Check out a sample textbook solutionStudents have asked these similar questions
A 60 Hz, three-phase, transposed transmission line, is designed with three bobolink conductors per phase, in horizontal
arrangement as shown in the figure below. Distance between consecutive phases is D = 6.2 m and distance among bundle
conductors is h =0.5m. Each conductor has a radius of 18 mm and a GMR of 14.39mm. The per phase resistance is
1.677x10-5 2/m.
r= 18 mm
GMR= 14.39 mm
a
b
h
D
D
The per phase shunt admittance assuming zero conductance in µO/km is:
О a., 5.4347
O b. j5.3316
О с /4.2266
O d. j4.0973
O e. 59630.2922 + j10.9770
12. There are 6 conductors in a double circuit
line. Each conductor has a radius of 12 mm.
The 6conductors are arranged horizontally.
The center to center distance between the
conductor is 2m. The sequence of conductors
are from left to right as follows: a,b.c,a', b', c'.
Calculate the inductance per km per phase of
system.
the
a'
2 m
2 m
2 m
2 m
2 m
Find the GMR of this conductor as r.( Need handwritten solution only please otherwise downvote)
Chapter 4 Solutions
POWER SYS. ANALYSIS+DESIGN
Ch. 4 - ACSR stands for Aluminum-clad steel conductor...Ch. 4 - Overhead transmission-line conductors are bare...Ch. 4 - Alumoweld is an aluminum-clad steel conductor....Ch. 4 - EHV lines often have more than one conductor per...Ch. 4 - Shield wires located above the phase conductors...Ch. 4 - Conductor spacings, types, and sizes do have an...Ch. 4 - A circle with diameter Din.=1000Dmil=dmil has an...Ch. 4 - An ac resistance is higher than a dc resistance....Ch. 4 - Prob. 4.9MCQCh. 4 - Transmission line conductance is usually neglected...
Ch. 4 - Prob. 4.11MCQCh. 4 - Prob. 4.12MCQCh. 4 - For a single-phase, two-wire line consisting of...Ch. 4 - For a three-phase three-wire line consisting of...Ch. 4 - For a balanced three-phase positive-sequence...Ch. 4 - A stranded conductor is an example of a composite...Ch. 4 - lnAk=lnAk True FalseCh. 4 - Prob. 4.18MCQCh. 4 - Expand 6k=13m=12Dkm.Ch. 4 - Prob. 4.20MCQCh. 4 - For a single-phase two-conductor line with...Ch. 4 - In a three-phase line, in order to avoid unequal...Ch. 4 - For a completely transposed three-phase line...Ch. 4 - Prob. 4.24MCQCh. 4 - Does bundling reduce the series reactance of the...Ch. 4 - Does r=e14r=0.788r, which comes in calculation of...Ch. 4 - In terms of line-to-line capacitance, the...Ch. 4 - For either single-phase two-wire line or balanced...Ch. 4 - Prob. 4.29MCQCh. 4 - Prob. 4.30MCQCh. 4 - Prob. 4.31MCQCh. 4 - Prob. 4.32MCQCh. 4 - Prob. 4.33MCQCh. 4 - Prob. 4.34MCQCh. 4 - The affect of the earth plane is to slightly...Ch. 4 - When the electric field strength at a conductor...Ch. 4 - Prob. 4.37MCQCh. 4 - Prob. 4.38MCQCh. 4 - Considering two parallel three-phase circuits that...Ch. 4 - The Aluminum Electrical Conductor Handbook lists a...Ch. 4 - The temperature dependence of resistance is also...Ch. 4 - A transmission-line cable with a length of 2 km...Ch. 4 - One thousand circular mils or 1 kcmil is sometimes...Ch. 4 - A 60-Hz, 765-kV, three-phase overhead transmission...Ch. 4 - A three-phase overhead transmission line is...Ch. 4 - If the per-phase line loss in a 70-km-long...Ch. 4 - A 60-Hz, single-phase two-wire overhead line has...Ch. 4 - Prob. 4.9PCh. 4 - A 60-Hz, three-phase three-wire overhead line has...Ch. 4 - Prob. 4.11PCh. 4 - Find the inductive reactance per mile of a...Ch. 4 - A single-phase overhead transmission line consists...Ch. 4 - Prob. 4.14PCh. 4 - Find the GMR of a stranded conductor consisting of...Ch. 4 - Prob. 4.16PCh. 4 - Determine the GMR of each of the unconventional...Ch. 4 - A 230-kV, 60-Hz, three-phase completely transposed...Ch. 4 - Prob. 4.19PCh. 4 - Calculate the inductive reactance in /km of a...Ch. 4 - Rework Problem 4.20 if the bundled line has (a)...Ch. 4 - Prob. 4.22PCh. 4 - Prob. 4.23PCh. 4 - Prob. 4.24PCh. 4 - For the overhead line of configuration shown in...Ch. 4 - Prob. 4.26PCh. 4 - Figure 4.34 shows double-circuit conductors'...Ch. 4 - For the case of double-circuit, bundle-conductor...Ch. 4 - Prob. 4.29PCh. 4 - Figure 4.37 shows the conductor configuration of a...Ch. 4 - Prob. 4.32PCh. 4 - Prob. 4.33PCh. 4 - Prob. 4.34PCh. 4 - Prob. 4.35PCh. 4 - Prob. 4.36PCh. 4 - Prob. 4.38PCh. 4 - Calculate the capacitance-to-neutral in F/m and...Ch. 4 - Prob. 4.40PCh. 4 - Prob. 4.41PCh. 4 - Prob. 4.42PCh. 4 - Three ACSR Drake conductors are used for a...Ch. 4 - Consider the line of Problem 4.25. Calculate the...Ch. 4 - Prob. 4.45PCh. 4 - Prob. 4.46PCh. 4 - Prob. 4.47PCh. 4 - The capacitance of a single-circuit, three-phase...Ch. 4 - Prob. 4.49PCh. 4 - Prob. 4.50PCh. 4 - Prob. 4.51PCh. 4 - Approximately how many physical transmission...Ch. 4 - Prob. BCSQCh. 4 - Prob. CCSQCh. 4 - Prob. DCSQ
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- What are the colors of the conductors in nonmetallic-sheathed cable for a. 2-wire cable? _______________, _______________ b. 3-wire cable? _______________, _______________, _______________arrow_forwardA 230-kV, 60-Hz, three-phase completely transposed overhead line has one ACSR 954 kcmil conductor per phase and flat horizontal phase spacing, with 7 m between adjacent conductors Determine the inductance in H/m and the inductive reactance in /km.arrow_forwardSingle core cable design for 25 kV. The radius of conductor is 0.5 cm. The insulation material consists of two layers. The thickness of each layer is 2 cm. The voltage of first and second layers are 20 kV, 5 kV respectively. The minimum Electric stress of the cable is *arrow_forward
- Single core cable design for 25 kV. The radius of conductor is 0.5 cm. The insulation material consists of two layers. The thickness of each layer is 2 cm. The voltage of first and second layers are 20 kV, 5 kV respectively. The minimum Electric stress of the cable is * 9.45 kV/cm 1.89 kV /cm O 1.25 kV/cm 5.78 kV/cm Non of themarrow_forwardSingle core cable design for 25 kV. The radius of conductor is 0.5 cm. The insulation material consists of two layers. The thickness of each layer is 2 cm. The voltage of first and second layers are 20 kV, 5 kV respectively. The maximum Electric stress of the cable isarrow_forwardSome electricians do not bother to calculate the minimum size of neutral service conductor. They size the minimum ungrounded conductor size and then use this information to determine the minimum neutral conductor size. Explain how they determine the minimum neutral size using the minimum ungrounded conductor sizarrow_forward
- 3-phase single circuit bundled conductor line with two sub-conductors per phase has horizontalspacing with 6.1 m between the centre lines of adjacent phases. The distance between the subconductorsof each phase is 30.5 cm and each sub-conductor has a diameter of 2.54 cm. Find theinductance per phase per km. [0.988 mh]arrow_forwardA set of conductors is used to supply residential unit with a total load current of 60 A at a single-phase supply voltage of 230 V. What would be the minimum size of the conductor to be used to achieve at least 5% voltage drop? The total conductor length is 300 ft. ..arrow_forwardA two-wire DC splitter of 1Km length and resistance of each conductor (m/00030.0) and feeds the loads as shown in the augmented form: 1. Minimum voltage point on the conductor 2. The voltage at each load point 400V 200m 300m 400m 100m 80A 60A 10A SOAarrow_forward
- The three bus-bar conductors in an outdoor sub-station are supplied by units of post insulators. Each unit consists of a stack of 3-pin insulators fixed one on the top of the other. The voltage across the lowest insulator is 8-45 kV and that across the next is 7-25 kV. Find the bus-bar voltage of the station.arrow_forwardThe figure shows a common spacing for a 345 kV line using ACSR Drake conductors in bundles of two conductors with a bundle spacing d = 18 in and distances as shown. Calculate: (a) the line-to-neutral capacitance per mile, (b) the line-to-neutral capacitive susceptance per mile, (c) the per phase inductance per mile, and (d) the per phase inductive reactance per mile. 18" 7' 18" 18" 24' 24'arrow_forwardDiscuss the desirable properties of insulators. Explain the causes of insulator failure due to electrical breakdown. Each line of a three-phase system is suspended by a string of three identical insulators of self-capacitance C farad. The shunt capacitance of connecting metal work of each insulator to earth is 20.7 % of C while for line it is 13.8 % of C. Calculate the string efficiency of the system if a guard ring increases the capacitance to the line of metal work of the lowest insulator to 0.25 C.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage LearningEBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
How do Electric Transmission Lines Work?; Author: Practical Engineering;https://www.youtube.com/watch?v=qjY31x0m3d8;License: Standard Youtube License