POWER SYSTEM ANALYSIS+DESIGN-EBK >I<
6th Edition
ISBN: 9781337259170
Author: Glover
Publisher: INTER CENG
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 3, Problem 3.7MCQ
Consider Figure 3.5. Match the following, those on the left to those on the right.
(i)
(a) Exciting current
(ii)
(b) Magnetizing Current
(iii)
(c) core loss current
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
(9) The hysteresis losses in electrical machines reduced.
a- By core lamination.
b- By core isolation.
c- By choosing another type of iron.
(10) The eddy current losses in electrical machines reduced.
d- By core lamination.
e- By core isolation.
f- By choosing another type of iron.
Please choose the correct answer and explain if possible. Thank you.
4. The main terminal voltage across an ON conducting SCR depends on the instantaneous main terminal current in the following way:
a. They are proportional
b. The voltage increases as the current increases, but no quite proportionally
c. The voltage increases as the current increases, by a squared (seond power) relationship
d. They are virtually non-related
5. To turn Off a conducting SCR in a dc-powered circuit, it is necessary to:
a. Interrupt (stop) the gate current
b. Wait for the main terminal current to fall below IHO when the supply voltage crosses through zero
c. Deliver a pulse of negative gate current via the gate lead
d. Place a temporary reverse bias across the SCR’s main terminals
6. In a simple RC charging circuit used for trigger-control of an SCR, a good range of adjustment of the RC time-constant is:
a. 1 to 5 msec
b. 1 to 30 msec
c. 0.1 to 10 msec
d. 2 to 25 μsec
Q5. For the following center tapped transformer, show the waveform across each half of
the secondary winding and across Ri, when a 100 V peak sine wave is applied to the
primarywinding. What is the PIV rating must the diode have?
(Use constant voltage drop model for the Silicon diode)
D1
IN4001
R.
V out
OV
10 kN
D2
IN4001
llle
Chapter 3 Solutions
POWER SYSTEM ANALYSIS+DESIGN-EBK >I<
Ch. 3 - The Ohms law for the magnetic circuit states that...Ch. 3 - For an ideal transformer, the efficiency is (a) 0...Ch. 3 - For an ideal 2-winding transformer, the...Ch. 3 - An ideal transformer has no real or reactive power...Ch. 3 - For an ideal 2-winding transformer, an impedance...Ch. 3 - Consider Figure 3.4. For an ideal phase-shifting...Ch. 3 - Consider Figure 3.5. Match the following, those on...Ch. 3 - The units of admittance, conductance, and...Ch. 3 - Match the following: (i) Hysteresis loss (a) Can...Ch. 3 - For large power transformers rated more than 500...
Ch. 3 - For a short-circuit test on a 2-winding...Ch. 3 - The per-unit quantity is always dimensionless. (a)...Ch. 3 - Consider the adopted per-unit system for the...Ch. 3 - The ideal transformer windings are eliminated from...Ch. 3 - To convert a per-unit impedance from old to new...Ch. 3 - In developing per-unit circuits of systems such as...Ch. 3 - Prob. 3.17MCQCh. 3 - Prob. 3.18MCQCh. 3 - With the American Standard notation, in either a...Ch. 3 - Prob. 3.20MCQCh. 3 - In order to avoid difficulties with third-harmonic...Ch. 3 - Does an open connection permit balanced...Ch. 3 - Does an open- operation, the kVA rating compared...Ch. 3 - It is stated that (i) balanced three-phase...Ch. 3 - In developing per-unit equivalent circuits for...Ch. 3 - In per-unit equivalent circuits of practical...Ch. 3 - Prob. 3.27MCQCh. 3 - Prob. 3.28MCQCh. 3 - For developing per-unit equivalent circuits of...Ch. 3 - Prob. 3.30MCQCh. 3 - Prob. 3.31MCQCh. 3 - Prob. 3.32MCQCh. 3 - The direct electrical connection of the windings...Ch. 3 - Consider Figure 3.25 of the text for a transformer...Ch. 3 - (a) An ideal single-phase two-winding transformer...Ch. 3 - An ideal transformer with N1=1000andN2=250 is...Ch. 3 - Consider an ideal transformer with...Ch. 3 - A single-phase 100-kVA,2400/240-volt,60-Hz...Ch. 3 - Prob. 3.5PCh. 3 - Prob. 3.6PCh. 3 - Consider a source of voltage v(t)=102sin(2t)V,...Ch. 3 - Prob. 3.8PCh. 3 - Prob. 3.9PCh. 3 - A single-phase step-down transformer is rated...Ch. 3 - For the transformer in Problem 3.10. The...Ch. 3 - Prob. 3.12PCh. 3 - A single-phase 50-kVA,2400/240-volt,60-Hz...Ch. 3 - A single-phase 50-kVA,2400/240-volt,60-Hz...Ch. 3 - Rework Problem 3.14 if the transformer is...Ch. 3 - A single-phase, 50-kVA,2400/240-V,60-Hz...Ch. 3 - The transformer of Problem 3.16 is supplying a...Ch. 3 - Using the transformer ratings as base quantities,...Ch. 3 - Using the transformer ratings as base quantities....Ch. 3 - Using base values of 20 kVA and 115 volts in zone...Ch. 3 - Prob. 3.21PCh. 3 - A balanced Y-connected voltage source with...Ch. 3 - Figure 3.32 shows the oneline diagram of a...Ch. 3 - For Problem 3.18, the motor operates at full load,...Ch. 3 - Consider a single-phase electric system shown in...Ch. 3 - A bank of three single-phase transformers, each...Ch. 