Question
Chapter 3, Problem 23Q
To determine
The reason for the tungsten to produce high intensity x-rays as compared to the molybdenum or chromium.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
For a given beam current and target thickness, why would you expect a tungsten target to produce a higher x-ray intensity than targets of molybdenum or chromium?
For an ion source, the maximum half-angle of ion emission from the source is 13 milliradians. The source is biased to 9 kV and the aperture radius is 2.5 mm. Assuming uniform emission of the aperture and uniform distribution of particles over this range, what is the normalized emmitance from the source if the beam consist of ions 40 Ar 9+?
During the deep X-ray therapy high energy X-rays are used. They are filtered by passing themthrough copper and aluminium plates. If the copper plate has thickness ?1 = 1 mm and aluminiumplate ?2 = 5 mm, find reduction in X-ray beam intensity. Linear attenuation coefficients for copperand aluminium are ?1 = 0,32 cm –1, and ?2 = 0,15 cm –1, respectively.
Chapter 3 Solutions
Modern Physics for Scientists and Engineers
Ch. 3 - Prob. 1QCh. 3 - Prob. 2QCh. 3 - Prob. 3QCh. 3 - Prob. 4QCh. 3 - Prob. 5QCh. 3 - Prob. 6QCh. 3 - Prob. 7QCh. 3 - Prob. 8QCh. 3 - Prob. 9QCh. 3 - In the experiment of Example 3.2, how could you...
Ch. 3 - Prob. 11QCh. 3 - Prob. 12QCh. 3 - Prob. 13QCh. 3 - Prob. 14QCh. 3 - Prob. 15QCh. 3 - Prob. 16QCh. 3 - Prob. 17QCh. 3 - Prob. 18QCh. 3 - Prob. 19QCh. 3 - Prob. 20QCh. 3 - Prob. 21QCh. 3 - Prob. 22QCh. 3 - Prob. 23QCh. 3 - Prob. 24QCh. 3 - Prob. 25QCh. 3 - Prob. 26QCh. 3 - Prob. 1PCh. 3 - Prob. 2PCh. 3 - Across what potential difference does an electron...Ch. 3 - Prob. 4PCh. 3 - Prob. 5PCh. 3 - Prob. 6PCh. 3 - Prob. 7PCh. 3 - Prob. 8PCh. 3 - Prob. 9PCh. 3 - Prob. 10PCh. 3 - Prob. 11PCh. 3 - Prob. 12PCh. 3 - Prob. 13PCh. 3 - Prob. 14PCh. 3 - Prob. 15PCh. 3 - Prob. 16PCh. 3 - Calculate max for blackbody radiation for (a)...Ch. 3 - Prob. 18PCh. 3 - Prob. 19PCh. 3 - Prob. 20PCh. 3 - White dwarf stars have been observed with a...Ch. 3 - Prob. 22PCh. 3 - Prob. 23PCh. 3 - Prob. 24PCh. 3 - Prob. 25PCh. 3 - Prob. 26PCh. 3 - Prob. 27PCh. 3 - Prob. 32PCh. 3 - Prob. 33PCh. 3 - Prob. 34PCh. 3 - Prob. 35PCh. 3 - Prob. 36PCh. 3 - Prob. 37PCh. 3 - Prob. 38PCh. 3 - Prob. 39PCh. 3 - Prob. 40PCh. 3 - Prob. 41PCh. 3 - Prob. 42PCh. 3 - Prob. 43PCh. 3 - Prob. 44PCh. 3 - Prob. 45PCh. 3 - Prob. 46PCh. 3 - Prob. 47PCh. 3 - Prob. 48PCh. 3 - Prob. 49PCh. 3 - Prob. 50PCh. 3 - Prob. 52PCh. 3 - Prob. 53PCh. 3 - Prob. 54PCh. 3 - Prob. 55PCh. 3 - Prob. 56PCh. 3 - Prob. 57PCh. 3 - Prob. 58PCh. 3 - Prob. 59PCh. 3 - Prob. 60PCh. 3 - Prob. 61PCh. 3 - Prob. 62PCh. 3 - Prob. 63PCh. 3 - Prob. 64PCh. 3 - Prob. 65PCh. 3 - Prob. 66PCh. 3 - Prob. 67PCh. 3 - Prob. 68PCh. 3 - The Fermi Gamma-ray Space Telescope, launched in...Ch. 3 - Prob. 70P
Knowledge Booster
Similar questions
- Typical 10-fold intensity reduction values for X-ray radiation with energy 1 MeV are 30 cm for bone tissues, 20 cm for aluminum, 5 cm for lead. Find mass and linear attenuation coefficients if densities are 1.85 g/cm3, 2.70 g/cm3, 11.35 g/cm3, respectively.arrow_forwardFind the minimum wavelength for x- ray with a) 35 kV and b) 45kV voltages.arrow_forwardDuring the deep X-ray therapy high energy X-rays are used. They are filtered by passing them through copper and aluminium plates. If the copper plate has thickness ?1 = 2 mm and aluminium plate ?2 =3 mm, find reduction in X-ray beam intensity. Linear attenuation coefficients for copper and aluminium are ?1 = 0.32 cm‐¹, and ?2 = 0.15 cm‐¹, respectively.arrow_forward
- The mean lifetime of the excited state produced by irradiating mercury vapor with a pulse of 263.7 nm radiation is 2.5 x10- 8s. Calculate the approximate value for the width of the fluorescence line produced in this way.arrow_forwardA point source emitting 2.1×1012 gamma-rays per second is located at the center of an ironsphere of radius 10 cm. The gamma-rays have an energy of 1.0 MeV. What is the uncollidedgamma-ray flux in cm-2-s-1 at a distance 20 cm from the source, assuming the sphere issurrounded by a vacuum?arrow_forwardTypical HVL values for X-ray radiation with energy 1 MeV are 3 cm for bone tissues, 2 cm for aluminum, 0.3 cm for lead. Find mass and linear attenuation coefficients if densities are 1.85 g/cm3 , 2.70 g/cm3 , 11.35 g/cm3, respectively.arrow_forward
- For the intensity of a monochromatic beam of gamma rays to be reduced to 30% of its initial value, what thickness of a material is needed if it is measured in terms of the half-value layer for that material?arrow_forwardWhat should be the minimum applied potential for complete stoppage of photocurrent in an experimental if the target material is copper and the incident frequency is 2.7x1015Hz.arrow_forwardHow many photons are contained in a beam of electromagnetic radiation of total power 180W if the source is (a) an AM radio station of 1100kHz (b) 8.0-nm x-rays and (c) 4.0-MeV gramma rays?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Modern PhysicsPhysicsISBN:9781111794378Author:Raymond A. Serway, Clement J. Moses, Curt A. MoyerPublisher:Cengage LearningUniversity Physics Volume 3PhysicsISBN:9781938168185Author:William Moebs, Jeff SannyPublisher:OpenStax
Modern Physics
Physics
ISBN:9781111794378
Author:Raymond A. Serway, Clement J. Moses, Curt A. Moyer
Publisher:Cengage Learning
University Physics Volume 3
Physics
ISBN:9781938168185
Author:William Moebs, Jeff Sanny
Publisher:OpenStax