(a)

To determine

To Find:

The resistance and inductive reactance of the plant’s total load.

(a)

Expert Solution
Check Mark

Answer to Problem 18P

Resistance R=571Ω and inductive impedance XL = 266.4Ω .

Explanation of Solution

Given:

Operated power of plant is P=2.3MW

Voltage supply to the plant is ε=40kV

Frequency supply to the plant is F=60Hz

Resistance of the transmission line in R=5.2Ω

Phase δ = 25°

Formula used:

The relation between Z and δ are given as

  R=Zcosδ and XL=Zsinδ.......... (1)

Impedance in terms of Irms and εrms ,

  Z=εrmsIrms.......... (2)

Average power Pav=εrmsIrmscosδ.......... (3)

Calculation:

From equation (3) rms current can be rewritten as

  Irms=Pavεrmscosδ.......... (4)

Substitute the value Irms from equation (4) in equation (2)

  Z=ε2rmscosδPav.......... (5)

Substitute the values:

  Z=( 40kV)2cos25°2.3MW

= =630.3Ω

  R=630.3cos25°=571ΩXL=630.3Ωsin25°=266.4Ω

Conclusion:

Hence, theResistance R=571Ω and inductive impedance XL = 266.4Ω .

(b)

To determine

To Find:

RMS current and RMS voltage of the power line.

(b)

Expert Solution
Check Mark

Answer to Problem 18P

  63.4 A; 40.3kV

Explanation of Solution

Given:

Operated power of plant is P=2.3MW

Voltage supply to the plant is ε=40kV

Frequency supply to the plant is F=60Hz

Resistance of the transmission line in R=5.2Ω

Phase δ = 25°

Formula use:

RMS current

  Irms=Pavεrmscosδ.......... (1)

Calculation:

Substituting the values of Pav , εrms and δ in equation (1)

  Irms=2.3 MW40 kV cos 25°=63.4A

Apply Kirchhoff’s loop principle to the circuit:

  εrmsIrmsRIrmsZ=0

  εrms=Irms(R+Z).......... (2)

Substituting the value of Irms , R and Z in equation (2)

  εrms=63.4×(5.2+630.3)=40.3kV

Conclusion:

Hence,RMS current and RMS voltage are 63.4 A and 40.3kV .

(c)

To determine

To Find:

Amount of power lost in transmission.

(c)

Expert Solution
Check Mark

Answer to Problem 18P

  20.9kW

Explanation of Solution

Given:

Resistance of the transmission line in R=5.2Ω

Transmission current Irms = 63.4 A

Formula use:

Transmission power

  Ptrans=I2rmsR .......... (1)

Calculation:

Substituting the value of Irms , R in equation (1)

  Ptrans=I2rmsR = (63.4A) 2 ×5.2Ω=20.9kW

Conclusion:

Hence,the power loss in the transmission line is 20.9kW .

(d)

To determine

To Find:

The amount of money that would be saved by the electric utility during one month of operation.

(d)

Expert Solution
Check Mark

Answer to Problem 18P

$128

Explanation of Solution

Given:

Phase angle between voltage and current δ = 18°

Operated power of plant is P=2.3MW

Voltage supply to the plant is ε=40kV

Frequency supply to the plant is F=60Hz

Resistance of the transmission line in R=5.2Ω

Formula used:

Cost saving equation ΔC=(P25°P18°)Δt.......... (1)

Transmission power Ptrans=I2rmsR.......... (2)

RMS current Irms=Pavεrmscosδ.......... (3)

Calculation:

Substituting the value of Pav , εrms and δ in equation (3)

  Irms=2.3 MW40 kV cos18°=60.5A

Substituting the value of Irms , R in equation (2)

  Ptrans=I2rmsR = (60.5A) 2 ×5.2Ω=19kW

Cost saving is ΔC=(20.9kW19kW)(16h/d)(30d/month)($0.14kWh)

  =$128

Conclusion:

Hence, the cost is $128 .

(e)

To determine

To Find:

The amount ofcapacitance required to achieve the charge.

(e)

Expert Solution
Check Mark

Answer to Problem 18P

  33μF

Explanation of Solution

Given:

Phase angle between voltage and current δ = 18°

Operated power of plant is P=2.3MW

Voltage supply to the plant is ε=40kV

Frequency supply to the plant is F=60Hz

Resistance of the transmission line in R=5.2Ω

Saved cost per kilowatt-hour is $128.

Formula used:

Capacitance C=12πfXC .......... (1)

Relation between δ , XC , XL and R is

  tanδ=XLXCR.......... (2)

Conclusion:

From equation (2) XC can be rewritten as

  XC=XLRtanδ

Substituting the value of XL , R and δ in equation (1)

  C=16.28×60s 1×( 264.7571tan18°)=33μF

Conclusion:

Hence, the required capacitance is 33μF .

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
A transmission line whosecharacteristic impedance is 500,find that the speed of the wavetransmitted by this line is equal tothe speed of light in a vacuum, findboth the inductance per unit lengthand the amplitude per unit length ofthis line
An AC power generator produces 50. A (rms) at 3 600 V. Thevoltage is stepped up to 1.0 x 105 V by an ideal transformer,and the energy is transmitted through a long - distance powerline that has a resistance of 100. Ω. What percentage of thepower delivered by the generator is dissipated as heat in thepower line?
A large air conditioner has a resistance of 7.0 Ω and an inductive reactance of 15 Ω. If the air conditioner is powered by a 60.0-Hzgenerator with an rms voltage of 240 V, find (a) the impedance ofthe air conditioner, (b) its rms current, and (c) the average powerconsumed by the air conditioner

Chapter 29 Solutions

Physics For Scientists And Engineers

Knowledge Booster
Background pattern image
Physics
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, physics and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Glencoe Physics: Principles and Problems, Student...
Physics
ISBN:9780078807213
Author:Paul W. Zitzewitz
Publisher:Glencoe/McGraw-Hill
Text book image
Classical Dynamics of Particles and Systems
Physics
ISBN:9780534408961
Author:Stephen T. Thornton, Jerry B. Marion
Publisher:Cengage Learning
Text book image
Physics for Scientists and Engineers: Foundations...
Physics
ISBN:9781133939146
Author:Katz, Debora M.
Publisher:Cengage Learning
Text book image
University Physics Volume 2
Physics
ISBN:9781938168161
Author:OpenStax
Publisher:OpenStax
Introduction To Alternating Current; Author: Tutorials Point (India) Ltd;https://www.youtube.com/watch?v=0m142qAZZpE;License: Standard YouTube License, CC-BY