Question
Chapter 20.2, Problem 12R
a.
To determine
State the required size of
b.
To determine
State the required size of
c.
To determine
State the required size of
d.
To determine
State the required size of
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Which of the following statements about equipment grounding conductors (EGCs) is true?A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor.B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray.C. No current should be present in the EGC during normal operation.D. EGCs are required to be decreased in size to address voltage drop.
1. Which of the following statements about equipment grounding conductors is true?A. Unacceptable equipment grounding conductors include conduit, tubing, and cable armor.B. They must be capable of withstanding the higher level of ground-fault current to perform their safety function.C. They increase voltages above ground potential on conductors and equipment enclosures during normal operation.D. When they're far from their associated circuit conductors, impedance values are kept as low as possible during ground-faultconditions.
4.a. The installation of motor controllers and combination load equipment is not permitted if the short-circuitcurrent rating of the equipment isA. equal to the available short-circuit current at the site of installation.B. not found on either of the nameplates.C. more than the available short-circuit current at the site of installation.D. less than the available short-circuit current at the site of installation.
4.b. In a(n) ___ bend, the conductor does not enter or leave an enclosure through the wall opposite itsterminals.a. Vb. Sc. L
Chapter 20 Solutions
Electrical Wiring Residential
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 2.a. What's defined as an assembly consisting of a service raceway, guy wires or braces, service head, andany fittings necessary for the termination and support of overhead service conductors?A. Drip loopB. Service lateralC. Service dropD. Service mast 2.b. What's likely to happen when connected parallel conductors are different lengths?A. An NEC violationB. Misidentification of conductor cablesC. An uneven distribution of currentD. Conductor terminationarrow_forward14. If the total circular mil area of the largest ungrounded service-entrance conductor for a service is 2000-kcmil copper, what is the minimum size required for a wire-type main bonding jumper for the service? a) 4/0 AWG copper b) 250-kcmil copper c) 350-kcmil copper d) 500-kcmil copper 15. The minimum-size grounded conductor for a service supplied by a grounded system shall not be smaller than the minimum size required for a(n)______. a) Equipment grounding conductor b) System bonding jumper c) Ungrounded conductor d) Grounding-electrode conductor Note: answer both the questions with proper explanation. As per bartleby honor code I can submit 3 questions. So please answer botharrow_forwarda. Does the circuit for the Master Bedroom have a grounded circuit conductor? ____________________ b. Does it have an equipment grounding conductor? ____________________ c. Explain the difference between a grounded conductor and an equipment grounding conductor. ____________________ ____________________arrow_forward
- a. How many feet of 2-conductor bell wire cable are required? ______ b. How many feet of 3-conductor bell wire cable are required? ______arrow_forwardUsing the above example, determine the wire size needed for the 400-ampere service in accordance with the National electrical Code. Assume that the conductors have type THWH insulation. (Note: As a general rule, for each 100 feet of conductor length the wire size is increased one standard size because of voltage drop.)arrow_forwardDefine an equipment grounding conductor.arrow_forward
- Define service-drop conductors.arrow_forwardList the methods by which an equipment grounding conductor is connected to a device box.arrow_forwarda. What size and type of conductors are installed for the service in this text? _____________ b. What size conduit is installed? _____________ c. What size grounding electrode conductor is installed? (not neutral) _____________ d. Is the grounding electrode conductor insulated, armored, or bare? _____________arrow_forward
- 4. Eight 10 AWG aluminum conductors with Type THWN insulation are installed in a single conduit. What is the maximum current-carrying capacity of these conductors? Assume an ambient temperature of .arrow_forwardA ____shall be used to connect the equipment grounding conductors, the service equipment enclosures, and where the system is grounded, the grounded service conductor to the grounding electrode. (a.) bus bar ( b.) 5/8” ground rod (c.) neutral conductor (d.) grounding electrode cond. For equipment rated 1200 amperes or more 600 volts or less, and over 6 feet wide, containing overcurrent devices, switching devices, or control devices, there shall be one entrance not less than ____inches wide and 6 ½ feet high at each end. (a.) 24 (b.) 36 (c.) 30 (d.) 48 When calculating the conductor fill for strut-type channel raceway with internal joiners, the raceway shall be permitted to be filled to _____% of the cross-sectional area. (a.) 20 ( c.) 30 (b.) 25 (d.) 40arrow_forward10.a. Which of the following is a condition of the exception that allows the grounded conductor of feeders tobe used for grounding at separate buildings or structures?A. There are common electrically continuous metallic paths between the feeder source and the destination at the structure served.B. There are common electrically continuous nonmetallic paths between the equipment grounding conductor and the destinationat the structure served.C. An equipment grounding conductor isn't included with the supply circuit to the separate structure.D. Ground-fault protection of equipment is provided on the supply side of the feeder.10.b. A service disconnection means must be installed adjacent to, within sight of, and no more than_______ feet from a mobile home.A. 20B. 30C. 10D. 50arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Types of House Wiring - Types of Electrical Wiring - Electrical Wiring; Author: Learning Engineering;https://www.youtube.com/watch?v=A5P-buWX-dA;License: Standard Youtube License