Concept explainers
a.
Draw the correct symbol for the description “Lighting panel”.
a.
Explanation of Solution
The symbol for the lighting panel is drawn and it is shown in Figure 1 as follows:
Conclusion:
Thus, the symbol for the given description is drawn.
b.
Draw the correct symbol for the description “Clock outlet”.
b.
Explanation of Solution
The symbol for the clock outlet is drawn and it is shown in Figure 2 as follows:
Conclusion:
Thus, the symbol for the given description is drawn.
c.
Draw the correct symbol for the description “Duplex outlet”.
c.
Explanation of Solution
The symbol for the duplex outlet is drawn and it is shown in Figure 3 as follows:
Conclusion:
Thus, the symbol for the given description is drawn.
d.
Draw the correct symbol for the description “Outside telephone”.
d.
Explanation of Solution
The symbol for the outside telephone is drawn and it is shown in Figure 4 as follows:
Conclusion:
Thus, the symbol for the given description is drawn.
e.
Draw the correct symbol for the description “Single-pole switch”.
e.
Explanation of Solution
The symbol for the single-pole switch is drawn and it is shown in Figure 5 as follows:
Conclusion:
Thus, the symbol for the given description is drawn.
f.
Draw the correct symbol for the description “Motor”.
f.
Explanation of Solution
The symbol for the motor is drawn and it is shown in Figure 6 as follows:
Conclusion:
Thus, the symbol for the given description is drawn.
g.
Draw the correct symbol for the description “Duplex outlet, split-wired”.
g.
Explanation of Solution
The symbol for the duplex outlet, split-wired is drawn and it is shown in Figure 7 as follows:
Conclusion:
Thus, the symbol for the given description is drawn.
h.
Draw the correct symbol for the description “Lampholder with pull switch”.
h.
Explanation of Solution
The symbol for the lampholder with pull switch is drawn and it is shown in Figure 8 as follows:
Conclusion:
Thus, the symbol for the given description is drawn.
i.
Draw the correct symbol for the description “Weatherproof outlet”.
i.
Explanation of Solution
The symbol for the weatherproof outlet is drawn and it is shown in Figure 9 as follows:
Conclusion:
Thus, the symbol for the given description is drawn.
j.
Draw the correct symbol for the description “Special-purpose outlet”.
j.
Explanation of Solution
The symbol for the special-purpose outlet is drawn and it is shown in Figure 10 as follows:
Conclusion:
Thus, the symbol for the given description is drawn.
k.
Draw the correct symbol for the description “fan outlet”.
k.
Explanation of Solution
The symbol for the fan outlet is drawn and it is shown in Figure 11 as follows:
Conclusion:
Thus, the symbol for the given description is drawn.
l.
Draw the correct symbol for the description “Range outlet”.
l.
Explanation of Solution
The symbol for the range outlet is drawn and it is shown in Figure 12 as follows:
Conclusion:
Thus, the symbol for the given description is drawn.
m.
Draw the correct symbol for the description “Power panel”.
m.
Explanation of Solution
The symbol for the power panel is drawn and it is shown in Figure 13 as follows:
Conclusion:
Thus, the symbol for the given description is drawn.
n.
Draw the correct symbol for the description “3-way switch”.
n.
Explanation of Solution
The symbol for the 3-way switch is drawn and it is shown in Figure 14 as follows:
Conclusion:
Thus, the symbol for the given description is drawn.
o.
Draw the correct symbol for the description “Push button”.
o.
Explanation of Solution
The symbol for the push button is drawn and it is shown in Figure 15 as follows:
Conclusion:
Thus, the symbol for the given description is drawn.
p.
Draw the correct symbol for the description “Thermostat”.
p.
Explanation of Solution
The symbol for the thermostat is drawn and it is shown in Figure 16 as follows:
Conclusion:
Thus, the symbol for the given description is drawn.
q.
Draw the correct symbol for the description “Electric door opener”.
q.
Explanation of Solution
The symbol for the electric door opener is drawn and it is shown in Figure 17 as follows:
Conclusion:
Thus, the symbol for the given description is drawn.
r.
