Chapter 5, Problem 7RQ
A 480-volt three-phase load is rated at 34.5 kVA. It is to be supplied with variable three-phase voltage. Because the load is continuous, the transformers ratings are to be increased by 1.25% of the rated load. Three variable autotransformers are used to supply this load. Refer to Table 4-2 and determine the standard size of each transformer that should be used to make this connection.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A six-pole lap wound armature rotating at 350 rpm is required to generate 260 V. The effective flux per pole is about 0.05 Wb. If the armature has 120 slots, determine the suitable number of conductors per slot and hence determine the actual value of flux required to generate the same voltage
A 3-phase, 50 Hz, 3000 V motor develops 600 H.P. (447·6 kW), the power factor being 0·75 lagging andthe efficiency 0·93. A bank of capacitors is connected in delta across the supply terminals and powerfactor raised to 0·95 lagging. Each of the capacitance units is built of five similar 600-V capacitors.Determine the capacitance of each capacitor.
Chapter 5 Solutions
Electrical Transformers and Rotating Machines
Ch. 5 - An AC power source is connected across 325 turns...Ch. 5 - Is the transformer in question 1 a step-up or...Ch. 5 - Prob. 3RQCh. 5 - A load impedance of 52 Ω is connected to the...Ch. 5 - How much current will flow in the primary of the...Ch. 5 - Prob. 6RQCh. 5 - A 480-volt three-phase load is rated at 34.5 kVA....Ch. 5 - If the load in question 7 was supplied by two...Ch. 5 - Prob. 1PCh. 5 - Prob. 2P
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Two transformers rated at 100 kVA each are connected in an open-delta connection. What is the total output power that can be supplied by this bank?arrow_forwardRefer to the transformer shown in Figure 5-13 to answer the following questions. What is the turns ratio of the winding between points B and E as compared to the winding between points D and E? Figure 5-13 Autotransformer practice problems.arrow_forwardRefer to the transformer shown in Figure 5-13 to answer the following questions. The transformer shown in Figure 5-13 is supplying 325 volt amperes to a load. The primary voltage is 240 volts. What is the primary current? Figure 5-13 Autotransformer practice problems.arrow_forward
- Name three factors that determine the amount of induced voltage.arrow_forwardIf the secondary of the transformer in question 5 supplies a current of 9.6 amperes to a load, what is the primary current? (Disregard excitation current.)arrow_forwardA 10 kVA transformer has a primary voltage rating of 240 volts and a secondary voltage rating of 480 volts. The transformer is connected to a circuit protected by a 100 ampere circuit breaker. The secondary is protected by a 25-ampere fuse. Does the primary require separate overcurrent protection?arrow_forward
- If the load in question 7 is connected in a wye, what would be the line voltage and line current supplying the load?arrow_forwardIf the load in question 7 was supplied by two autotransformers connected in open delta, what would be the minimum standard size transformers that could be used to supply this load?arrow_forwardA load impedance of 52 Ω is connected to the secondary winding of the transformer in question 3. How much current will flow in the secondary?arrow_forward
- If a single-phase load is connected across the two line conductors and neutral of the transformer in question #2, and one line has a current of 80 amps and the other line has a current of 68 amps, how much current is flowing in the neutral conductor?arrow_forwardHow does the National Electrical Code specify that the high leg of a four-wire delta connection be marked?arrow_forwardAssume that a line voltage of 2400 volts is connected to the primary of the three-phase transformer and the line voltage of the secondary is 240 volts. What is the turns ratio of the transformer?arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Electrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage LearningUnderstanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Fluid Mechanics - Viscosity and Shear Strain Rate in 9 Minutes!; Author: Less Boring Lectures;https://www.youtube.com/watch?v=_0aaRDAdPTY;License: Standard youtube license