Question
Chapter 20.1, Problem 4R
a.
To determine
Mention the maximum operating temperature for a type TW conductor.
b.
To determine
Mention the maximum operating temperature for a type THW conductor.
c.
To determine
Mention the maximum operating temperature for a type THHN conductor.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
10.a. Which of the following is a condition of the exception that allows the grounded conductor of feeders tobe used for grounding at separate buildings or structures?A. There are common electrically continuous metallic paths between the feeder source and the destination at the structure served.B. There are common electrically continuous nonmetallic paths between the equipment grounding conductor and the destinationat the structure served.C. An equipment grounding conductor isn't included with the supply circuit to the separate structure.D. Ground-fault protection of equipment is provided on the supply side of the feeder.10.b. A service disconnection means must be installed adjacent to, within sight of, and no more than_______ feet from a mobile home.A. 20B. 30C. 10D. 50
6. Which of the following is a condition that a liquidtight flexible metal conduit must meet in order to be suitable as an equipment grounding conductor?
A. The conduit is terminated in listed fittings.B. For trade sizes 3/4 through 1 1/4, the conduit conductors contained in the conduit are protected by overcurrent devices rated
at 20 amperes or less.C. The combined length of the conduit and other tubing and conduit in the same ground-fault path exceeds six feet.
D. For trade sides 3/8 through 1/2, the circuit conductors contained in the conduit are protected by overcurrent devices rated not more than 60 amperes.
7. You're going to connect a surge protection device to a separately derived electrical system. In this situation, the surge protection device should be connected at
A. the load side of the first overcurrent protection device. B. the input to the transformer's primary winding.C. the end of the shortest branch circuit.D. the first connected IT cabinet.
8. What is another term…
Which of the following statements about equipment grounding conductors (EGCs) is true?A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor.B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray.C. No current should be present in the EGC during normal operation.D. EGCs are required to be decreased in size to address voltage drop.
Chapter 20 Solutions
Electrical Wiring Residential
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Is it always necessary to attach the bare equipment grounding conductor of a nonmetallic-sheathed cable to the green hexagon-shaped grounding screw on a receptacle? Explain.arrow_forwardDescribe what the following conductor designation means when it is printed on the insulation; RHH/RHW,USEarrow_forwardSeven 8 AWG copper conductors are run in conduit. Each conductor has type THHN insulation. The conduit is located in an area with an ambient temperature of 138oF. What is the ampacity of each conductors?arrow_forward
- What size equipment grounding conductor is used with # 8 AWG nonmetallic-sheathed cable?arrow_forwarda. Does the circuit for the Master Bedroom have a grounded circuit conductor? ____________________ b. Does it have an equipment grounding conductor? ____________________ c. Explain the difference between a grounded conductor and an equipment grounding conductor. ____________________ ____________________arrow_forwardThe frames of ranges, wall-mounted ovens, counter-mounted cooking units, and clothes dryers under the conditions permitted for existing installations, ___ permitted to be connected to the grounded circuit conductor. Select one: a. shall not be b. can not c. may be d. shall bearrow_forward
- Eighty 16 AWG copper conductors with type THWN-2 insulation are to be run in a conduit. The conduit used in an area that has an ambient temperature of 120 F. What is the maximum ampacity of these conductors?arrow_forwardWhere insulated conductors are deflected within a wireway, either at the ends or where conduits, fittings, or other raceways or cables enter or leave the wireway, or where the direction of the wireway is deflected greater than ____, dimensions corresponding to one wire per terminal in Table 312.6(A) shall apply.arrow_forwardWhat is the maximum ampacity of a #8 copper conductor in a conduit with type THWN insulation used in an area with an ambient temperature of 50 degrees C?arrow_forward
- a. Must the metal frame of an electric clothes dryer be grounded? ___________ b. Is it permitted to ground the metal frame of an electric clothes dryer to the neutral conductor? ___________arrow_forwardA conductor with continuous white or gray covering shall be used only for the grounded circuit conductor.arrow_forwardThe white wire of a cable may be used to connect to a "hot" ungrounded circuit conductor only if ?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Demos: Dielectric breakdown; Author: Caltech's Feynman Lecture Hall;https://www.youtube.com/watch?v=2YrHh1ikefI;License: Standard Youtube License