How is auxiliary contact interlocking achieved on a reversing starter?
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
What safely feature does the conbination starter provide that individual motor starting assemblies do not?
what is the laddered circuit of forward-reversed motor control?
A selector switch and two - wire pilot device cannot be used to control a large motor directly but rather must be connected to a magnetic starter. Why this is true.?
Chapter 21 Solutions
Electric Motor Control
Ch. 21 - How is a change in the direction of rotation of a...Ch. 21 - Prob. 2SQCh. 21 - If a reversing control circuit contains...Ch. 21 - How is auxiliary contact interlocking achieved on...Ch. 21 - After the forward coil has been energized, is the...Ch. 21 - If a mechanical interlock is the only means of...Ch. 21 - If pilot lights are to indicate which coil is...Ch. 21 - What is the sequence of the operations if the...Ch. 21 - In place of the push buttons in Figure 214, draw a...Ch. 21 - From the elementary drawing in Figure 2110,...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Describe how pressure switches are connected to start and stop (a) small motors and (b) large motors.arrow_forwardWhat causes the overload of a starter to open and disable the power circuit?arrow_forwardWhat happens to a series connected direct current motor if its field winding opens at full load?arrow_forward
- When the high button is depressed in Figure 314, what prevents the high-speed starter from closing immediately?arrow_forwardHow many poles are required on motor starters for the following motors:(a)240-volt, single-phase induction motor,(b)440-volt, three-phase induction motor?arrow_forwardRefer to the circuit shown in Figure 105. Assume that the motor is running and an overload occurs, which causes the OL contact to open and disconnect coil M to stop the motor. What effect does the opening of the overload contact have on the pressure switch circuit?arrow_forward
- What is meant by the description separate winding two-speed motor?arrow_forwardwhat device is generally used to disconnect the start windings of a split phase motor for open type motors that are not hermatically sealed?arrow_forwardHow to avoid the effect of the high current at starting of the Motor? a. variable resistor is connected in series with Armature circuit b. variable resistor is connected in parallel with Armature circuit c. variable resistor is connected in series with field circuit d. None of the above Clear my choicearrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
Single Phase Induction Motor, How it works ?; Author: Lesics;https://www.youtube.com/watch?v=awrUxv7B-a8;License: Standard Youtube License