Chapter 3, Problem 3.5QAP
Interpretation Introduction
Interpretation:
The output voltage
An explanation is also required as why the given circuit works as a voltage follower with gain.
Concept introduction:
The concept of virtual ground(short) is used based on which the voltage maintained at both the terminals is the same. From the given circuit the relation between the input and output voltage can be obtained using virtual short and potential divider concept. The output can then be proved observed to follow the input with a gain.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Design a voltage divider biased common emitter amplifier with a bypassed emitter resistance for a DC
supply of Vcc D (18+R)V and a quiescent current of 2mA. The voltage drop across collector should be
40% of DC supply voltage For the given design conditions: R = 02
Compute the circuit resistances.biased values of voltages and currents.
Draw the completely labelled circuit diagram.
2
5. The magnetic flux through one turn of a 55-turn coil of wire is reduced from 29 Wb to 5.0 Wb in
0.80 s, which results in an induced current of 36000 mA. What is the total resistance of the wire
in the coil.
Chapter 3 Solutions
Principles of Instrumental Analysis
Ch. 3 - Prob. 3.1QAPCh. 3 - Prob. 3.2QAPCh. 3 - Prob. 3.3QAPCh. 3 - Prob. 3.4QAPCh. 3 - Prob. 3.5QAPCh. 3 - Prob. 3.6QAPCh. 3 - Prob. 3.7QAPCh. 3 - Prob. 3.8QAPCh. 3 - Prob. 3.9QAPCh. 3 - Prob. 3.10QAP
Ch. 3 - Prob. 3.11QAPCh. 3 - Prob. 3.12QAPCh. 3 - Prob. 3.13QAPCh. 3 - Prob. 3.14QAPCh. 3 - Prob. 3.15QAPCh. 3 - Prob. 3.16QAPCh. 3 - Prob. 3.17QAPCh. 3 - Prob. 3.18QAPCh. 3 - Prob. 3.19QAPCh. 3 - Prob. 3.20QAPCh. 3 - Prob. 3.21QAPCh. 3 - Prob. 3.22QAPCh. 3 - Prob. 3.23QAPCh. 3 - Prob. 3.24QAPCh. 3 - Prob. 3.25QAP
Knowledge Booster
Similar questions
- The transmittance of a solution in 1-cm cuvette is 50.0%. Calculate the transmittance of the same solution in 0.5-cm cuvette.arrow_forwardCalculate non-standard Ecell 2+ 2+ (ac) + Zn cac) [Zn²+] = 0.023 M 3+ Co Cae) + Zn (s) = Co [Co³+] = 0.25M [co²+] = 0.04M Ered (Zn) = -0.763v Ered (Co) = 1.842Varrow_forward1. A compound has a molar absorptivity of 3.031 x 10° L cm1 mol1. If a 15.00 mm-length cell is used to hold the sample, and a transmittance of 19.53 % is measured, what is the molarity of the compound in solution?arrow_forward
- The table shows a series of standard additions of Cu(II)to acidified tap water samples measured by anodic stripping voltammetry at a platinum electrode. The unknown and all standard additions were made up to the same final volume. 1. Plot absorbance as a function of the concentration of Cu (II) standard. Determine the equation of the line and the X intercept. Find the concentration of Cu(II) in the water.arrow_forwardThe molar absorptivity for aqueous solutions of phenol at 211 nm is 6.17 × 103 L cm-1 mol-1. Calculate the permissible range of phenol concentrations if the transmittance is to be less than 85% and greater than 7% when the measurements are made in 1.00-cm cells.arrow_forwardDescribe the difference between power-compensated, heat-flux, and modulated DSC instruments.arrow_forward
- A 2993.72 m/z ion is accelerated into the 1.85 m flight tube of a linear time-of-flight mass spectrometer with an accelerating voltage of 10.0 kV. How long will it take the ion to drift through the flight tube and reach the detector? t =arrow_forwardA solution containing 8.75 ppm KMnO4 has a transmittance of 0.743 in a 1.00 cm cell at 520 nm. Calculate the molar absorptivity of KMnO4.arrow_forwardThe molar absorptivity for aqueous solutions of phenol at 211 nm is 6.17 x 103 L cml mol-'. Calculate the permissible range of phenol concentrations if the transmittance is to be less than 85% and greater than 7% when the measurements are made in 1.00-cm cells.arrow_forward
- number 20, is this correct?arrow_forwardSolve this problem pleasearrow_forwardYou are given two containers, one with 3.00 mg Mn 2+ and one with an unknown amount of Mn 2+ .You oxidize the Mn 2+ to the purple permanganate ion (MnO 4 - ) and dilute the solutions to 250.0 mLs.The solution containing the 3.00 mg Mn is used to prepare a third solution containing 1.50 mg Mn.The transmittances of the solutions are measured at 530 nm using a dilapidated Spectronic 20. Fromthe data below, calculate the amount of Mn in the unknown. For a linear curve, consider y=kx+b Mn (mg) %T3.00 30.81.50 55.2Unknown 37.4arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningChemistry for Engineering StudentsChemistryISBN:9781285199023Author:Lawrence S. Brown, Tom HolmePublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Chemistry for Engineering Students
Chemistry
ISBN:9781285199023
Author:Lawrence S. Brown, Tom Holme
Publisher:Cengage Learning