Earth Is the Lords
5th Edition
ISBN: 9781121660069
Author: Caldwell, Taylor
Publisher: MCG/CREATE
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 3, Problem 3.4P
A three-phase, Y-connected, four-pole winding is installed in 24 slots on a stator. There are 40 turns of wire in each slot of the windings. All coils in each phase are connected in series. The flux per pole in the machine is 0.060 Wb, and the speed of rotation of the magnetic field is 1800 r/min.
- What is the frequency of the voltage produced in this winding?
- What are the resulting phase and terminal voltages of this stator?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A three-phase Δ-connected six-pole winding is installed in 36 slots on a stator. There are 150 turns of
wire in each slot of the windings. All coils in each phase are connected in series. The flux per pole in the
machine is 0.060 Wb, and the speed of rotation of the magnetic field is 1000 r/min.
(a) What is the frequency of the voltage produced in this winding?
(b) What are the resulting phase and terminal voltages of this stator?
A three-phase Y-connected four-pole winding is installed in 24 slots on a stator. There are 40 turns of
wire in each slot of the windings. All coils in each phase are connected in series. The flux per pole in the
machine is 0.060 Wb, and the speed of rotation of the magnetic field is 1800 r/min.
(a) What is the frequency of the voltage produced in this winding?
(b) What are the resulting phase and terminal voltages of this stator
AC Machinery Fundamentals
A three-phase delta-connected six-pole winding is installed in 36 slots on a stator. There are 150 turns of wire in each slot of the windings. All coils in each phase are connected in series. The flux per pole in the machine is 0.060 Wb, and the speed of rotation of the magnetic field is 1000 r/min. What are the resulting phase and terminal voltages?
Chapter 3 Solutions
Earth Is the Lords
Ch. 3 - What is the principal difference between a...Ch. 3 - Prob. 3.2QCh. 3 - Prob. 3.3QCh. 3 - What is the equation for the induced torque in an...Ch. 3 - The simple loop rotating in a uniform magnetic...Ch. 3 - Prob. 3.2PCh. 3 - The first ac power system in the United States ran...Ch. 3 - A three-phase, Y-connected, four-pole winding is...Ch. 3 - A three-phase, -connected, six-pole winding is...Ch. 3 - A three-phase, Y-connected, 60 Hz, two-pole...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A 6-pole, dc machine has a double layer, lap winding in 63 slots. The coils in the machine have one turn each. There are 189 commutator bars. The flux per pole is 0.082 Wb. The rotor speed is 700 rev/min. a. Find the number of coils per slot. b. Find the number of conductors per slot. c. Is full-pitch winding possible? Why? d. Find the number for the bottom-layer conductor of coil 1. e. We can decide to use equalizers on this machine. Why? f. It is possible to use 21 equalizers on this machine. Why? h. Find the commutator bar(s) to be connected with the commutator bar 1 to an equalizer. i. Find the commutator bar(s) that must be connected to equalizer number 5 if 21 equalizers are used and commutator bar 1 is connected to equalizer number 1. g. Find the dc voltage that is generated in this machine.arrow_forwardA 6-pole, dc machine has a double layer, lap winding in 63 slots. The coils in the machine have one turn each. There are 189 commutator bars. The flux per pole is 0.082 Wb. The rotor speed is 700 rev/min. A. Find the number of coils per slot. B. Find the number of conductors per slot. C. Is full-pitch winding possible? Why? D. Find the number for the bottom-layer conductor of coil 1. We can decide to use equalizers on this machine. Why? E. It is possible to use 21 equalizers on this machine. Why?arrow_forward5-5.When one coil of a magnetically coupled pair has a current 5.0 A the resulting fluxes ?11and ?12 are 0.2mWb and 0.4mWb, respectively. If the turns are N1= 500 and N2=1500, find L1, L2, M, and the coefficient of coupling karrow_forward
- Which one of the following is not the function of pole shoes in a dc machine? (1) To reduce eddy current loss (2)To support the field coils (3)To spread out flux for better uniformity (4)To reduce the reluctance of the magnetic path (5)None of the above.arrow_forwardA 4 pole dc generator runs at 750 rpm and generates an emf of 240 V. The armature is wave wound and has 792 conductors. If the total flux from each pole is 0.0145 Wb, If leakage coefficient is given as the ratio of the total flux/pole to the working flux per pole, find its value.arrow_forwardAC Machinery Fundamental 1.The simple loop is rotating in a uniform magnetic field shown in the figure has the following characteristics. Calculate the voltage induced in this rotating loop. 2.What is the frequency of the voltage produced in this loop? 3.Suppose that a 10-ohm resistor is connected as a load across the terminals of the loop. Calculate the current that would flow through the resistor. 4.Calculate the magnitude and direction of the induced torque on the loop for the conditions in (c). 5.Calculate the instantaneous and average electric power being generated by the loop for the conditions in problem (c). 6.Calculate the mechanical power being consumed by the loop for conditions in (c)arrow_forward
- A 6-pole, 3-phase AC generator has 12 slots per pole and four conductors per slots. The winding is 5/6 pitch. There are 2508000 maxwells entering the armature from each north pole, this flux is sinusoidally distributed along the air gap. The armature coils are all connected in series. The winding is wye-connected. Determine the phase and line voltage if the machine is affected by 2nd, 3rd and 5th harmonics.arrow_forwardConsider the magnetic circuit shown in Figure T14.4. The core has a relative permeability of 1500. a. Carefully estimate the flux density in the air gap. b. Determine the inductance of the coil.arrow_forwardCalculate the torque developed by the armature of a 4 pole lap wound, dc machine having 728 active conductors and running at 1800rpm. The flux per pole is 30mWb and the armature is designed to carry a maximum line current of 100A. 347.7 N-m 48.2 N-m 72.4 N-m 26.4 N-marrow_forward
- 1- The armature of a 2-pole, 200V generator has 400 conductors and runs at 300 r.p.m. Calculate the useful flux per pole. If the number of turns in each field coil is 1200, what is the average value of the electromotive force induced in each coil on breaking the field if the flux dies away completely in 0.1 sec?arrow_forwardA 4 pole armature of a DC machine has 175 conductors and a flux per pole of 0.1 wb. Find the EMF generated when running at 600 rpm, when the armature is Lap wound.arrow_forwardA dc machine has 4-pole, wave wound armature with 46 slots and 16 conductors per slot. If induced voltage in the armature is 480 V at 1,200 rpm, determine the flux per polearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
Magnets and Magnetic Fields; Author: Professor Dave explains;https://www.youtube.com/watch?v=IgtIdttfGVw;License: Standard YouTube License, CC-BY