Bundle: Understanding Motor Controls, 4th + Mindtap Electrical, 2 Terms (12 Months) Printed Access Card
4th Edition
ISBN: 9780357097755
Author: Stephen L. Herman
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 53, Problem 5RQ
To determine
The change that happens to the output and discharge pins of the 555 timer.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
In relation to the circuit presented below, mark the alternative(s) that you consider correct.
1 To enable actuator A2 to advance, it is necessary to switch valve V2 to the leftmost position and ensure that valve V1 is in its initial (intermediate) position.
2 Switching valve V2 to the leftmost position allows actuator A2 to advance, but for this to happen, valve V1 must also be switched to the leftmost position.
3 When activating valve V1, using the locking lever installed on the left side of it, the two actuators (A1 and A2) are allowed to advance.
4 Hydraulic pump B1 is a simple variable displacement type.
5 Valves V1 and V2 have a TANDEM center.
Name
Section 5-2: Line Diagrams-Signals,
Decisions, and Actions
In the following application, a temperature switch controls a heating contactor and a flow switch is used to
ensure there is enough air flow. If there is not enough air flow, an alarm is sounded. Complete the required
information.
1. List all the signal devices in the circuit.
2. List all the action devices in the circuit.
3. List the decision part of the circuit that automatically sounds the alarm if there is a problem.
4. When the heating element is on during normal operation, is the flow switch open or closed?
CIRCULATING
2
L1
FAN
TEMPERATURE
SWITCH
TR
HEATING
ELEMENTS
FLOW
SWITCH
-HOT AIR
PADDLE
AIR FILTER
NORMALLY CLOSED
FLOW SWITCH
65
ALARM
(SOUNDS IF NO FLOW FOR
15 SECONDS OR MORE)
Date
HEATING
CONTACTOR
TR
ON-DELAY
TIMER
SUPPLY AIR
COLD AIR
(3) TIME SET= 15 SEC
© 2014 American Technical Publishers, Inc.
All rights reserved
Based on the timing diagram below, choose the correct statement regarding Timer Relay.
On
Coil
Power
ff
+ 5 →
Seconds
Closed
Contact
Status
Open
Time
Select one or more:
O a. This is the OFF-Delay Relay
O b. This is the ON-Delay Relay
O c. The relay can used in automatic gate at car parking application :- when sensor detect car already pass
by to parking area, motor to control gate closing will turn ON after a few minutes.
O d. When the coil energized, the relay contact will make connection at the same timing.
Chapter 53 Solutions
Bundle: Understanding Motor Controls, 4th + Mindtap Electrical, 2 Terms (12 Months) Printed Access Card
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Refer to the circuit shown in Figure 25–5. Assume that timer TR1 is set for a delay of 10 seconds and timer TR2 is set for a delay of 5 seconds. When the START button is pressed, the motor starts. After 10 seconds the S1 contacts open and the motor continues to accelerate, but never reaches full speed. After a delay of about 30 seconds, the motor trips out on overload. Which of the following could cause this problem? TR1 coil is open. S2 coil is open. S1 coil is open. R coil is open.arrow_forwardRefer to the circuit shown in Figure 42–21. Assume that a fused jumper is connected across terminals 1 and 3 of TR2 timer. What would happen if the jumper were left in place and the FIRST SPEED push button pressed? The motor would start in its lowest speed and progress to second speed, but never increase to third speed. The motor would start operating immediately in third speed. The motor would not start. The motor would start in second speed and then increase to third speed.arrow_forwardRefer to the circuit shown in Figure 241. Assume that timer TR is set for a delay of 10 seconds. When the START button is pressed, the motor starts in low speed. After a delay of 30 seconds the motor is still in its lowest speed and has not accelerated to normal speed. Which of the following could not cause this condition? a. The START button is shorted. b. Timer coil TR is open. c. Contactor coil R is open. d. Timed contact TR did not close after a delay of 10 seconds.arrow_forward
- What are the two basic classifications of timers?arrow_forwardRefer to the circuit shown in Figure 247. Assume that all timers are set for a delay of 5 seconds. When the START button is pressed the motor starts in its lowest speed. After a delay of over 10 seconds, the motor is still running in the lowest speed. Which of the following could cause the problem? a. TR1 coil is open. b. TR1 coil is shorted. c. S2 coil is open. d. S1 coil is shorted.arrow_forwardRefer to the circuit shown in Figure 269. Assume that timer TR is set for a delay of 10 seconds. When the START button is pressed, the motor does not start. After a delay of 10 seconds, the motor suddenly starts with its stator windings connected in delta. Which of the following could cause this problem? a. TR timer coil is open. b. 2M contactor coil is open. c. S contactor coil is open. d. 1M starter coil is open.arrow_forward
- Refer to the circuit shown in Figure 26–9. Assume that timer TR is set for a delay of 10 seconds. When the START button is pressed, the motor starts with its windings connected in wye. After a period of 1 minute, the motor has not changed from wye to delta. Which of the following could cause this condition? TR timer coil is open. S contactor coil is open. 1M starter coil is open. The control transformer fuse is blown.arrow_forwardChapter 18 Controlling a Preumatic System 461 Timing volume reservoir Goodheart-Willcox Publisher Figure 18-31, Timing-volume reservoirs allow ontrol of the sequence of a circuit using pilot-activated directional control valves.arrow_forwardJ 6 Explain the operation of the circuit presented below. For each component, indicate name, drive mode, return mode, etc.arrow_forward
- Refer to the schematic diagram in Figure 318. Assume that the motor is not running. When the third speed push button is pressed, the motor starts in its lowest speed. After a delay of 3 seconds, the motor accelerates to second speed and 3 seconds later to third speed. After a period of about 1 minute, the fourth speed push button is pressed, but the motor does not accelerate to fourth speed. Which of the following could cause this problem? a. Control relay CR2 coil is open. b. S2 contactor coil is open. c. CR3 coil is shorted. d. S3 contactor coil is open.arrow_forwardIs timer TR an on-delay or off-delay timer?arrow_forwardThe forward and return strokes of the cylinder are to be controlled by separate push buttons. The speed of forward and return strokes is to be slow and separately adjustable. The cylinder diameter is 50mm and it has a 160mm. Draw the circuit diagram of this problem with completecomponent and port designation.arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningElectrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning