Air is cooled from 80 F db and 67 F wb until it is saturated at 55 F. Using Chart 1a, find (a) the moisture removed per pound of dry air, (b) the heat removed to condense the moisture, (c) the sensible heat removed, and (d) the total amount of heat removed.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Inside a building, the temperature is −5°C, and the relative humidity is 31 percent. How much water vapor (in kg) is there in each cubic meter of air?
At 27°C and 1 ATP, a volume of air abruptly shrank by half. Temperature and pressure must be determined.
Saturated air at 55F dry bulb (db) temperature is heated to 100 F db. The required heating energy, in BTU/lbair, is most likely:
11 Btu/lbm
15 Btu/lb
9 Btu/lb
5 Btu/lb
20 Btu/lb
Chapter 3 Solutions
Heating Ventilating and Air Conditioning: Analysis and Design
Ch. 3 - A space is at a temperature of 75 F (24 C), and...Ch. 3 - Determine the humidity ratio, enthalpy, and...Ch. 3 - Suppose the air of Problem 3-2 is at a pressure...Ch. 3 - What is the enthalpy of moist air at 70 F (20 C)...Ch. 3 - The inside surface temperature of a window in a...Ch. 3 - What is the mass flow rate of dry air flowing at a...Ch. 3 - Determine the dew point of moist air at 80 F (27...Ch. 3 - A room is to be maintained at 72 F (22 C) db. It...Ch. 3 - Air is cooled from 80 F db and 67 F wb until it is...Ch. 3 - Conditions in a room are measured to be 80 F db...
Ch. 3 - The environmental conditions in a room are to be...Ch. 3 - Air enters a cooling coil at the rate of 5000 cfm...Ch. 3 - Air flowing in a duct has dry and wet bulb...Ch. 3 - Air is humidified with the dry bulb temperature...Ch. 3 - Air at 38 C db and 20 C wb is humidified...Ch. 3 - Two thousand cfm (1.0 m3/s) of air at an initial...Ch. 3 - Air at 40 F (5 C) db and 35 F (2 C) wb is mixed...Ch. 3 - Rework Problem 3-25, using Chart 1a, with the...Ch. 3 - The design cooling load for a zone in a building...Ch. 3 - Assume that the air in Problem 3-22 is supplied to...Ch. 3 - The sensible heat loss from a space is 500,000...Ch. 3 - Air enters a refrigeration coil at 90 Fdb and 75...Ch. 3 - A building has a total heating load of 200,000...Ch. 3 - Reconsider Problem 3-36 for an elevation of 5000...Ch. 3 - The system of Problem 3-34 has a supply air fan...Ch. 3 - An evaporative cooling system is to be used to...Ch. 3 - A cooling system is being designed for use at high...Ch. 3 - Consider a space heating system designed as shown...Ch. 3 - A variable-air-volume VAV cooling system is a type...Ch. 3 - Rework Problem 3-43 for an elevation of 5000 feet...Ch. 3 - The design condition for a space is 77 F (25 C) db...Ch. 3 - Rework Problem 3-45 for an elevation of 5000 feet...Ch. 3 - It is necessary to cool and dehumidify air from 80...Ch. 3 - Conditions in one zone of a dual-duct conditioning...Ch. 3 - Rework Problem 3-48 for an elevation of 5000 ft...Ch. 3 - A water coil in Problem 3-48 cools return air to...Ch. 3 - A multizone air handler provides air to several...Ch. 3 - Under normal operating conditions a zone has a...Ch. 3 - An interior zone of a large building is designed...Ch. 3 - Outdoor air is mixed with room return air to...Ch. 3 - Consider an enclosed swimming pool. The pool area...Ch. 3 - One particular zone served by a multizone air...Ch. 3 - A research building requires 100 percent outdoor...Ch. 3 - A space requires cooling in the amount of 120,000...
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
3.3 It is known that a vertical force of 200 lb is required to remove the nail at C from the board. As the nail...
Vector Mechanics for Engineers: Statics, 11th Edition
The moment of inertia Iy for the slender rod in terms of the rod’s total mass m .
