first overcurrent protection device. B. the input to the transformer's primary winding.C. the end of the shortest branch circuit.D. the first connected IT cabinet. 8. What is another term…arrow_forwardA ______ is a raceway containing the service entrance conductors that is run through the roof of a building to a height sufficient to obtain the necessary clearances for the service-drop conductors. a. service lateralb. mast-type service entrancec. service pointarrow_forward5. If a separate, wire-type equipment grounding conductor (EGC) is used for any reason, the EGC of a grounding-type receptacle must be connected to which of the following?A. The grounding terminal bar outside the service equipment enclosure in a grounded systemB. An EGC that's part of another branch circuit that originates from where the branch circuit for the receptacle originatesC. Any accessible point on the grounding electrode conductorD. The service conductor outside the service equipment enclosure in an ungrounded systemarrow_forward
- Is it always necessary to attach the bare equipment grounding conductor of a nonmetallic-sheathed cable to the green hexagon-shaped grounding screw on a receptacle? Explain.arrow_forwarda. Does the circuit for the Master Bedroom have a grounded circuit conductor? ____________________ b. Does it have an equipment grounding conductor? ____________________ c. Explain the difference between a grounded conductor and an equipment grounding conductor. ____________________ ____________________arrow_forward18. Which of the following would help avoid the choke effect in grounding electrode conductors?A. Installing a main bonding jumperB. Using an approved polyvinyl chloride conduitC. Applying solder to the connectionD. Using bonding bushes on the ends of the racewayarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Types of Protective Relays and Design Requirements, Part 1a.; Author: GeneralPAC: Power System Tutorials;https://www.youtube.com/watch?v=JYil4T5VSDM;License: Standard Youtube License