STRUCTURAL ANALYSIS (LL)
6th Edition
ISBN: 9780357030967
Author: KASSIMALI
Publisher: CENGAGE L
expand_more
expand_more
format_list_bulleted
Question
Chapter 2, Problem 12P
To determine
Find the external wind pressure acting on the roof of the building.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Determine the external wind pressure on the roof of the rigid-gabled frame of a school building shown in Fig. P2.13. The structure is located in a suburb of Chicago, Illinois, where the terrain is representative of exposure B and the basic wind speed for risk category III buildings is 51 mys. Assume the wind direction is normal to the ridge as shown. Use Kd 50.85 for main wind-force resisting systems, and Ke =1.
Determine the external wind pressure on the roof of the rigid gabled frame of a nonessential industrial building shown in Fig. 2.13(a). The structure is located in a suburb of Boston, Massachusetts, where the terrain is representative of exposure B. The wind direction is normal to the ridge of the frame as shown.
Determine the external wind pressure on the roof of the rigid-gabled frame of an apartment building shown in Fig. P2.12. The building is located in the Los Angeles area of California, where the terrain is representative of exposure B. The wind direction is normal to the ridge as shown. Use Kd 50.85 for main wind-force resisting systems, and Ke 51.
Chapter 2 Solutions
STRUCTURAL ANALYSIS (LL)
Knowledge Booster
Similar questions
- Determine the external wind pressure on the roof of the rigid-gabled frame of a building for an essential disaster operation center shown in Fig. P2.14. The building is located in Kansas City, Missouri, where the terrain is representative of exposure C and the basic wind speed for risk category IV buildings is 120 mph. Assume the wind direction is normal to the ridge, as shown in the figure. Use Kd 50.85 for main wind-force resisting systems, and Ke =1arrow_forwardDetermine the external wind pressure on the roof of the rigid-gabled frame of an apartment building shown in Fig. P2.12. The building is located in the Los Angeles area of California, where the terrain is representative of exposure B. The wind direction is normal to the ridge as shown.arrow_forwardThe floor system of a gymnasium consists of a 130- mm-thick concrete slab resting on four steel beams (A = 9,100 mm2) that, in turn, are supported by two steel girders (A = 25,600 mm2), as shown in Fig. P2.7. Determine the dead loads acting on beam BF and girder AD.arrow_forward
- Consider the cantilever beam subject to the concentrated load shown in Fig. below. Determine the maximum shearing stress due to V in the beam and also determine the shearing stress 25 mm from the top surface of the beam at a section adjacent to the supporting wall. 50 mm 50 kN 125 mm N.A. 2 m 58.7 mm 50 mm 200 mmarrow_forwardThe roof of a single-story storage building, shown in Fig. P2.1, is subjected to a uniformly distributed load of 0.96 kPa over its surface area. Determine the loads acting on the floor beam BE and the girder AC of the framing system.arrow_forwardQ2/ A cylindrical barrier holds water, as shown in Fig.1, the contact between cylinder and the wall is smooth. Consider a Im length of cylinder, determine the weight of the cylinder and the force exerted against the wall, take y, = 9790 N/m³. Fig. 1 TIL ... r-2marrow_forward
- EXAMPLE 7-1 = The beam shown in Fig. 7-10a is made of wood and is subjected to a resultant internal vertical shear force of V 3 kN. (a) Determine the shear stress in the beam at point P, and (b) compute the maximum shear stress in the beam. 50 mm 125 mm V= 3 kN 100 mm 37.5 mm (a)arrow_forwardDetermine the design snow loads for the roof of the gabled frame of an apartment building shown in Fig. 2.13(a). The building is located in Chicago, Illinois, where the ground snow load is 25 psf. Because of several trees near the structure,assume the exposure factor is Ce =1.arrow_forwardProblem 1) For the beam shown in the figure below has a width of 150 mm and height of 300 mm: B. ) Determine the flexural stress at a point 50 mm from the top of the beam's cross section and located at 2 meters from A. 112AN C 101Nm 25 m Fig. 6-29arrow_forward
- A wall form 8 ft high is filled with 150 lb per cu ft concrete at a tempera- ture of 60°F. The concrete is Type I with a retarder. Concrete will be placed with normal internal vibration to a depth of less than 4 ft. The concrete rate of placement will be 10 ft per hr. 12 ft 5.3 ft P=793 lb per sq ft Top of wallarrow_forwardThe roof system of an office building consists of a 4 in. thick reinforced concrete slab resting on four steel beams( 16.2 in. ) 52 A, which are supported by two steel girders ( 42.9 in.) 5 2 A . The girders, in turn, are supported by four columns, as shown in Fig. P2.8. Determine the dead loads acting on the girder AG Steel girder (A=42.9 in.²) Steel floor beam (A= 16.2 in.²) FIG. P2.8, P2.11 E 20 ft- B -Steel D column 4 in. concrete slab 3 at 9 ft = 27 ft Farrow_forwardThe roof system of an office building consists of a 4 in. thick reinforced concrete slab resting on four steel beams( 16.2 in. ) 5 2 A , which are supported by two steel girders ( 42.9 in. ) 5 2 A . The girders, in turn, are supported by four columns, as shown in Fig. P2.8. Determine the dead loads acting on the girder AGarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you