EBK 3N3-EBK: INDUSTRIAL MOTOR CONTROL
7th Edition
ISBN: 9780176919962
Author: Herman
Publisher: VST
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 28, Problem 2RQ
To determine
Whether the component is generally normally closed or open when it is used for the function of stop.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
When servicing transfer cases, all of the following are correct, except
For a given frame size, a three phase machines gives a higher output than a single phase machine.
Select one:
True
False
Using a double-acting cylinder a work piece is removed and tipped onto a conveyor belt.
Following are the sequence of operations
1.
The operation is to be started using a push button (use the label START PB). Include a stop push button (use the label STOP PB) to stop the
process at any time. (Use Memory ON circuit)
2.
An acknowledgement signal (S1- Limit switch) is required when the piston is fully extended, to ensure that the work piece has been tipped onto
the belt.
3.
The extension should be slower than the retraction (use flow control valve)
4.
The return stroke should be automatic.
a.
Design the Electro- Hydraulic Circuit with proper labeling. Include the components required
b.
Draw the Displacement -step diagram & Displacement -time diagram (include Cylinder, START PB, STOP PB, DCV and S1)
Chapter 28 Solutions
EBK 3N3-EBK: INDUSTRIAL MOTOR CONTROL
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- What exactly does the inability to resolve the stopping problem mean?arrow_forwardDescribe one of control section component which is used to operate double acting cylinder of having 3 position and 4 ports with the electrical, mechanical and manual method of actuation.arrow_forwardFLUID POWER SYSTEMSarrow_forward
- Name Section 5-2: Line Diagrams-Signals, Decisions, and Actions In the following application, a temperature switch controls a heating contactor and a flow switch is used to ensure there is enough air flow. If there is not enough air flow, an alarm is sounded. Complete the required information. 1. List all the signal devices in the circuit. 2. List all the action devices in the circuit. 3. List the decision part of the circuit that automatically sounds the alarm if there is a problem. 4. When the heating element is on during normal operation, is the flow switch open or closed? CIRCULATING 2 L1 FAN TEMPERATURE SWITCH TR HEATING ELEMENTS FLOW SWITCH -HOT AIR PADDLE AIR FILTER NORMALLY CLOSED FLOW SWITCH 65 ALARM (SOUNDS IF NO FLOW FOR 15 SECONDS OR MORE) Date HEATING CONTACTOR TR ON-DELAY TIMER SUPPLY AIR COLD AIR (3) TIME SET= 15 SEC © 2014 American Technical Publishers, Inc. All rights reservedarrow_forwardElectro-pneumatics Sequential Circuit Problem: Initial position all cylinder are retracted. Pressing the start pushbutton makes 5 cycles. After making 5 cycles lamp is energized for 3 secs. Cycle Operation: Cylinder A extend and hold the work piece. Cylinder B extend for 5 secs. Then retract. Cylinder A retract.arrow_forwardWhat would the value of c_1 and c_2 be?arrow_forward
- True or False: Holding down the <Shift> key during the CHAMFERcommand allows it to draw fillet curves.arrow_forwardHYDRAULICS & ELECTRO-HYDRAULICSarrow_forwardBending Tool Problem: Sheet metal is to be bended on a pneumatically actuated bending rig. After it has been clamped the piece is initially bent by a double-acting cylinder A and subsequently bent into the finished form by cylinder B. The sequence is initiated manually by a push button. The circuit must be so constructed that each time a start signal is given a full cycle is completed. Draw the pneumatic circuit diagram of the given problem Positional Sketch:arrow_forward
- Problem Description Components are to be continuously stamped with a stamping device. After the start button is pressed, the die is pushed down and the component is stamped. The die is to return to initial position after five (5) seconds. The sequence stops automatically after five (5) cycles. Start button should reset the counter. Inductive sensors S1 and S2 are used to check the fully retracted and extended positions of the cylinder. Draw the following: Pneumatic circuit diagram Electrical circuit diagramarrow_forwardTo program the motion of tool according scheme below you must write Current position Stop line PAST Drive line Si → SI Select one: S1, TANTO, S2 S1, ON, S2 S1, TLLFT, S2 Sj→ S2 None of the above S1, TO, S2 S1, PAST, S2 S1, TLRGT, S2arrow_forwardPlease helparrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningPrecision Machining Technology (MindTap Course Li...Mechanical EngineeringISBN:9781285444543Author:Peter J. Hoffman, Eric S. Hopewell, Brian JanesPublisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Precision Machining Technology (MindTap Course Li...
Mechanical Engineering
ISBN:9781285444543
Author:Peter J. Hoffman, Eric S. Hopewell, Brian Janes
Publisher:Cengage Learning