Chapter 3, Problem 3.2.5P
To determine
(a)
If the member has enough strength using Load and Resistance Factor Design (LRFD).
To determine
(b)
If the member has enough strength.
Expert Solution & Answer
![Check Mark](/static/check-mark.png)
Trending nowThis is a popular solution!
![Blurred answer](/static/blurred-answer.jpg)
Students have asked these similar questions
The tension member is a PL 1⁄2 × 6. It is connected to a 3⁄8-inch-thick gusset plate with 7⁄8-inch-diameter bolts. Both components are of A242 steel.
Note:
A242 Fu = 70ksi
dh = db + 1/16’’
Use: Consider deformation at the bolt hole
what is the:
minimum spacing as per AISC code provisions
maximum spacing as per AISC code provisions
minimum edge distance as per AISC code provisions
maximum edge distance as per AISC code provisions
A 15" x 3/8" bar of A572 Gr. 50 steel is used as a tension member. It is connected to a gusset plate with 7/8-in diameter bolts as shown in the figure. Use s = 2.0 and g = 3.0.a) Determine the design tensile strength of the section based on yielding of the gross area.b) Determine the critical net area of the connection shown.
A 15" x 3/8" bar of A572 Gr. 50 steel is used as a tension member. It is connected to a gusset plate with 7/8-in diameter bolts as shown in the figure. Use s = 2.0 and g = 3.0.
Determine the critical net area of the connection shown.
Determine the design tensile strength of the section based on yielding of the gross area.
Chapter 3 Solutions
Bundle: Steel Design, Loose-leaf Version, 6th + Mindtap Engineering, 1 Term (6 Months) Printed Access Card
Ch. 3 - Prob. 3.2.1PCh. 3 - Prob. 3.2.2PCh. 3 - Prob. 3.2.3PCh. 3 - Prob. 3.2.4PCh. 3 - Prob. 3.2.5PCh. 3 - Prob. 3.2.6PCh. 3 - Prob. 3.3.1PCh. 3 - Prob. 3.3.2PCh. 3 - Prob. 3.3.3PCh. 3 - Prob. 3.3.4P
Ch. 3 - Prob. 3.3.5PCh. 3 - Prob. 3.3.6PCh. 3 - Prob. 3.3.7PCh. 3 - Prob. 3.3.8PCh. 3 - Prob. 3.4.1PCh. 3 - Prob. 3.4.2PCh. 3 - Prob. 3.4.3PCh. 3 - Prob. 3.4.4PCh. 3 - Prob. 3.4.5PCh. 3 - Prob. 3.4.6PCh. 3 - Prob. 3.5.1PCh. 3 - Prob. 3.5.2PCh. 3 - Prob. 3.5.3PCh. 3 - Prob. 3.5.4PCh. 3 - Prob. 3.6.1PCh. 3 - Prob. 3.6.2PCh. 3 - Prob. 3.6.3PCh. 3 - Select an American Standard Channel shape for the...Ch. 3 - Prob. 3.6.5PCh. 3 - Use load and resistance factor design and select a...Ch. 3 - Select a threaded rod to resist a service dead...Ch. 3 - Prob. 3.7.2PCh. 3 - Prob. 3.7.3PCh. 3 - Prob. 3.7.4PCh. 3 - Prob. 3.7.5PCh. 3 - Prob. 3.7.6PCh. 3 - Prob. 3.8.1PCh. 3 - Prob. 3.8.2PCh. 3 - Prob. 3.8.3PCh. 3 - Prob. 3.8.4PCh. 3 - Prob. 3.8.5P
Knowledge Booster
Similar questions
- Two plates each with thickness t = 16 mm are bolted together with 6 – 22 mm diameter bolts forming a lap connection. Bolt spacing are as follows: S1 = 40 mm, S2 = 80 mm, S3 = 100 mm. Bolt hole diameter = 25 mm. Using A36 steel having Fy = 248 MPa and Fu = 400 MPa. P P S - P S2 S2 DETERMINE: 1. Determine the allowable load Pa based on bearing at bolt holes. (ASD) 2. Determine the ultimate load Pu based on block shear.arrow_forwardA 16 mm thick tension member is connected by two 6.25 mm spliced plates as shown. The tension member carries a service loads of dead load of 110 kN and a live load of 100 kN. 40, 80 , 40 , 40, 80 40 1625 mm 16 mm 1625 mm Fy 248 MPa Fu = 400 MPa Diam. of bolts = 16 mm Fnv = 300 MPa O Determine the nominal strength for one bolt due to shear. O Determine the nominal strength for one bolt due to bearing strength of the connection. ® Determine the number of bolts required for the connection.arrow_forwardThe tension member is a PL 12 x 6. It is connected to a 38-inch-thick gusset plate with 7/8-inch-diameter bolts. Both components are of A242 steel. Note: A242 Fu = 70ksi dh = db + 1/16" Use: Consider deformation at the bolt hole 3" PL ... PL ½x 6 12" 24" 24" 12" a. What is the minimum spacing as per AISC code provisions Round your answer to 3 decimal places.arrow_forward
- A double-angle shape is shown in the figure. The steel is A36, and the holes are for 2-inch-diameter bolts. Assume that A₂ = 0.75An. Ae 1 2 Determine the design tensile strength for LRFD. Determine the allowable strength for ASD. CIVIL ENGINEERING - STEEL DESIGN AL Section 2L5 x 3 x 516 LLBBarrow_forwardA C8 × 11.5 is connected to a gusset plate with 7⁄8-inch-diameter bolts as shown in the Figure . The steel is A572 Grade 50. If the member is subjected to dead load and live load only, what is the total service load capacity if the live-to-dead load ratio is 3? Assume that Ae = 0.85An.a. Use LRFD.b. Use ASD.arrow_forwardPROBLEM NO. 2: Two plates each with thickness t = 16mm are bolted together with 6-22mm diameter bolts forming a lap connection. Bolt Spacing are as follows: S₁ = 40mm, S₂ = 80mm, S3 = 100mm. Bolt diameter = 22mm. Use A36 steel. Calculate the allowable strength due to block shear only. I= 16 mm S₁ S₂ S₂ S1 40 80 80 40 18-16mm S-40 S₁-100 S-40arrow_forward
- The tension member is a PL 1⁄2 × 6. It is connected to a 3⁄8-inch-thick gusset plate with 7⁄8-inch-diameter bolts. Both components are of A242 steel. Note: A242 Fu = 70ksi dh = db + 1/16’’ Use: Consider deformation at the bolt holearrow_forwardA bracket cut from a W310X179 is connected to a W310X179 column flange with 12 A325 bearing-type bolts as shown in the figure. A 50 steel is used. The line of action of the load passes through the center of gravity of the connection. What size bolt is required? a. Use LRFD. b. Use ASD. D = 55k L = 145k I'-1" CS Scanned with CamScanner 22" 5 sp @ 4" てarrow_forwardThe splice plates shown in Figure 2 are 1/2-inch-thick. How many 7/8-inch-diameter, Group B bolts are required? The given load consists of 30% dead load and 70% live load. A36 steel is used. Threads are not excluded from the shear plane. 90 k Figure 2 a. Use LRFD. b. Use ASD. % in. 90 karrow_forward
- The tension member shown in Figure 3.4-2 is a PL 5/8 x 10, and the steel is A36. The bolts are 7/8-inch in diameter. a. Determine the design strength for LRFD. b. Determine the allowable strength for ASD. | 2" +|+| in seinefrinehich 9 оо SOarrow_forwardThe tension member shown is an angle L150 x 90 x 10, of A36 steel, with Fy= 250 MPa and Fu= 400 MPa, and is subjected to a service DL= 150 KN and a service LL= 150 KN The bolts are 20 mm o. Use ASD. 40mm 40mn 40mm 50mm ... Compute the allowable strength based on yielding in KN.0 Compute the nominal strength based on fracture in KN.0 Check the adequacy of the section.0arrow_forwardA structural tee bracket is attached to a column flange with six bolts as shown in Figure . All structural steel is A992. Check this connection for compliance with the AISC Specification. Assume that the bearing strength is controlled by the bearing deformation strength of 2.4dtFu. a. Use LRFD. b. Use ASD.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Steel Design (Activate Learning with these NEW ti...Civil EngineeringISBN:9781337094740Author:Segui, William T.Publisher:Cengage Learning
![Text book image](https://www.bartleby.com/isbn_cover_images/9781337094740/9781337094740_smallCoverImage.gif)
Steel Design (Activate Learning with these NEW ti...
Civil Engineering
ISBN:9781337094740
Author:Segui, William T.
Publisher:Cengage Learning