Engineering Mechanics: Statics & Dynamics (14th Edition)
Comprehension Check 7-14
The power absorbed by a resistor can be given by P = I2R, where P is power in units of...
Thinking Like an Engineer: An Active Learning Approach (3rd Edition)
5.1 through 5.9
Locate the centroid of the plane area shown.
Fig. P5.1
Vector Mechanics for Engineers: Statics and Dynamics
Assume the following vectors are already defined: V1=[302]V2=[214]V3=[5131]V4=[0.50.10.20.2] For each of the fo...
Thinking Like an Engineer: An Active Learning Approach (4th Edition)
Locate the centroid of the area. Prob. 9-17
Engineering Mechanics: Statics
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A rigid tank contains saturated liquid - vapor water at 85oC. If the quality of the mixture is 50%, the enthalpy, in kJ/kg, is most likely: 1389 2295 1504 356arrow_forwardThe change in enthalpy is, in kJ/kg, (a) 30 (b) 70 (c) 100 (d) insufficient information to determinearrow_forwardA vessel of volume 1 m3 initially contains one percent by volume saturated liquid water and the rest saturated vapour at 1 bar. How much heat is to be supplied so that the vessel gets filled with vapour? Take data from steam tables. Answer= 195,814 Jarrow_forward
- Calculate the energy requirement to raise the temperature of 1 kg of water from 60 ° C of water to 90 ° C using the following approach; a. Average specific heat usage (Tab A Singh's Book. 4.1) = kJ b. The enthalpy change in the water - vapor saturation table (Tab A Singh's Book. 4.2) = kJarrow_forward1 pound mass of steam expands isentropically from 300psia and 600°F to atmosphere 14.696 psia. Use the Mollier chart to determine the final enthalpy and moisture pertantage Please show me how to calculate using Mollier chart. Please use the chart....arrow_forwardObtain the value of Ufg at 250C, in kj/kg, directly from the steam tables. Ufg = ? kj/kgarrow_forward
- 14. 6.3 kg/s of oxygen undergoes a steady flow process. At inlet state, the reduced pressure is 2 and reduced temperature is 1.3. At the exit state, the reduced pressure is 3 and the reduced temperature is 1.7. Using the generalized compressibility and correction charts, what is the rate of change of total enthalpy for this process? Use co -0.913 kJ/kg K. Express your answer in kW.arrow_forwardwhat is true of the heat content for a system at constant pressurearrow_forwardNeed help with these two homework problems 1) A tank contains a two-phase liquid–vapor mixture of Refrigerant 22 at 8 bar. The mass of saturated liquid in the tank is 25 kg and the quality is 30%. Determine the volume of the tank, in m3, and the percentage of the total volume occupied by saturated vapor. 2) One kilogram of water contained in a piston–cylinder assembly, initially saturated vapor at 100 kPa, is condensed at constant pressure to saturated liquid. Consider an enlarged system consisting of the water and enough of the nearby surroundings that heat transfer occurs only at the ambient temperature of 25oC. Assume the state of the nearby surroundings does not change during the process, and ignore kinetic and potential energy effects. For the enlarged system, determine the heat transfer, in kJ, and the entropy production, in kJ/K.arrow_forward
- Calculate the energy requirement to raise the temperature of 1 kg of water from 30 ° C of water to 100 ° C using the following approach; a. Average specific heat usage (Tab A Singh's Book 4.1) = Answer kJ. b. Enthalpy change in water-vapor saturation table (Singh's Book Tab A. 4.2) = Answer kJ.arrow_forwardSaturated vapor R134a flows through a channel with a volumetric flow rate of 145 m3/min at a pressure of 12 bar. Determine the mass flow rate of the R134a in kg/s.arrow_forwardAt P = 1.8 and h = 3040 Kj/kg. Determine the Temperature, Internal Energy, Volume with the use of steam tables.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
First Law of Thermodynamics, Basic Introduction - Internal Energy, Heat and Work - Chemistry; Author: The Organic Chemistry Tutor;https://www.youtube.com/watch?v=NyOYW07-L5g;License: Standard youtube license