Question
Chapter 4, Problem 4.8QAP
Interpretation Introduction
(a)
Interpretation:
The maximum uncertainty in digitization for the 8-bit ADC converter is to be determined.
Concept introduction:
Maximum uncertainty in digitization of ADCs of
Interpretation Introduction
(b)
Interpretation:
The maximum uncertainty in digitization for the 8-bit ADC converter is to be determined.
Concept introduction:
Maximum uncertainty in digitization of ADCs of
Interpretation Introduction
(c)
Interpretation:
The maximum uncertainty in digitization for the 8-bit ADC converters is to be determined.
Concept introduction:
Maximum uncertainty in digitization of ADCs of
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
1.4
A 6.25 x 10-³ M solution of potassium permanganate (KMnO4) has a transmittance of
47.4% when measured in a 1.5 cm cell at a wavelength of 625 nm.
(a) Calculate the absorbance of the KMnO4 solution
(b) Calculate the molar absorptivity of KMnO4
The validation process comprises four main steps that are : hardware validation, software validation, method validation and system suitability. To evaluate a spectrophotometer’s accuracy by measuring absorbance, a solution of 60.06 mg/L K2Cr2O7 in 0.0050M H2SO4 was carefully prepared together with a 0.0050 M H2SO4 as a reagent blank. If the spectrometer’s signal is properly calibrated, it has been reported that this solution should provide an absorbance of 0.640 +- 0.010 at wavelength 350 nm. Which one of the validations mentioned above had been involved in this process? Explain your choice
1-31. We shall learn when we study molecular spectroscopy that heteronuclear diatomic
molecules absorb radiation in the microwave region and that one determines directly the
so-called rotational constant of the molecule defined by
B =
8721
where I is the moment of inertia of the molecule. Given that B = 3.13 × 105 MHz for H35C1,
calculate the internuclear separation for H35C1. The atomic mass of H and 35C1 are 1.008
and 34.97, respectively.
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- Paylbenarrow_forwardYou have two solutions containing the same compound having the same pink color. The concentration of the first solution is 2.0 M, while the concentration of the other solution is 2.5 M. Absorbance of each solution was measured with the same spectrophotometer at the same wavelength. (A) Which solution has the more intense pink color? (B) Which solution has the higher absorbance?arrow_forwardIn order to measure riboflavin in a breakfast cereal, a 5.00-gram sample of the cereal was extracted with acetic acid and filtered. The extract was transferred to a 50.0 mL volumetric flask and diluted to the mark. The sample was transferred to a cuvette and the fluorescence was measured. The instrument read 59 units (Fluorescence units –an arbitrary scale). 24.00 mL of the cereal extract was sample was mixed with 1.0 mL of a riboflavin standard that was 0.500 ug/mL. The fluorescence of this mixture was measured and read 94 fluorescence units. Calculate the concentration of riboflavin per gram of cereal (use µg/gram of cereal).arrow_forward
- 3. The change in frequency produced by the Doppler shift when a sound source of frequency f is moving with velocity v toward a fixed observer is given by fv Af (u-v) and v and their uncertainties, calculate Af and its uncertainty. Which, if any, of where u is the velocity of sound. From the following values of u, f, the uncertainties make a negligible contribution to the uncertainty in Af ? u = (332 ± 8) m s1; f = (1000 ± 1) Hz; and v = (0.123 ± 0.003) m s1arrow_forwardExplain the difference between molecular mass and nominal mass. Give the value of the molecular mass and nominal mass of benzene, C6H6.arrow_forwardFind the uncertainty ox in x as a function of the uncertainties ou and oy in u and v for the following functions: (u+v) (а) х %3 2 (b) x =uv? (c) x= u? +v?arrow_forward
- A beam of electrons with a speed of 600 m/s passes through double slit with the slits spaced 2 μm apart. If the detector is 2 meters away from the double slit, how far off the center will the m = 1 signal appear?arrow_forward9) Using error propagation formulas, find (i) the absolute uncertainty and (ii) the percent relative uncertainty for each of the following operations. (a) 6.1 (+0.3) – 3.6 (±0.2) = ? (b) 9.56 (+0.06)X 0.017 (+0.002) = ? (c) [6.9 (±0.3) – 3.9 (±0.2)] ÷ 9.32 (±0.04) = ? (d) 8.24 (+0.06)X {[6.9 (±0.3) X 10-3] + [4.2 (±0.2) X 10-3]} = ?arrow_forwardSuppose a student is preparing a set of standard solutions for use in a spectrophotometric study. If percent transmittance, %T, were measured in the standard solutions before the color had a chance to fully develop, the measured value would be compared with solutions that have allowed the color to fully develop.arrow_forward
- Match the items in the left-hand column to the items in the right-hand column by writing the appropriate letter in the blank. Each is used only once. (a) The intensity of light after having passed through a solution of an absorbing species. (b) A = abc (c) Molar absorptivity (d) Pathlength (c) I/I, (f) -log T _T Beer's law (g) The intensity of light after having passed through a blank solution. %T (h) Absorptivity (i) T × 100arrow_forward1arrow_forwardMany ions form colored solutions when dissolved in water. For example, aqueous Cu2+ solutions are light blue and aqueous Ni2+ solutions look light green. These metals in particularare often found in stainless steel. Would you expect their presence in your samples to interfere in the spectrophotometric analysis of permanganate at 525 nm? Why or why not? I think the answer is that I would expect the Cu2+ in my samples to interfere but not Ni2+ because the Ni2+ is green, signifying a higher wave length that the spectrometer wouldn't be able to pick up on because it was only set to 525 (blue-ish) where as the green is 530-ish. I just want to make sure thanks!arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningPrinciples of Modern ChemistryChemistryISBN:9781305079113Author:David W. Oxtoby, H. Pat Gillis, Laurie J. ButlerPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Principles of Modern Chemistry
Chemistry
ISBN:9781305079113
Author:David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:Cengage Learning