Question
Chapter 38, Problem 9RQ
To determine
The reason that causes the motor to de energize after the motor reaches the full run voltage.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
1. What will be the output voltage during the positive half cycle of the input voltage?
2. What will be the output voltage during the negative half cycle of the input voltage?
Chapter 38 Solutions
EBK 3N3-EBK: INDUSTRIAL MOTOR CONTROL
Ch. 38 - Prob. 1RQCh. 38 - Explain the differences between open and closed...Ch. 38 - Prob. 3RQCh. 38 - Refer to the circuit shown in Figure 382. Assume...Ch. 38 - Prob. 5RQCh. 38 - Prob. 6RQCh. 38 - Prob. 7RQCh. 38 - Refer to the circuit shown in Figure 385. Explain...Ch. 38 - Prob. 9RQCh. 38 - Refer to the circuit shown in Figure 38–5. Assume...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Refer to the schematic diagram in Figure 318. Assume that the motor is not running. When the third speed push button is pressed, the motor starts in its lowest speed. After a delay of 3 seconds, the motor accelerates to second speed and 3 seconds later to third speed. After a period of about 1 minute, the fourth speed push button is pressed, but the motor does not accelerate to fourth speed. Which of the following could cause this problem? a. Control relay CR2 coil is open. b. S2 contactor coil is open. c. CR3 coil is shorted. d. S3 contactor coil is open.arrow_forwardExplain how to set the neutral plane position by using the compensating winding.arrow_forwardRefer to the circuit shown in Figure 255. Explain the steps necessary for coil S2 to energize.arrow_forward
- Refer to the circuit shown in Figure 5-29. In this circuit, the HR contactor is equipped with five contacts. Three are load contacts and two are auxiliary contacts. From looking at the schematic diagram, how is it possible to identify which contacts are the load contacts and which are the auxiliary contacts? Figure 5-29 The contactor contains both load and auxiliary contacts.arrow_forwardA large motor has a full load current rating of 425 amperes. Current transformers with a ratio of 600:5 are used to reduce the current to the overload heaters. What should be the full load current rating of the overload heaters?arrow_forwardRefer to the circuit shown in Figure 7-10. If wire number 11 were disconnected at the normally open auxiliary M contact, how would the circuit operate? Figure 7-10 Numbers are placed beside all components.arrow_forward
- Assume that all three motors shown in Figure 12–14 are running. Now assume that the STOP button is pressed and motors #1 and #2 stop running, but motor #3 continues to operate. Which of the following could cause this problem? STOP button is shorted. The 2M contact between wire numbers 31 and 32 is hung closed. The 3M load contacts are welded shut. The normally open 3M contact between wire numbers 23 and 31 is hung closed.arrow_forwardWhat is the function of the compensating winding?arrow_forwardRefer to the circuit shown in Figure 33–7. When the low speed push button is pressed, the motor begins to run in low speed. When the high speed push button is pressed, the motor stops running. Which of the following could cause this problem? The 1L contactor coil is open. H contactor coil is open. PR relay coil is open. The 2L contactor coil is open.arrow_forward
- Refer to the circuit shown in Figure 97. Assume that when the forward push button is pressed the motor does not start, but when the reverse push button is pressed the motor will start in the reverse direction. When the stop button is pressed the motor stops running. Which of the following could NOT cause this problem? a. The forward push button is defective. b. The F starter coil is open. c. The overload auxiliary contact is open. d. The normally closed R contact is open.arrow_forwardRefer to the transformer shown in Figure 5-13 to answer the following questions. What is the turns ratio of the winding between points B and E as compared to the winding between points D and E? Figure 5-13 Autotransformer practice problems.arrow_forwardRefer to the schematic in Figure 7-10. Assume that when the START button is pressed, the control transformer fuse blows. What is the most likely cause of this trouble? Figure 7-10 Numbers are placed beside all components.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningElectrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning