Three loads are connected in parallel across a single-phase source voltage of
Load 1 absorbs 15 kW and 6.667 kvar;
Load 2 absorbs 3 kVA at O.96PF leading;
Load 3 absorbs 15 kW at unity power factor.
Calculate the equivalent impedance, Z, for the three parallel loads, for two cases:
(i) Series combination of R and X, and (ii) parallel combination of R and X.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Circuit elements with an inductance of 200 mH, a capacity of 50 μF and a resistance of 10 Ω connected in parallel. if we apply average value of 198 V sinusoidal AC voltage to the system . Find the line current, impedance and phase angle of the circuit. (Take Frequency in 60 Hz)
A residential four-wire system supplies power at 220 V rms to the following single-phase appliances: On the first phase, there are ten 60-W bulbs. On the second phase, there is a 1-kW vacuum cleaner with a power factor of 0.9. On the third phase, there are ten 23-W compact fluorescent lamps with power factor of 0.61. Find a. The current in the neutral wire. b. The real, reactive, and apparent power for each phase.
A sigle-phase inductive load feeding from a 4,600 V rms supply, absorbs 600 kW at a laggingpower factor of 0.9. Determine the reactive power drawn by the load as well as R and X(a) if the load consists of R and X in series;(b) if the load consists of R and X in parallel.
Chapter 2 Solutions
Power System Analysis and Design (MindTap Course List)
Ch. 2 - The rms value of v(t)=Vmaxcos(t+) is given by a....Ch. 2 - If the rms phasor of a voltage is given by V=12060...Ch. 2 - If a phasor representation of a current is given...Ch. 2 - Prob. 2.4MCQCh. 2 - Prob. 2.5MCQCh. 2 - Prob. 2.6MCQCh. 2 - Prob. 2.7MCQCh. 2 - Prob. 2.8MCQCh. 2 - Prob. 2.9MCQCh. 2 - The average value of a double-frequency sinusoid,...
Ch. 2 - The power factor for an inductive circuit (R-L...Ch. 2 - The power factor for a capacitive circuit (R-C...Ch. 2 - Prob. 2.13MCQCh. 2 - The instantaneous power absorbed by the load in a...Ch. 2 - Prob. 2.15MCQCh. 2 - With generator conyention, where the current...Ch. 2 - Consider the load convention that is used for the...Ch. 2 - Prob. 2.18MCQCh. 2 - The admittance of the impedance j12 is given by...Ch. 2 - Consider Figure 2.9 of the text, Let the nodal...Ch. 2 - The three-phase source line-to-neutral voltages...Ch. 2 - In a balanced three-phase Y-connected system with...Ch. 2 - In a balanced system, the phasor sum of the...Ch. 2 - Consider a three-phase Y-connected source feeding...Ch. 2 - For a balanced- load supplied by a balanced...Ch. 2 - A balanced -load can be converted to an...Ch. 2 - When working with balanced three-phase circuits,...Ch. 2 - The total instantaneous power delivered by a...Ch. 2 - The total instantaneous power absorbed by a...Ch. 2 - Under balanced operating conditions, consider the...Ch. 2 - One advantage of balanced three-phase systems over...Ch. 2 - While the instantaneous electric power delivered...Ch. 2 - Given the complex numbers A1=630 and A2=4+j5, (a)...Ch. 2 - Convert the following instantaneous currents to...Ch. 2 - The instantaneous voltage across a circuit element...Ch. 2 - For the single-phase circuit shown in Figure...Ch. 2 - A 60Hz, single-phase source with V=27730 volts is...Ch. 2 - (a) Transform v(t)=75cos(377t15) to phasor form....Ch. 2 - Let a 100V sinusoidal source be connected to a...Ch. 2 - Consider the circuit shown in Figure 2.23 in time...Ch. 2 - For the circuit shown in Figure 2.24, compute the...Ch. 2 - For the circuit element of Problem 2.3, calculate...Ch. 2 - Prob. 2.11PCh. 2 - The voltage v(t)=359.3cos(t)volts is applied to a...Ch. 2 - Prob. 2.13PCh. 2 - A single-phase source is applied to a...Ch. 2 - Let a voltage source v(t)=4cos(t+60) be connected...Ch. 2 - A single-phase, 120V(rms),60Hz source supplies...Ch. 2 - Consider a load impedance of Z=jwL connected to a...Ch. 2 - Let a series RLC network be connected to a source...Ch. 2 - Consider a single-phase load with an applied...Ch. 2 - A circuit consists of two impedances, Z1=2030 and...Ch. 2 - An industrial plant consisting primarily of...Ch. 2 - The real power delivered by a source to two...Ch. 2 - A single-phase source has a terminal voltage...Ch. 2 - A source supplies power to the following three...Ch. 2 - Consider the series RLC circuit of Problem 2.7 and...Ch. 2 - A small manufacturing plant is located 2 km down a...Ch. 2 - An industrial