Textbook Question
Chapter 19.2, Problem 18R
- a. How much power in watts would the two elements in problem 17 use if connected to 220 volts? Show calculations.
- b. What is the current draw at 220 volts? Show calculations.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Explain and draw a diagram of 3 wattmeter method?
Determine the power provided by the 20-volt source in the circuit below. Indicate if the 20-volt supply is supplying power to the circuit or absorbing power from the circuit.
Circuit 1 – Lighting Load by the Area Method
a. Determine the wattage required per square area. b. Determine the current load (230 volts) c. Compute the actual lighting load d. Solve the actual current load e. Determine the size of the branch Circuit wire. f. Determine the size of conduit Pipe. g. Determine the size of size or Rating of the branch circuit Protection
Chapter 19 Solutions
Electrical Wiring Residential
Ch. 19.1 - Does a jet pump have any electrical moving parts...Ch. 19.1 - Prob. 2RCh. 19.1 - Where is the jet of the pump located?...Ch. 19.1 - Prob. 4RCh. 19.1 - Prob. 5RCh. 19.1 - Prob. 6RCh. 19.1 - Prob. 7RCh. 19.1 - What is compressed in the water storage tank?...Ch. 19.1 - Explain the difference between a 2-wire...Ch. 19.1 - Prob. 10R
Ch. 19.1 - Why is a 240-volt motor preferable to a 120-volt...Ch. 19.1 - How many amperes does a 1-horsepower, 240-volt,...Ch. 19.1 - What size are the conductors used for this branch...Ch. 19.1 - Prob. 14RCh. 19.1 - What provides the running overload protection for...Ch. 19.1 - What is the maximum ampere setting permitted for...Ch. 19.1 - Prob. 17RCh. 19.1 - Because the controller contains the motor starting...Ch. 19.1 - Prob. 19RCh. 19.1 - Proper pressure of the submersible pump system is...Ch. 19.1 - Fill in the data for a 16-ampere electric motor,...Ch. 19.1 - The NEC is very specific in its requirement that...Ch. 19.1 - Does the NEC allow submersible pump cable to be...Ch. 19.1 - Must the disconnect switch for a submersible pump...Ch. 19.1 - A metal well casing (shall) (shall not) be bonded...Ch. 19.2 - Prob. 1RCh. 19.2 - A major hazard involved with water heaters is that...Ch. 19.2 - Prob. 3RCh. 19.2 - The heating elements in electric water heaters are...Ch. 19.2 - An 80-gallon electric water heater is energized...Ch. 19.2 - Prob. 6RCh. 19.2 - For residential water heaters, the Consumer...Ch. 19.2 - An 80-gallon electric water heater has 60F...Ch. 19.2 - Approximately how long would it take to produce...Ch. 19.2 - Two thermostats are generally used in an electric...Ch. 19.2 - a. How many heating elements are provided in the...Ch. 19.2 - When does the lower heating element operate?...Ch. 19.2 - Prob. 14RCh. 19.2 - Prob. 15RCh. 19.2 - Prob. 16RCh. 19.2 - a. If both elements of the water heater in this...Ch. 19.2 - a. How much power in watts would the two elements...Ch. 19.2 - A condominium owner complains of not getting...Ch. 19.2 - For a single, nonmotor-operated electrical...Ch. 19.2 - A 7000-watt resistance-type heating appliance is...Ch. 19.2 - Prob. 22R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- For ballpark calculations, the wattage output of a 240-volt electric furnace connected to a 208-volt supply will be approximately 75% of the wattage output had the furnace been connected to a 240-volt supply. In problem 13, calculate the wattage output of (a), (b), and (c) if connected to 208 volts. ____________________________________________ _______________________________________________________________________ _______________________________________________________________________ _______________________________________________________________________arrow_forwardA 100-W driveaway light bulb is on 10 hours per day. Assuming the power company charges 10 cents for each kilowatt-hour of electricity used. estimate the annual cost to operate the bulb. * Draw the diagramarrow_forwardIf the 50 ohm resistor is replaced by a variable load resistor, determine the maximum power delivered to the load.arrow_forward
- A condominium owner complains of not getting enough hot water. The serviceman checks the voltage at the water heater and finds the voltage to be 208 volts. The serviceman checks further and finds the electrical service on the building to be a 120/208-volt, three-phase, 4-wire system. The main electrical panelboard for each condominium unit is fed with a 3-wire supply. The nameplate on the electric water heater is marked 4500 watts, 240 volts. What is the wattage output of the heating element in this water heater when connected to a 208-volt supply? _____________________arrow_forwardWhat is the calculated load when fixed electric heating is used in a residence? (220.51)arrow_forwardA one watt 470-ohm resistor is connected to 24 volts. Is the resistor operating within its power rating?arrow_forward
- You are an electrician working in an industrial plant. The company is constructing a maintenance shop located 225 feet from the main plant electrical system. You are to install a 400-ampere three-phase wire system in the new maintenance shop. The service is supplied by the existing plant service. The voltage is 480 volts and the voltage drop is to be kept at 3% or below at full load. The conductors are to be aluminum. Determine the wire size needed for the 400-ampere service in accordance with the National Electrical Code. Assume that the conductors have type THWH insulation. (Note: As a general rule, for each 100 feet of conductor length the wire size is increased one standard size because of voltage drop.)arrow_forwardDetermine the total current flow in a lamp having 220 volt current supply, a fan of 240 volt supply and a hair dryer having 120 volts with a resistance of 12 ohms. Show solution .arrow_forward1-Calculate the electricity bill as per the table given 2- nested if formula has to be used to apply various conditions for all tariff blocks 3- for two tariff blocks formula is already applied so you have to do for the remaining tariff blockarrow_forward
- Is 5222 watts power rated equipment work if it is connected to a wire size no.6? Let voltage source =240 volts.arrow_forwardwhere did you get the 746 watts?arrow_forwardWhat is the current flowing on the 9-ohm resistor if the source voltage is placed at 16 volts? Note: Answer should be in A unit.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
What is an electric furnace and how does it work?; Author: Fire & Ice Heating and Air Conditioning Inc;https://www.youtube.com/watch?v=wjAWecPGi0M;License: Standard Youtube License