Electric Motor Control
10th Edition
ISBN: 9781133702818
Author: Herman
Publisher: CENGAGE L
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 40, Problem 4SQ
When the rotor and stator fields lock into step, why may the reading of the AC ammeter decrease?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
What will happen if the back emf drops to zero because the external mechanical load stops the armature from rotating?
A shunt generator has 284 Volts. When field current increased greater than rated current what will be the excitation voltage of the Generator?
explain any one method of speed control of Induction motor with respect to rotor side with diagram. please i need with clear handwriting because i send the quation befor but some word not clear and i cannot be read.thanks
Chapter 40 Solutions
Electric Motor Control
Ch. 40 - What are the two basic functions of synchronous...Ch. 40 - Prob. 2SQCh. 40 - If all of the control circuits are ACand DC is not...Ch. 40 - When the rotor and stator fields lock into step,...Ch. 40 - Prob. 5SQCh. 40 - Prob. 6SQCh. 40 - In Figure 402, approximately what is the...Ch. 40 - Why are the AC ammeter and DC meter necessary in...Ch. 40 - Prob. 9SQ
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Is true that the DC supply is applied to the rotor windings of a synchronous motor?arrow_forwardA 10kW, 4-pole lap wound, dc shunt generator has a useful flux per pole of0.075 Wb. The armature consist a total of 500 conductors. Calculate theterminal voltage when running at 900 rpm if the armature current and shuntfield resistances are 0.5 ohms and 50 ohms.arrow_forwardA 10kW, 4-pole lap wound, dc shunt generator has a useful flux per pole of0.075 Wb. The armature consist a total of 500 conductors. Calculate theterminal voltage when running at 900 rpm if the armature current and shuntfield resistances are 0.5 and 50 .arrow_forward
- An 8-Pole, simplex lap wound, shunt generator has 800conductors and a flux per pole of 0.025Wb. The armature and shunt field resistances are 1ohms and 45ohms respectively. If a resistance of 11.25ohms is connected as load and the machine is running at 800rpm. Calculate the terminal voltage (in Volts).arrow_forwardSquirrel-cage asynchronous motor, which has never been used before, as a generator in its first use will be run. Does the machine work as a generator? Explain.arrow_forwardWhy small voltage is built up immediately in rotating shunt machine eve without field excitation?arrow_forward
- A 3 phase, 4 pole, 60 Hz induction motor is running at a speed of 1720 rpm. Input power to the motor is 15 kW. Assuming stator loss to be zero, what is the value of rotor copper loss?arrow_forwardWhen the armature current of a 220 Volt DC shunt motor is 40 Amperes, when the magnetic flux suddenly decreases by 10%, armature current increases to 80 Amper, which is the armature winding resistance of the motor?arrow_forwardThe armature of a 4-pole, 130 slots shunt generator is lap wound with four conductors per slot. The flux per pole is 80 mWb. The armature and shunt field resistances are 0.04 Ω and 50 Ω respectively. Determine the speed of the machine when supplying 400 A at a terminal voltage of 250 V.arrow_forward
- Explain No load test or rotational loss test and Blocked rotor test.arrow_forwardAn 8-Pole, simplex lap wound, shunt generator has 800conductors and a flux per pole of 0.025Wb. The armature and shunt field resistances are 1ohms and 45ohms respectively. If a resistance of 11.25ohms is connected as load and the machine is running at 800rpm. Calculate the terminal voltage (in Watts)arrow_forwardWhy must a synchronous motor never be started when DC excitation is applied to the rotatorarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
Electrical Measuring Instruments - Testing Equipment Electrical - Types of Electrical Meters; Author: Learning Engineering;https://www.youtube.com/watch?v=gkeJzRrwe5k;License: Standard YouTube License, CC-BY
01 - Instantaneous Power in AC Circuit Analysis (Electrical Engineering); Author: Math and Science;https://www.youtube.com/watch?v=If25y4Nhvw4;License: Standard YouTube License, CC-BY