load consisting of a bank of...Ch. 2 - Three loads are connected in parallel across a...Ch. 2 - Prob. 2.29PCh. 2 - Figure 2.26 shows three loads connected in...Ch. 2 - Consider two interconnected voltage sources...Ch. 2 - Prob. 2.35PCh. 2 - Prob. 2.36PCh. 2 - Prob. 2.37PCh. 2 - Prob. 2.38PCh. 2 - Prob. 2.39PCh. 2 - A balanced three-phase 240-V source supplies a...Ch. 2 - Prob. 2.41PCh. 2 - A balanced -connected impedance load with (12+j9)...Ch. 2 - A three-phase line, which has an impedance of...Ch. 2 - Two balanced three-phase loads that are connected...Ch. 2 - Two balanced Y-connected loads, one drawing 10 kW...Ch. 2 - Three identical impedances Z=3030 are connected in...Ch. 2 - Two three-phase generators supply a three-phase...Ch. 2 - Prob. 2.48PCh. 2 - Figure 2.33 gives the general -Y transformation....Ch. 2 - Consider the balanced three-phase system shown in...Ch. 2 - A three-phase line with an impedance of...Ch. 2 - A balanced three-phase load is connected to a...Ch. 2 - What is a microgrid?Ch. 2 - What are the benefits of microgrids?Ch. 2 - Prob. CCSQCh. 2 - Prob. DCSQ
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A source supplies power to the following three loads connected in parallel: (1) a lighting load drawing 10kW. (2) an induction motor drawing 10kVA at 0.90 power factor lagging, and (3) a synchronous motor operating at 10hp,85 effIciency and 0.95 power factor leading (1hp=0.746kW). Determine the real, reactive, and apparent power delivered by the source. Also, draw the source power triangle.arrow_forwardThe instantaneous power absorbed by the load in a single-phase ac circuit, for a general R LC load under sinusoidal-steady-state excitation. is (a) Nonzero constant (b) Zero (c) Containing double-frequency componentsarrow_forwardThe power factor for an inductive circuit (R-L load), in which the current lags the voltage, is said to be (a) Lagging (b) Leading (c) Zeroarrow_forward
- In a balanced system, the phasor sum of the line-to-line voltages and the phasor sum of the line-to-neutral voltages are always equal to zero. (a) False (b) Truearrow_forwardIs the power factor in Question 6 a leading or lagging power factor? Explain your answer.arrow_forwardA residential four-wire system supplies power at220 V rms to the following single-phase appliances:On the first phase, there are ten 75-W bulbs. On thesecond phase, there is a 750-W vacuum cleaner with apower factor of 0.87. On the third phase, there are ten40-W fluorescent lamps with power factor of 0.64.Finda. The current in the netural wire.b. The real, reactive, and apparent power for eachphase.arrow_forward
- Visible power of Z1 = |S1| = 16 kVA and at 0.8 back power factor; Visible power of Z2 = |S2| = 25 kVA and operates at unit power factor; Loads ZW = 5 + j26ohm/conductor is connected to the source by transmission line; VL = 3.8 kV Find the visible power of source,power factor and rms of sourcearrow_forwardWhat is the total apparent, reactive, and real power of the system? Also, determine the power factor.arrow_forwardFind the rms value of I0 in the unbalanced three-phase circuit shown.arrow_forward
- Find the complex power for the following: Vrms= 200 ∠ 30∘ V, Z= 40+ j60 Ω in addition formarrow_forwardBetween the terminals a and b in the figure, there is a load formed by connecting the resistor R0 and inductance L0 in series. The amplitude of the voltage Vs (t) is √2 150 volt phase angle Qs = 0 degree period T = 200π microseconds. Since R = 300ohm and C = 1 microfarad A) If the load phase angle QL = 30 degrees, find the values of R0 and L0 that enable the load to draw the maximum average power from the circuit. =? B) Calculate the average power on the load. =?arrow_forwardAn industrial installation has a power factor of 0.85 in backward. The demand is 150 KVA, and the operating voltage is 4800 V at 60 Hz. What should be done to bring the power factor to 0.95 in lagging? Indicate what you would connect and with what three-phase power. If the connection of the element to be added is in delta, indicate its reactance and the value of its capacitance or inductance. capacitance or inductance.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage LearningDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
What is the Difference Between Single Phase and Three Phase???; Author: Electrician U;https://www.youtube.com/watch?v=FEydcr4wJw0;License: Standard Youtube License