3 - A three-phase transformer is rated...Ch. 3 - For the system shown in Figure 3.34. draw an...Ch. 3 - Consider three ideal single-phase transformers...Ch. 3 - Reconsider Problem 3.29. If Va,VbandVc are a...Ch. 3 - Prob. 3.31PCh. 3 - Determine the positive- and negative-sequence...Ch. 3 - Consider the three single-phase two-winding...Ch. 3 - Three single-phase, two-winding transformers, each...Ch. 3 - Consider a bank of this single-phase two-winding...Ch. 3 - Three single-phase two-winding transformers, each...Ch. 3 - Three single-phase two-winding transformers, each...Ch. 3 - Consider a three-phase generator rated...Ch. 3 - The leakage reactance of a three-phase,...Ch. 3 - Prob. 3.40PCh. 3 - Consider the single-line diagram of the power...Ch. 3 - For the power system in Problem 3.41, the...Ch. 3 - Three single-phase transformers, each rated...Ch. 3 - A 130-MVA,13.2-kV three-phase generator, which has...Ch. 3 - Figure 3.39 shows a oneline diagram of a system in...Ch. 3 - The motors M1andM2 of Problem 3.45 have inputs of...Ch. 3 - Consider the oneline diagram shown in Figure 3.40....Ch. 3 - With the same transformer banks as in Problem...Ch. 3 - Consider the single-Line diagram of a power system...Ch. 3 - A single-phase three-winding transformer has the...Ch. 3 - The ratings of a three-phase three-winding...Ch. 3 - Prob. 3.52PCh. 3 - The ratings of a three-phase, three-winding...Ch. 3 - An infinite bus, which is a constant voltage...Ch. 3 - A single-phase l0-kVA,2300/230-volt,60-Hz...Ch. 3 - Three single-phase two-winding transformers, each...Ch. 3 - A two-winding single-phase transformer rated...Ch. 3 - A single-phase two-winding transformer rated...Ch. 3 - Prob. 3.59PCh. 3 - PowerWorid Simulator case Problem 3_60 duplicates...Ch. 3 - Rework Example 3.12 for a+10 tap, providing a 10...Ch. 3 - A 23/230-kV step-up transformer feeds a...Ch. 3 - The per-unit equivalent circuit of two...Ch. 3 - Reconsider Problem 3.64 with the change that now...Ch. 3 - What are the advantages of correctly specifying a...Ch. 3 - Why is it important to reduce the moisture within...Ch. 3 - What should be the focus of transformer preventive...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- In developing per-unit circuits of systems such as the one shown in Figure 3.10. when moving across a transformer, the voltage base is changed in proportion to the transformer voltage ratings. (a) True (b) Falsearrow_forwardThe number of disc insulators used in a suspension insulator setup with string efficiency 80 %, phase voltage 33 kV, and the voltage across insulator nearest to conductor 11 kV is .......................... Complete the answer.arrow_forwardThe core of a transformer operating at 50 Hz has an eddy current loss of 100 W/m3 and the corelaminations have a thickness of 0.50 mm. The core is redesigned so as to operate with the same eddycurrent loss but at a different voltage and at a frequency of 250 Hz. Assuming that at the new voltage themaximum flux density is one-third of its original value and the resistivity of the core remains unaltered,determine the necessary new thickness of the laminations. Clear and detailed solution.arrow_forward
- Full calculation with any assumption needed. All sub questions please as it is all related.arrow_forwardP2-Draw the equivalent circuit of a single-phase transformer and explain how the core losses are almost invariant to the load (current). How do they depend on the terminal voltages of the transformer? Also, using the equivalent circuit explain how the copper losses depend on the load current.arrow_forwardComplete the table below using the attached circuit. Note: -When computing in half wave rectifier "J1 is ON".arrow_forward
- YVTA io YVIA Q1) Fill in the blanks by inserting appropriate words/numbers 1- The high value of efficiency in voltage distribution over suspension insulator string is because of ... .... a) grading the insulators. b) using short cross-arms. c) using a guard ring. d) using longer cross-arms. 2- The per unit value of the transformer in the figure below is ... . assume the Spase is 50 MVA and Vese 20 kV in generator side. 50 0.3 P.u 0.2 p.u 20 MVA 20 MVA 25 KV 25 /33KV 3- During the critical disruptive voltage .. a) the conductors are surrounded by a faint violet glow. b) appearing of high hissing noise c) high power losses may happened d) none of the all above 4- If each of the power system component is represented by its equivalent circuit in a diagram, then this diagram is called .......... a) single line diagram b) impedance diagram c) reactance diagram d) power flow diagram. 8.arrow_forwardDifference between sc and oc test in transformer...arrow_forward2arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
TRANSFORMERS - What They Are, How They Work, How Electricians Size Them; Author: Electrician U;https://www.youtube.com/watch?v=tXPy4OE7ApE;License: Standard Youtube License