Draw the correct symbol for the description “Multioutlet assembly”.
r.
Explanation of Solution
The symbol for the multioutlet assembly is drawn and it is shown in Figure 18 as follows:
Where,
Conclusion:
Thus, the symbol for the given description is drawn.
Want to see more full solutions like this?
Chapter 2 Solutions
Electrical Wiring: Residential
- The recessed fluorescent luminaires installed in the ceiling of the recreation room of this residence are connected with trade size flexible metal conduit. These flexible connections are commonly referred to as fixture whips. Does the flexible metal conduit provide adequate grounding for the luminaires, or must a separate equipment grounding conductor be installed? ________________arrow_forwarda. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to connect a receptacle in a dining room to one of the kitchen small-appliance circuits? _______________ What Code section applies to this situation? _______________ b. Are outdoor weatherproof receptacles permitted to be connected to a 20-ampere small-appliance circuit? _______________ c. Receptacles located above the countertops in the kitchen must be supplied by at least _______________ 20-ampere small-appliance circuits.arrow_forwardRefer to the specifications in the back of this text following Chapter 33. a. What electrical codes must be conformed to? ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ b. What is the wiring method to be used in the workshop? ________________________________________________________________________ c. What size conductors are to be used for the lighting branch circuits? ______________________ AWG the small-appliance branch circuits? ______________________ AWG d. What section of the specifications tells us the size of the service entrance to be installed for this residence?arrow_forward
- A residential air-conditioning unit is installed in the attic. a. Is a lighting outlet required? __________ b. What Code section applies? __________ c. If a lighting outlet is required, how shall it be controlled? __________ d. What Code section applies? __________ e. Is a receptacle outlet required? __________ f. What Code section applies? __________arrow_forwardWhy is it permissible to omit an electric space heater, water heater, and certain other 240-volt equipment when calculating the neutral service-entrance conductor for a residence? ____arrow_forwardIn order to wire a post light, a homeowner purchased some single-conductor cable that was marked as suitable for direct burial in the ground. A separate equipment grounding conductor to the post light was not carried. Instead, the bottom of the metal post, buried 2 ft (0.6 m) into the ground, was used as a ground for the post light. The inspector red tagged (turned down) the installation. Who is rightthe homeowner or the electrical inspector? Explain. ___________________ ___________________ ___________________arrow_forward
- Which of the following installations for a kitchen waste disposal that operates on a 15-ampere, 120-volt branch circuit requires AFCI protection? (Circle the correct answer.) a. The disposal operates by a switch that is installed above the kitchen counter. b. The disposal operates by a switch that is installed under the counter next to the disposal. c. Both (a) and (b) d. Neither (a) nor (b).arrow_forwardladder diagram for bottom half of a switched receptacle is to always be hot plus a duplex receptacle that is controlled from two locations using a coast 3-way wiring systemarrow_forward5. If a separate, wire-type equipment grounding conductor (EGC) is used for any reason, the EGC of a grounding-type receptacle must be connected to which of the following?A. The grounding terminal bar outside the service equipment enclosure in a grounded systemB. An EGC that's part of another branch circuit that originates from where the branch circuit for the receptacle originatesC. Any accessible point on the grounding electrode conductorD. The service conductor outside the service equipment enclosure in an ungrounded systemarrow_forward
- QUESTION 25 Type TC cable shall not be _____. a. installed where it will be exposed to physical damage b. all of these c. installed outside of a race-way or cable tray system, unless permitted in 336.10(4), 336.10(7), 336.10(9), and 336.10(10) d. used where exposed to direct rays of the sun, unless identified as sunlight resistantarrow_forwardThe NEC requires what type of unique protection for all 120-volt, 15- and 20-ampere branch-circuit outlets in bedrooms of residential homes? In which section of the NEC is this requirement found? _____________________arrow_forwardThe following is a layout of the lighting circuit for the Laundry, Powder Room, Rear Entry Hall, and Attic. Complete the wiring diagram using colored pens or pencils to indicate conductor insulation color. The GFCI receptacle in the Powder Room is not shown in the diagram because it is connected to a separate circuit, B21.arrow_forward
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT