Chapter 4, Problem 4.49P
To determine
The value of capacitance to neutral in F/m and capacitive reactance.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
A Three-phase transposed line is composed of one conductor per phase with flat horizontal spacing of D = 14 meters, as shown in the below figure. The conductors have a diameter of 2.6 cm and
a GMR of 1.012 cm. Find the capacitance per phase per kilometer of the line.
a
C
D
D
2D
Select one:
O a 0.0088 microF/Km
Ob. 0.0077 microF/Km
Oc 1.455 microF/Km
Od. None of these
A three phase transposed line has a flat horizontal conductor configuration as shown
in the figure. The conductors have a diameter of 3.4 cm and a GMR of 1.35 cm.
Find the inductance and capacitance per phase per kilometer of the line.
-D =1.2 m
-D = 1.2 m ·
-2D = 2.4 m-
3. A balanced current is flowing in a three-phase balanced line. If the self-inductance and
mutual inductance of each phase are L, M[mH] respectively, if a current of I[A] flows
through phase a, what is the voltage drop generated in this line? However, the frequency
is f[H], it is completely connected, it is a single conductor line, and the resistance
component is ignored.
Chapter 4 Solutions
POWER SYS. ANALYSIS+DESIGN
Ch. 4 - ACSR stands for Aluminum-clad steel conductor...Ch. 4 - Overhead transmission-line conductors are bare...Ch. 4 - Alumoweld is an aluminum-clad steel conductor....Ch. 4 - EHV lines often have more than one conductor per...Ch. 4 - Shield wires located above the phase conductors...Ch. 4 - Conductor spacings, types, and sizes do have an...Ch. 4 - A circle with diameter Din.=1000Dmil=dmil has an...Ch. 4 - An ac resistance is higher than a dc resistance....Ch. 4 - Prob. 4.9MCQCh. 4 - Transmission line conductance is usually neglected...
Ch. 4 - Prob. 4.11MCQCh. 4 - Prob. 4.12MCQCh. 4 - For a single-phase, two-wire line consisting of...Ch. 4 - For a three-phase three-wire line consisting of...Ch. 4 - For a balanced three-phase positive-sequence...Ch. 4 - A stranded conductor is an example of a composite...Ch. 4 - lnAk=lnAk True FalseCh. 4 - Prob. 4.18MCQCh. 4 - Expand 6k=13m=12Dkm.Ch. 4 - Prob. 4.20MCQCh. 4 - For a single-phase two-conductor line with...Ch. 4 - In a three-phase line, in order to avoid unequal...Ch. 4 - For a completely transposed three-phase line...Ch. 4 - Prob. 4.24MCQCh. 4 - Does bundling reduce the series reactance of the...Ch. 4 - Does r=e14r=0.788r, which comes in calculation of...Ch. 4 - In terms of line-to-line capacitance, the...Ch. 4 - For either single-phase two-wire line or balanced...Ch. 4 - Prob. 4.29MCQCh. 4 - Prob. 4.30MCQCh. 4 - Prob. 4.31MCQCh. 4 - Prob. 4.32MCQCh. 4 - Prob. 4.33MCQCh. 4 - Prob. 4.34MCQCh. 4 - The affect of the earth plane is to slightly...Ch. 4 - When the electric field strength at a conductor...Ch. 4 - Prob. 4.37MCQCh. 4 - Prob. 4.38MCQCh. 4 - Considering two parallel three-phase circuits that...Ch. 4 - The Aluminum Electrical Conductor Handbook lists a...Ch. 4 - The temperature dependence of resistance is also...Ch. 4 - A transmission-line cable with a length of 2 km...Ch. 4 - One thousand circular mils or 1 kcmil is sometimes...Ch. 4 - A 60-Hz, 765-kV, three-phase overhead transmission...Ch. 4 - A three-phase overhead transmission line is...Ch. 4 - If the per-phase line loss in a 70-km-long...Ch. 4 - A 60-Hz, single-phase two-wire overhead line has...Ch. 4 - Prob. 4.9PCh. 4 - A 60-Hz, three-phase three-wire overhead line has...Ch. 4 - Prob. 4.11PCh. 4 - Find the inductive reactance per mile of a...Ch. 4 - A single-phase overhead transmission line consists...Ch. 4 - Prob. 4.14PCh. 4 - Find the GMR of a stranded conductor consisting of...Ch. 4 - Prob. 4.16PCh. 4 - Determine the GMR of each of the unconventional...Ch. 4 - A 230-kV, 60-Hz, three-phase completely transposed...Ch. 4 - Prob. 4.19PCh. 4 - Calculate the inductive reactance in /km of a...Ch. 4 - Rework Problem 4.20 if the bundled line has (a)...Ch. 4 - Prob. 4.22PCh. 4 - Prob. 4.23PCh. 4 - Prob. 4.24PCh. 4 - For the overhead line of configuration shown in...Ch. 4 - Prob. 4.26PCh. 4 - Figure 4.34 shows double-circuit conductors'...Ch. 4 - For the case of double-circuit, bundle-conductor...Ch. 4 - Prob. 4.29PCh. 4 - Figure 4.37 shows the conductor configuration of a...Ch. 4 - Prob. 4.32PCh. 4 - Prob. 4.33PCh. 4 - Prob. 4.34PCh. 4 - Prob. 4.35PCh. 4 - Prob. 4.36PCh. 4 - Prob. 4.38PCh. 4 - Calculate the capacitance-to-neutral in F/m and...Ch. 4 - Prob. 4.40PCh. 4 - Prob. 4.41PCh. 4 - Prob. 4.42PCh. 4 - Three ACSR Drake conductors are used for a...Ch. 4 - Consider the line of Problem 4.25. Calculate the...Ch. 4 - Prob. 4.45PCh. 4 - Prob. 4.46PCh. 4 - Prob. 4.47PCh. 4 - The capacitance of a single-circuit, three-phase...Ch. 4 - Prob. 4.49PCh. 4 - Prob. 4.50PCh. 4 - Prob. 4.51PCh. 4 - Approximately how many physical transmission...Ch. 4 - Prob. BCSQCh. 4 - Prob. CCSQCh. 4 - Prob. DCSQ
