Textbook Question
Chapter 49, Problem 3RQ
A motor is tripping out on overload. The motor nameplate reveals a full-load current of 68 amperes. When the motor is operating under load, an ammeter indicates the following: Phase 1 = 106 amperes, Phase 2 = 104 amperes, and Phase 3 = 105 amperes. What is the most likely problem with this motor?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
what is the mechanical power developed by a motor that turns at 2500 rpm and has a torque of 4 Nm
What is the minimum pulley diameter for a 1 HP motor running at 1750 RPM?
Chapter 49 Solutions
Industrial Motor Control
Ch. 49 - Prob. 1RQCh. 49 - What is the advantage of a plunger-type voltage...Ch. 49 - A motor is tripping out on overload. The motor...Ch. 49 - A motor is tripping out on overload. The motor...Ch. 49 - Prob. 5RQCh. 49 - Refer to the circuit shown in Figure 4916. Assume...Ch. 49 - Prob. 7RQCh. 49 - Refer to the circuit shown in Figure 49–20. Assume...Ch. 49 - Prob. 9RQCh. 49 - Refer to the circuit shown in Figure 4920. Assume...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A motor nameplate lists the voltage as 208–230/460. The nameplate also lists the full-load amps as 34.2–31.6/15.8. If the motor is operated at 240 volts, what should be the full-load current?arrow_forwardAssume that a nine-lead dual-voltage motor is being tested with an ohmmeter. The meter indicates resistance values as follows: T7–T8 = 6Ω, T7–T9 = 6Ω, and T8–T9 = 10Ω. What would these readings indicate?arrow_forwardWhat is the advantage of the capacitor-start induction-run motor over the resistance-start induction-run motor?arrow_forward
- What is the full-load running current of a three-phase, 50-hp motor connected to a 560-volt line? What are the minimum size NEMA and IEC starters that should be used to connect this motor to the line?arrow_forwardWhen a repulsion-start induction-run motor reaches about 75% of rated full-load speed, it stops operating as a repulsion motor and starts operating as a squirrel-cage motor. What must be done to cause the motor to begin operating as a squirrel-cage motor?arrow_forwardWhat is the advantage of a capacitor start induction run motor over a resistance start induction run motor?arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningElectrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Mod-01 Lec-16 Basics of Instrumentation; Author: nptelhrd;https://www.youtube.com/watch?v=qbKnW42ZM5c;License: Standard YouTube License, CC-BY