Chapter 29, Problem 3PP
Refer to transformer shown in Figure 29–14 and fill in the missing values.
Primary | Secondary | Load |
EP _______ | EP ________ | EP ________ |
IP ________ | IP _________ | IP ________ |
EL 13,800 V | EL 480 V | EL ________ |
IL ________ | IL _________ | IL ________ |
Ratio | Z = 2.5 Ω |
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
The copper loss of a certain transformer at full-load is 220W. Then the copper loss at half full-load will be__________________.
copper loss at half load
In transformer, the power will _________________________________ with decrease in voltage. be doubled remain same increases decreases
Belonging to a phase measured from a 220/48 V phase transformer, no-load (no load)
operation and short-circuit test.
values are given in the table below. Low voltage by applying rated voltage to the high
voltage (primary) winding.
voltage (secondary) winding ends were left unloaded and the results of the no-load
operation test were obtained. low voltage
By applying nominal current to the windings, the high voltage windings are short-circuited
and short-circuit test results are obtained.
has been done. In addition, the transformer with 5 V direct voltage applied to the high
voltage winding is 2.2 A direct current.
attracts. Calculate all equivalent circuit elements moved to the high voltage side.
Boşta çalışma testi
Gerilim
220 V
Güç
80 W
Akım
0,44 A
Kısa devre testi
Gerilim
12 V
Güç
Akım
65 W
16,1 A
Chapter 29 Solutions
DELMAR'S STANDARD TEXT OF ELECTRICITY
Ch. 29 - How many transformers are needed to make an...Ch. 29 - Two transformers rated at 100 kVA each are...Ch. 29 - How does the NEC specify that the high leg of a...Ch. 29 - An open-delta three-phase transformer system has...Ch. 29 - If a single-phase load is connected across the two...Ch. 29 - A three-phase transformer connection has a...Ch. 29 - A three-phase transformer connection has a...Ch. 29 - A three-phase transformer bank has the secondary...Ch. 29 - A three-phase transformer bank has the primary and...Ch. 29 - Referring to the transformer connection in...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Write in Briefly about circuit breaker, current transformer and voltage transformerarrow_forwardDETERMINE IF THE STATEMENT/IMAGE IS FOR : DELTA- DELTA or WYE- WYE (follow the writing and spelling as it is) Question: What is the connection of this transformer bank? Note: answer must be all caps with - in between XI | x2 | xoarrow_forwardRefer to the transformer shown in Figure 5-13 to answer the following questions. Assume that a voltage of 208 volts is applied across terminals B and E. How much voltage is across each of the following terminals? A–B ____ A–C ____ A–D ____ A–E ____ B–C ____ B–D ____B–E ____ C–D ____ C–E ____ D–E ____ 2.Assume a voltage of 120 volts is connected across terminals B and E, and that a load impedance of 20 V is connected across terminals A and C. What is the secondary and primary current? IP ____ IS ____ 3.What is the turns ratio of the winding between points B and E as compared to the winding between points D and E? 4.Assume that a voltage of 480 volts is connected across terminals A and E. What is the voltage across terminals C and D? 5.The transformer shown in Figure 5-13 is supplying 325-volt amperes to a load. The primary voltage is 240 volts. What is the primary current?arrow_forward
- In a typical unit substation the majority of the connections to ground are made in the_. A. High- voltage section B. Transformer section C. low- voltage section D. None of the above.arrow_forwardSeconday winding of transformer is made-up of __________________________ material. insulated copper conductor Cold Rolled Grain Oriented (CRGO) Silicon Steel insulated CRGO conductor Cold Rolled Grain Oriented (CRGO) conductorarrow_forwardh.1. In an alternating-current system, the maximum size for a copper grounding electrode conductor isA. 250 kcmil.B. 3/0.C. 500 kcmil.D. 4/0. h.2. The figure shows a fault condition in an ungrounded electrical system. Which of the following will occurbecause of the fault in this system?A. Only the overcurrent protector at Point A will trip open.B. The ground fault will heavily damage the service.C. Nothing will happen until a second ground fault occurs.D. The overcurrent protection will trip, shutting off all the line side power.arrow_forward
- - Transformers and Special Locations 7.a. Dry-type transformers are available in what configuration(s)?A. Single-phase or auto-phaseB. Poly-phase onlyC. Single- or poly-phaseD. Single-phase only7.b. How many separate and distinct electrical systems does an essential electrical system consist of?A. FiveB. ThreeC. FourD. Sixarrow_forwardFill in the blanks with a suitable describing for the following 1. Active component of no load current of transformer is _____________ 2. The resistance of series field windings is __________ and it's have ____________ number of turns 3. Leakage flux of transformer is ___________ 4. Starting torque is __________ in D.C. series motor 5. PID controller is _________arrow_forwardLOCAL 5652 UNION LABEL USW UNITED STEELWORKERS 6. Which one of the following types of construction is used for potential transformers? A. Window-type B. Wound-type C. Bushing-type D. Bar-typearrow_forward
- 18. If the current flowing in an operating circuit must be approximately measured without interrupting the current, which of the following through-type current transformers would you recommend? A. Bar-type B. Plain-through-type C.Split-core-type D. Bushing-typearrow_forwardA fault occurs at point F of the system in the figure. Calculate the sub-transient current in phase c of machine 1, assuming that the currents before the fault are zero. Both machines have a nominal capacity of 1200 kVA, 480 V, with reactances X”=X2= 11% and X0 = 3.5%. The nominal capacity of each three-phase transformer is 1200 kVA, 480 V Δ/ 2400 V and with reactances X1=X2=X0= 6%. Transmission line reactances are X1=X2=22% and X0 = 35% on a 1200 kVA, 2400 V basis. Neutral grounding reactor reactances are 8% on a kVA and kV basis. of the machines. a) Calculate the fault current if a ground fault occurs in phase a, b) The fault current if it is a line-to-line fault c) the voltage in phase b and c for the line-to-ground fault in phase a .arrow_forward2. Two different transformers details are tabulated below. Calculate the missed values in the table. Secondary terminal voltage of the second transformer is 487.5V when loaded. Determine the regulation of the transformer. N, | N2 V: 1 1 Transformer V, Flux Area L(60000 VA SOHZ) ? 100 100v ? ? 25cm 1.6KV II.(6000VA 50HZ 100 100 500 ? 0.04505Wb flux density 1.50T)arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON
Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,
Types of Protective Relays and Design Requirements, Part 1a.; Author: GeneralPAC: Power System Tutorials;https://www.youtube.com/watch?v=JYil4T5VSDM;License: Standard Youtube License