(a)
Interpretation:
The potential difference across each of the resistors is to be stated.
Concept introduction:
The potential difference which is also known by various names like voltage or electric potential difference is defined as the difference in electric potential between two specific points in an electric circuit.
(b)
Interpretation:
The magnitude of each current is to be stated.
Concept introduction:
The current can be defined as the amount of electric charge flowing through a particular section per unit time. Current through an element is directly proportional to the potential difference across that element in the circuit.
(c)
Interpretation:
The power dissipated by the resistor
Concept introduction:
The phenomenon which results in the generation of heat as a part of the product due to friction or resistance is termed as power dissipation.
(d)
Interpretation:
The potential difference between point
Concept introduction:
Potential difference which is also known by various names like voltage or electric potential difference is basically defined as the difference in electric potential between two points.
Trending nowThis is a popular solution!
Chapter 2 Solutions
PRINCIPLES OF INSTRUMENTAL ANALYSIS
- Suggest possible reasons for the difference between the experimental and calculated voltages.arrow_forwardCurrents up to 30 A can be carried by 10 gauge copper wire. (a) What is the resistance of 80 m of 10 gauge copper wire? 0.255 (b) What is the electric field in the wire when the current is 30 A? 95.62 mV/m (c) How long does it take for an electron to travel 80 m in the wire when the current is 30 A? 8.93e11arrow_forwardIn a wire, 7.23 x 1020 electrons flow past any point during 3.57 s. What is the magnitude I of the current in the wire? Aarrow_forward
- Direct currents are uniform and have uniform voltage. OTrue O Falsearrow_forwardResistivity measurements at 300 K show that an annealed metal single crystal has amonovacancy concentration CV = 10-9. When the same crystal is quenched from a hightemperature, the measurements indicate CV = 2x10-3. Calculate the temperature of thequench [Take Hf = 51.4 kJ/mol and R = 8.314 J/mol.K]. State any assumption involved. (5)(b) Explain why the esistivity of a metal is expected to be found more at room temperature after quenching. Hint: Use Matthiessen’s rule (find out by self-studying and cite thesource.)arrow_forwardA flashlight uses batteries that add up to 4.5 V and has a power output of 0.48 W. (a) How much current is drawn from the batteries?A(b) What is the effective resistance of the flashlight?Ωarrow_forward
- A circuit is constructed with a 6.00 V battery connected across a 2900.0 Ω resistor.(i) Determine the moles of electrons that flow through the circuit per second for 26.98 min.(ii) Determine the number of joules produced by the circuit for the 26.98 min.arrow_forwardThe forward-bias voltage (V) required to maintain a PN diode current (I) is a function of the temperature (T). (a) Derive an expression for δV/δT (b) What is a typical value for a silicon diode? (c) Compare the result of (b) with a numerical value extracted.arrow_forward(a) Metals may be coated or plated for a number of reasons – state three reasons.(b) In an electroplating operation, what volume (cm3) and weight (g) of zinc will be deposited ontoa cathodic workpart if 10 A of current is applied for one hour? C = 4.75 x 10-2 mm3/A-s, cathodeefficiency E = 95%, density of zinc = 7.15 g/cm3.arrow_forward
- 4)strip serves as the anode and is connected to the positive terminal of a power supply. The negative terminal of the power supply is connected to an insulated copper wire. An ammeter is placed in the circuit and the power supply is turned on. A current of 1.10 A flows for 6 min and 36 sec. During this time the mass loss of the metal is 0.109 g. What is the molar mass of the metal?arrow_forwardThe purity of a sample of K3Fe(CN)6 is determined using hydrodynamic voltammetry at a glassy carbon electrode. The following data were obtained for a set of calibration standards. A sample of impure K3Fe(CN)6 is prepared for analysis by diluting a 0.264 g portion to volume in a 100 mL volumetric flask. The limiting current for the sample is 444 μA. a) What type of calibration method is used? b) What is the purity of this sample of K3Fe(CN)6 (FW=329.25 g/mol)?arrow_forwardThe purity of a sample of K3Fe(CN)6 is determined using hydrodynamic voltammetry at a glassy carbon electrode. The following data were obtained for a set of calibration standards. A sample of impure K3Fe(CN)6 is prepared for analysis by diluting a 0.264 g portion to volume in a 100 mL volumetric flask. The limiting current for the sample is 444 μA. a) What type of calibration method is used? (Internal Standard, External Standard, or Standard Addition?) b) What is the purity of this sample of K3Fe(CN)6 (FW=329.25 g/mol)?arrow_forward
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningPrinciples of Modern ChemistryChemistryISBN:9781305079113Author:David W. Oxtoby, H. Pat Gillis, Laurie J. ButlerPublisher:Cengage Learning
- Chemistry: Principles and PracticeChemistryISBN:9780534420123Author:Daniel L. Reger, Scott R. Goode, David W. Ball, Edward MercerPublisher:Cengage Learning