Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN: 9781305632134
Author: J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 2, Problem 2.8MCQ
To determine
The average power in the single-phase ac circuit for sinusoidal-steady-state excitationwith a purely inductive load.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A 120V adjustable frequency ac source is connected in series with a resistor, an inductor, and a capacitor. At 60Hz, the resistance is 5 ohms, the inductive reactance is 3 ohms, and the capacitive reactance is 4 ohms. Compute:
(a)load impedance at 60Hz
(b) value of the capacitance and inductance
Explain each step. Please recheck
Find the ff. on the AC circuit below having a 120Vrms as a signal source V1.
a.) Total Impedance ZT
b.) Current Ic , IL & IR
c.) Current Total IT
d.) Phasor angle
e.) Voltage across each branch. VR, Vc, VL
f.) Draw the phasor diagram of the circuit with complete label.
g.) Plot the sinusoidal wave indicating the phase angle, showing which are lagging or leadingNote: (see attached image for the diagram. please answer it based on your knowledge. thank you so much!)
Impedance of AC circuit and Admittance of AC circuitSHOW THE CIRCUIT USING ANY SOFTWARE OR YOU CAN DRAW IT MANUAALYY thNAKSS
Chapter 2 Solutions
Power System Analysis and Design (MindTap Course List)
Ch. 2 - The rms value of v(t)=Vmaxcos(t+) is given by a....Ch. 2 - If the rms phasor of a voltage is given by V=12060...Ch. 2 - If a phasor representation of a current is given...Ch. 2 - Prob. 2.4MCQCh. 2 - Prob. 2.5MCQCh. 2 - Prob. 2.6MCQCh. 2 - Prob. 2.7MCQCh. 2 - Prob. 2.8MCQCh. 2 - Prob. 2.9MCQCh. 2 - The average value of a double-frequency sinusoid,...
Ch. 2 - The power factor for an inductive circuit (R-L...Ch. 2 - The power factor for a capacitive circuit (R-C...Ch. 2 - Prob. 2.13MCQCh. 2 - The instantaneous power absorbed by the load in a...Ch. 2 - Prob. 2.15MCQCh. 2 - With generator conyention, where the current...Ch. 2 - Consider the load convention that is used for the...Ch. 2 - Prob. 2.18MCQCh. 2 - The admittance of the impedance j12 is given by...Ch. 2 - Consider Figure 2.9 of the text, Let the nodal...Ch. 2 - The three-phase source line-to-neutral voltages...Ch. 2 - In a balanced three-phase Y-connected system with...Ch. 2 - In a balanced system, the phasor sum of the...Ch. 2 - Consider a three-phase Y-connected source feeding...Ch. 2 - For a balanced- load supplied by a balanced...Ch. 2 - A balanced -load can be converted to an...Ch. 2 - When working with balanced three-phase circuits,...Ch. 2 - The total instantaneous power delivered by a...Ch. 2 - The total instantaneous power absorbed by a...Ch. 2 - Under balanced operating conditions, consider the...Ch. 2 - One advantage of balanced three-phase systems over...Ch. 2 - While the instantaneous electric power delivered...Ch. 2 - Given the complex numbers A1=630 and A2=4+j5, (a)...Ch. 2 - Convert the following instantaneous currents to...Ch. 2 - The instantaneous voltage across a circuit element...Ch. 2 - For the single-phase circuit shown in Figure...Ch. 2 - A 60Hz, single-phase source with V=27730 volts is...Ch. 2 - (a) Transform v(t)=75cos(377t15) to phasor form....Ch. 2 - Let a 100V sinusoidal source be connected to a...Ch. 2 - Consider the circuit shown in Figure 2.23 in time...Ch. 2 - For the circuit shown in Figure 2.24, compute the...Ch. 2 - For the circuit element of Problem 2.3, calculate...Ch. 2 - Prob. 2.11PCh. 2 - The voltage v(t)=359.3cos(t)volts is applied to a...Ch. 2 - Prob. 2.13PCh. 2 - A single-phase source is applied to a...Ch. 2 - Let a voltage source v(t)=4cos(t+60) be connected...Ch. 2 - A single-phase, 120V(rms),60Hz source supplies...Ch. 2 - Consider a load impedance of Z=jwL connected to a...Ch. 2 - Let a series RLC network be connected to a source...Ch. 2 - Consider a single-phase load with an applied...Ch. 2 - A circuit consists of two impedances, Z1=2030 and...Ch. 2 - An industrial plant consisting primarily of...Ch. 2 - The real power delivered by a source to two...Ch. 2 - A single-phase source has a terminal voltage...Ch. 2 - A source supplies power to the following three...Ch. 2 - Consider the series RLC circuit of Problem 2.7 and...Ch. 2 - A small manufacturing plant is located 2 km down a...Ch. 2 - An industrial load consisting of a bank of...Ch. 2 - Three loads are connected in parallel across a...Ch. 2 - Prob. 2.29PCh. 2 - Figure 2.26 shows three loads connected in...Ch. 2 - Consider two interconnected voltage sources...Ch. 2 - Prob. 2.35PCh. 2 - Prob. 2.36PCh. 2 - Prob. 2.37PCh. 2 - Prob. 2.38PCh. 2 - Prob. 2.39PCh. 2 - A balanced three-phase 240-V source supplies a...Ch. 2 - Prob. 2.41PCh. 2 - A balanced -connected impedance load with (12+j9)...Ch. 2 - A three-phase line, which has an impedance of...Ch. 2 - Two balanced three-phase loads that are connected...Ch. 2 - Two balanced Y-connected loads, one drawing 10 kW...Ch. 2 - Three identical impedances Z=3030 are connected in...Ch. 2 - Two three-phase generators supply a three-phase...Ch. 2 - Prob. 2.48PCh. 2 - Figure 2.33 gives the general -Y transformation....Ch. 2 - Consider the balanced three-phase system shown in...Ch. 2 - A three-phase line with an impedance of...Ch. 2 - A balanced three-phase load is connected to a...Ch. 2 - What is a microgrid?Ch. 2 - What are the benefits of microgrids?Ch. 2 - Prob. CCSQCh. 2 - Prob. DCSQ
Knowledge Booster
Similar questions
- The instantaneous power absorbed by the load in a single-phase ac circuit, for a general R LC load under sinusoidal-steady-state excitation. is (a) Nonzero constant (b) Zero (c) Containing double-frequency componentsarrow_forwardThe average value of a double-frequency sinusoid, sin2(t+), is given by (a) 1 (b) (c) Zeroarrow_forwardAn industrial load consisting of a bank of induction motors consumes 50 kW at a power factor of 0.8 lagging from a 220-V,60-Hz, single-phase source. By placing a bank of capacitors in parallel with the load, the resultant power factor is to be raised to 0.95 lagging. Find the net capacitance of the capacitor bank in F that is required.arrow_forward
- The rms value of v(t)=Vmaxcos(t+) is given by a. Vmax b. Vmax/2 c. 2Vmax d. 2Vmaxarrow_forwardThe power factor angle of a purely inductive circuit is 0 degrees Select one: True Falsearrow_forwardThe following is given for a series R-L-C circuit: resistor (R) = 8 Ohms, an inductor (L) = 32 mH and a capacitor (C) = 800uF. The circuit is supplied by a voltage source of e = 120 sin (125t) Volts. What is the angular frequency of the ac source? What is the circuit impedance? What is the power factor? What is the real power of the circuit?arrow_forward
- The impedance ZL in the circuit is adjusted for maximum average power transfer to ZL. The internal impedance of the sinusoidal voltage source is 4+j7 Ω. 1. a) What is the maximum average power delivered to ZL?2. b) What percentage of the average power delivered to the lineartransformer is delivered to ZL?arrow_forwardWhich component of impedance is not dependent on the frequency of the source of voltage? A. capacitance reactance B. inductive reactance C. resistance D. all are independent of the frequency of the sourcearrow_forwardFind the ff. on the AC circuit below having a 120Vrms as a signal source V1. a.) Total Impedance ZT b.) Current Ic , IL & IR c.) Current Total IT d.) Phasor angle e.) Voltage across each branch. VR, Vc, VL f.) Draw the phasor diagram of the circuit with complete label. g.) Plot the sinusoidal wave indicating the phase angle, showing which are lagging or leadingNote: (see attached image for the diagram and question. please answer it based on your knowledge. thank you so much!)arrow_forward
- If a current 5.0 A lags the applied voltage 230 V by an angle ϕ, it can be resolved into two components, OA in phase with the voltage and OB lagging by 90°. If the phasor diagram in to a circuit possessing resistance and inductance in series, OA and OB must not be labelled and respectively. It has become the practice to say that the power factor is laggingwhen the current lags the supply voltage, and leading when the current leads the supply voltage. This means that the supply voltage is regarded as the reference quantity. (a) A 30 μ F capacitor is connected across the applied voltage, 50 Hz supply. Calculate the reactance of 30 μ F capacitor connected across applied voltage (b) the reactance of the capacitor; (c) the current.arrow_forwardCircuit elements with an inductance of 200 mH, a capacity of 50 μF and a resistance of 10 Ω connected in parallel. if we apply average value of 198 V sinusoidal AC voltage to the system . Find the line current, impedance and phase angle of the circuit. (Take Frequency in 60 Hz)arrow_forwardA 120V adjustable frequency ac source is connected in series with a resistor, an inductor, and a capacitor. At 60Hz, the resistance is 5 ohms, the inductive reactance is 3 ohms, and the capacitive reactance is 4 ohms. Compute: (a)load impedance at 60Hz (b) value of the capacitance and inductance Explain each step.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning