Chapter 2, Problem 2P
To determine
Find the axial load acting on column C of the framing system.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
3. The floor of an apartment building, shown in Fig. P2.3, is subjected to a uniformly distributed
load of 45 psf over its surface area. Determine the loads acting on the floor beams AF, BG, and
CH, and the girders AC and FH, of the framing system.
Given. A two-story OCBF shown in Fig. 3.40c that forms part of the building
frame system in SDC E. The axial loads on the ground floor brace B1 are as follows:
Dead load D= 30 kips
Live load L= 15 kips
Seismic force QE = ±80 kips
Snow load S= 0 kips
Hydrostatic load H = 0
The redundancy coefficient p = 1.1.
Mapped two-second såpectral acceleration, Sps = 0.826 g.
Required. Determine a pipe section for brace B1, ASTM A53 Grade B steel; F, =
35 ksi, F = 60 ksi
16 ft
16 ft
Figure
-15 ft
B2
B1
--
-15 ft
B2
B1
Ordinary concentric brace frame (OCBF) example.
Q2. Determine the force in each member of the double-pitch roof truss as shown in Fig.2.
State whether each member is in tension or compression.
3 m, 3 m
-4 m→-4 m--4 m-
1.75 kN
2 kN
1.5 kN
2 kN
_0.75 kN
6 m
1 kN
D
В
A
E
- 6 m.
6 m
-6 m.
Chapter 2 Solutions
Structural Analysis, Si Edition
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Similar questions
- 2-16. A truss is loaded as shown in Fig. P 2-15. Determine the resultant load on the truss. 5000 6000 2000 6 Ponels e 10' : 60' 1000 2-18. Determine the resultant of the parallel, coplanar force system shown in Fig. P 2-18 and locate it with respect to point A. 10" 200 300 4' FIG. P 2-18arrow_forward2-15. A truss is loaded as shown in Fig. P 2-15. Determine the resultant load on the truss. 5000 6000 2000 6 Panels 10' • 60' 10004arrow_forward4.19 and 4.20 Knowing that for the extruded beam shown the allowable stress is 120 MPa in tension and 150 MPa in compres- sion, determine the largest couple M that can be applied. 50 mm Fig. P4.19 MOLO 150 mm a hp 125 mm 125 mm M UE ■ R 80 mm 40 mm Fig. P4.20 M 54 mm ^ + 4)arrow_forward
- A doubly symmetrical I-section beam is reinforced by a flat plate attached to the upper flange as shown in Fig. P.10.3. If the resulting compound beam is subjected to a vertical shear load of 200 kN, determine the distribution of shear stress in the portion of the cross section that extends from the top of the plate to the ncutral axis. Calculate also the shcar force per unit length of bcam resisted by the shear connection between the plate and the flange of the I-section beam.arrow_forward524. A beam with an S380 X 74 section carries a total uniformly distributed load of 3W and a concentrated load W, as shown in Fig. P-524. Determine W if the flexura stress is limited to 120 MPa.arrow_forward38 RESULTANTS OF FORCE SYSTEMS 2-17. Determine the resultant of the parallel, coplanar force system in Fig. P 2-17. [$2-4 60b 100 60 E 30 200b /50 100b 200 / 300 40 120 FIG. P 2-17 6' 4' FIG. P 2-18 2-18. Determine the resultant of the parallel, coplanar force system shown in Fig. P 2-18 and locate it with respect to point A.arrow_forward
- The building in Fig. P1.1 is used for general office space. The slab is 10 in. thick. The beams are 16 in. wide and have a total depth of 20 in., the bay dimensions are 20 ft in the X direction and 25 ft in the Y direction, and the superimposed service dead load is 4 psf. Calculate the slab factored load in psf and the beam factored load in klf.arrow_forward6.13 Determine the force in each member of the roof truss shown. State whether each member is in tension (T) or compression (C). 6 m -6 m 6 m 1.2 kN 2.4 kN F 2.4 kN D 1.2 kN 7.5 m B E 9 m 9 m Fig. P6.13arrow_forwardFind the collapse load for the beam shown in the Fig. below. 2P 2P W=P/2 W=P/2 4m 6marrow_forward
- A B The truss system supports the hanging beam with distributed loading as shown. 3m Joint A is a pin connection and joint Eis a roller. E 니m 4m 3m Problem #1 With w= 8 kN/m, which member of the truss is seeing the largest compressive force and what is its magnitude? Problem #2 With w= 8 kN/m, which member of the truss is seeing the largest tension force and what is its magnitude? Problem #3 If the maximum tension force the members of the truss can withstand is 35 kN and the maximum compressive force the members of the truss can withstand is 20 kN, calculate the largest w (kN/m) the system can support?arrow_forward#1.4 Determine the maximum tensile and compressive bending stresses in the beam shownarrow_forwardK1arrow_forward