Knowledge Booster
Similar questions
- A three phase transposed line is composed of three conductor bundle. The conductors have a diameter of 2.1793 cm and a GMR (r) of 0.8839 cm. The spacing between the conductors in the bundle is 45 cm, and the GMD-18.8988 m. a b 0,0 45- O 0,0 I D D H 2D and the capacitance per phase is C then the GMRC of the line isarrow_forwardQUESTION 2.3 Find the capacitance to neutral for the signal-circuit, three-phase, 345-kV line with conductors having an outside diameter of 1.075 in. with phase configuration forming an "H” system (i.e., a horizontal phase configuration). The adjacent phase separation of the conductors is 20.0 ft. A 20.0 ft B Figure 2. 20.0 ft Carrow_forwardA single phase line has two parallel conductors 2m apart. The diameter of each conductor is 1.2 cm. Calculate the loop inductance/ phase/ kmoftheline.arrow_forward
- A 5 km long, 3-phase 34.5 kV line has a horizontal configuration of 4 ft. spacing. The conductor is 336.4 ACSR with GMR of 0.0244. What is the inductance of the line? * A. 7.63 mH B. 4.76 mH C. 5.33 mH D. 6.49 mHarrow_forwardA single-phase transmission line consisting of two conductors, the radius of each conductor is 0.4 cm, the distance between the conductors is three and half meters and the height above ground is eight 1-The capacitance in uF/km without effect of ground is 2-The capacitance in pF/km with effect of ground isarrow_forwardA. A 200 km line has a resistance of the line per phase per km is 0.08 ohm, a suceptance per phase per km = 6 x 10°-6 ohm and a reactance per phase per km is 0.8 ohm. Using nominal T method, determine the constant B of the line. A. 153.2 cis 84.6° C. 178.4 cis 81.5° B. 145.2 cis 88.2° D. 169.5 cis 83.6° B) A 132-KV, 50 Hz, 3-phase transmission line delivers a load of 50 MW at 0.8 pf lagging at receiving end. The generalized constant of the line are A = D = 0.95/1.4°; B = 96/7.8°; C= 0.0015/90°. Find the regulation of the line. A. 23.8 %. C. 29.4 % B. 25.6 %. D. 27.1 %arrow_forward
- Please in 15 minutes VERY EASY! Line conductors with 3-phase, 50Hz, “68” kV values are positioned horizontally as shown in the figure. The diameter of the conductors is “1.29” cm and the line length is “110” km. Find the following according to these values? (ε0=8*854*10-12F/m) a-) Find the capacitance value of a phase? b-) Find the capacitive reactance value of a phase? c-) Find the current value that will flow from a single phase line? (charge current, using Capacitive reactance)arrow_forwardDetermine the inductance per km per phase of a single circuit 460 KV line using two bundle conductors per phase as shown in the figure. The diameter of each conductor is 5 cm. 40cm 6.5m 6.5m 13marrow_forwardA 60-Hz, single-phase two-wire overhead line has solid cylindrical copper conductors with a 1.5 cm diameter. The conductors are arranged in a horizontal configuration with 0.5 m spacing. Calculate in mH/km (a) the inductance of each conductor due to internal flux linkages only, (b) the inductance of each conductor due to both internal and external flux linkages, and (c) the total inductance of the line.arrow_forward
- The three conductors of a three-phase line are arranged at the corners of a triangle of sides 7 m, 15 m, and 9 m. The diameter of each line conductor is 5 cm. Calculate(i) Inductance per phase per km in mH Inductance per phase per km in mHarrow_forward3. Find the capacitance per unit length of the single-phase line shown below. Conductors a, b, c are of 0.2 cm radius, and conductors d and e are of 0.4 cm radius. Oa 4m Oe 6ide X Side Yarrow_forwardA. For the following figure, the diameter of each conductor is 2.5 cm. Find the inductance and capacitance per km per phase. 40 cm 40 cm 40 cm a a' b' 10 m 10 m Phase A Phase B Phase C B. A 3-ph transmission line has 3 conductors b, spaced at the corners of an equilateral triangle of 350 cm side. Each conductor has 1.2 cm diameter. 1. Find the inductance per phase. 2. If the line is constructed with horizontal spacing with suitably transposed conductors, find the spacing between the first and last conductors which would give the same value of inductance as in the equilateral arrangement.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS